Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Renovation, building

My condition worsened in the mid- 80s when we moved into a newly-renovated building with new carpeting and other finishes, although I still didn t make the connection. I knew the chemical exposures were related to my coughing, but didn t understand the connection to my more serious chronic illness. [Pg.138]

The emission rates of formaldehyde and VOCs from most indoor decorating and refurbishing materials are highest in new or renovated buildings. These compounds can outgas (i.e., evaporate continuously) slowly over months or years. As a consequence, the indoor concentration of these compounds slowly decreases, as shown in Tables 8 and 9. However, it can be also seen from... [Pg.248]

Rothweiler H, Wager PA, Schlatter C. 1992. Volatile organic compounds and some very volatile organic compounds in new and recently renovated buildings in Switzerland. Fifth International Conference of Indoor Air Quality and Climate (Indoor Air 90) Characterization of Indoor Air, Toronto, Ontario, Canada, July 29- August 3, 1990. Atmos Environ Part A Gen Top 26(12) 2219-2225. [Pg.229]

In 1872, Schmiedeberg established his laboratories in a newly renovated building in Strassburg, which became the first well-equipped modern laboratory for pharmacology. As stated before, these new and up-to-date facilities attracted many of the brightest young... [Pg.12]

The rate of decay of VOC concentrations in new or renovated buildings will be a difficult factor to generalize about since it will depend on ... [Pg.177]

Plastic pipes are usually used for drain systems. PVC pipes are cut to a suitable length by a saw, installed with the help of lubricant to the muff piece, which has a rubber seal. PE pipes are joined by heating the ends of the pipes to 200 0. Glues are only rarely used in the installation of plastic pipes. Tools used for plastic pipes include saws and welding equipment. When renovating buildings, the plumbers have to remove old heat insulation, which is made of either mineral wool or, in older houses, asbestos. [Pg.1066]

An electrochemical cell is formed and the anodic metal dissolves. This can be corrected by applying a counter current or voltage or by introducing a more reactive, sacrificial anode, for example, adding magnesium alloy to the above Zn-Fe-Cu system, a procedure commonly used for hot-water pipes in renovated buildings. [Pg.180]

Identify aspects of planned projects that could affect indoor air quality and manage projects so that good air quality is maintained this includes redecorating, renovation, or remodeling, relocation of personnel or functions within the building, new construction. [Pg.207]

In addition, establish lines of communication for sharing information pertaining to equipment in need of repair or replacement, plans to remodel, renovate, or redecorate, new uses of building space or increases in occupant population, installation of new equipment. [Pg.207]

Outdoor air is generally less polluted than the system return air. However, problems with reentry of previously exhausted air occur as a result of improperly located exhaust and intake vents or periodic changes in wind conditions. Other outdoor contamination problems include contaminants from other industrial sources, power plants, motor vehicle exhaust, and dust, asphalt vapors, and solvents from construction or renovation. Also, heat gains and losses through the building envelope due to heat conduction through exterior walls, floor, and roof, and due to solar radiation and infiltration, can be attributed to effects from external sources. [Pg.418]

They are used to detect heat loss this is of importance in the renovation of old buildings. [Pg.61]

Buildings constructed between 1930 and 1950 may contain insulation made with asbestos. Wall and ceiling insulation that contains asbestos is generally found inside the wall or ceiling ( sandwiched behind plaster walls). The asbestos is used as material for thermal insulation, acoustical insulation, and fire protection. Renovation and home improvements may expose and disturb the materials. [Pg.87]

The notification requirements do not apply if a building owner plans renovation projects that will disturb less than the NESHAP limits of 160 square feet of friable ACM on facility components or 260 linear feet of friable ACM on pipes (quantities involved over a one-year period). For renovation operations in which the amount of ACM equals or exceeds the NESHAP limits, notification is required as soon as possible. [Pg.93]

Sea water feed for the stills is pumped from the Halifax River, which at the point of feed intake has a salinity of about 35,000 p.p.m., the same as that of the ocean. Much of the research instrumentation is housed in a centrally located concrete block shelter, which was constructed underground principally to prevent its shading the nearby stills. One of the previously existing buildings on the reservation was renovated to provide an office, a conference room, and equipment storage space. [Pg.169]

Level 1 There are no health objections to TVOC values below 0.3 mg/m3 provided no guide values are exceeded. They are referred to as target values (health precautions range) and can be reached once a sufficient period of time has elapsed following new building construction or renovation work in rooms-or they can, if possible, be undershot. [Pg.202]

Over a period of 6 months following the construction of new buildings or renovation, the higher TVOC values, which were measured under standardized conditions, should have fallen markedly. The time curve for concentration can be documented by means of repeated measurements and a time curve forecast drawn up. [Pg.203]


See other pages where Renovation, building is mentioned: [Pg.123]    [Pg.2150]    [Pg.190]    [Pg.142]    [Pg.300]    [Pg.34]    [Pg.1]    [Pg.154]    [Pg.123]    [Pg.2150]    [Pg.190]    [Pg.142]    [Pg.300]    [Pg.34]    [Pg.1]    [Pg.154]    [Pg.326]    [Pg.201]    [Pg.511]    [Pg.24]    [Pg.250]    [Pg.427]    [Pg.196]    [Pg.670]    [Pg.496]    [Pg.464]    [Pg.1160]    [Pg.69]    [Pg.126]    [Pg.232]    [Pg.98]    [Pg.365]    [Pg.370]    [Pg.88]    [Pg.93]    [Pg.1160]    [Pg.267]    [Pg.326]    [Pg.446]    [Pg.382]    [Pg.203]   


SEARCH



Renovation

© 2024 chempedia.info