Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Relaxation methods nonlinear

Relaxation methods for the study of fast electrode processes are recent developments but their origin, except in the case of faradaic rectification, can be traced to older work. The other relaxation methods are subject to errors related directly or indirectly to the internal resistance of the cell and the double-layer capacity of the test electrode. These errors tend to increase as the reaction becomes more and more reversible. None of these methods is suitable for the accurate determination of rate constants larger than 1.0 cm/s. Such errors are eliminated with faradaic rectification, because this method takes advantage of complete linearity of cell resistance and the slight nonlinearity of double-layer capacity. The potentialities of the faradaic rectification method for measurement of rate constants of the order of 10 cm/s are well recognized, and it is hoped that by suitably developing the technique for measurement at frequencies above 20 MHz, it should be possible to measure rate constants even of the order of 100 cm/s. [Pg.178]

The nonlinear iterative methods described here are based on the linear relaxation methods developed in Sections III. C.l and III.C.2 of Chapter 3. Initially, the correction term was set equal to zero in regions where o(k) was nonphysical. To illustrate this, we may rewrite the point-simultaneous equation [Chapter 3, Eq. (23)] with a relaxation parameter that depends on the estimate d(k) ... [Pg.103]

As a whole, the procedure of measurement and mathematical evaluation is closely analogous to laser diffraction measurements in the Fraunhofer domain 5, but the problems arising from the numerical instability of the linear equation system are even more severe. Thus the Phillips-Twomey-Algorithm (PTA), successfully applied in laser diffraction spectrometry, will perform poorly in the presence of systematic errors, as they may arise from unknown particle shape or particle material. A nonlinear iterative procedure however, the relaxation method, has proven to yield excellent results even under difficult conditions. [Pg.490]

We elose with tliree eonnnents. First, there is preliminary work on retrieving not only the amplitude but also the phase of photon eehoes [49]. This appears to be a promising avenue to aequire eomplete 2-dimensional time and freqiieney infonnation on the dynamies, analogous to methods tliat have been used in NMR. Seeond, we note that there is a growing literature on non-pertnrbative, niimerieal simulation of nonlinear speetroseopies. In these methods, the eonsisteney of the order of interaetion with the field and the appropriate relaxation proeess is aehieved automatieally. [Pg.267]

Relaxation data may be analyzed by two general methods a two-parameter, linear regression and a three-parameter, nonlinear, fitting procedure. " " The first method requires an accurate experimental determination of Mo, which is both difficult and time-consuming. Furthermore, the... [Pg.142]

A method is described for fitting the Cole-Cole phenomenological equation to isochronal mechanical relaxation scans. The basic parameters in the equation are the unrelaxed and relaxed moduli, a width parameter and the central relaxation time. The first three are given linear temperature coefficients and the latter can have WLF or Arrhenius behavior. A set of these parameters is determined for each relaxation in the specimen by means of nonlinear least squares optimization of the fit of the equation to the data. An interactive front-end is present in the fitting routine to aid in initial parameter estimation for the iterative fitting process. The use of the determined parameters in assisting in the interpretation of relaxation processes is discussed. [Pg.89]

The discretized equations of the finite volume method are solved through an iterative process. This can sometimes have difficulty converging, especially when the nonlinear terms play a strong role or when turbulence-related quantities such as k and s are changing rapidly, such as near a solid surface. To assist in convergence a relaxation factor can be introduced ... [Pg.341]

For oo, (co) approaches unity, provided that l — t(co) < 1. In this case, 0 k) is just the object estimated by inverse filtering. For k finite, the inverse-filter estimate is modified by a factor that suppresses frequencies for which t (co) is small. The larger k is, the less is this suppression. For typical transfer functions t(co) that suppress high frequencies, the factor B(co) controls the high-frequency content of o k In the spectrum domain, it is also possible to derive simple expressions for filters y(x) that are fully equivalent to an arbitrary number of relaxation iterations. Blass and Halsey (1981) have done so, but the highly useful nonlinear modifications of these methods cannot be incorporated. [Pg.84]

As described in the section on nonlinear absorption, the transmission of a pulse which is short compared to the various molecular relaxation times is determined by its energy content. A measurement of the energy transmission ratio will then give the peak intensity of the pulse when its pulse shape is known 44>. In fact, the temporal and spatial pulse shape is of relatively little importance. Fig. 11 gives the energy transmission as a function of the peak intensity I [W/cm2] for the saturable dye Kodak 9860 with the pulse halfwidth as a parameter. It is seen that this method is useful in the intensity region between 10 and 1010 MW/cm2 for pulses with halfwidths greater than 5 to 10 psec. Since one can easily manipulate the cross-section and hence the intensity of a laser beam with a telescope, this method is almost universally applicable. [Pg.17]

Petrie and Ito (84) used numerical methods to analyze the dynamic deformation of axisymmetric cylindrical HDPE parisons and estimate final thickness. One of the early and important contributions to parison inflation simulation came from DeLorenzi et al. (85-89), who studied thermoforming and isothermal and nonisothermal parison inflation with both two- and three-dimensional formulation, using FEM with a hyperelastic, solidlike constitutive model. Hyperelastic constitutive models (i.e., models that account for the strains that go beyond the linear elastic into the nonlinear elastic region) were also used, among others, by Charrier (90) and by Marckmann et al. (91), who developed a three-dimensional dynamic FEM procedure using a nonlinear hyperelastic Mooney-Rivlin membrane, and who also used a viscoelastic model (92). However, as was pointed out by Laroche et al. (93), hyperelastic constitutive equations do not allow for time dependence and strain-rate dependence. Thus, their assumption of quasi-static equilibrium during parison inflation, and overpredicts stresses because they cannot account for stress relaxation furthermore, the solutions are prone to numerical instabilities. Hyperelastic models like viscoplastic models do allow for strain hardening, however, which is a very important element of the actual inflation process. [Pg.854]

A further issue arises in the Cl solvation models, because Cl wavefunction is not completely variational (the orbital variational parameter have a fixed value during the Cl coefficient optimization). In contrast with completely variational methods (HF/MFSCF), the Cl approach presents two nonequivalent ways of evaluating the value of a first-order observable, such as the electronic density of the nonlinear term of the effective Hamiltonian (Equation 1.107). The first approach (the so called unrelaxed density method) evaluates the electronic density as an expectation value using the Cl wavefunction coefficients. In contrast, the second approach, the so-called relaxed density method, evaluates the electronic density as a derivative of the free-energy functional [18], As a consequence, there should be two nonequivalent approaches to the calculation of the solvent reaction field induced by the molecular solute. The unrelaxed density approach is by far the simplest to implement and all the Cl solvation models described above have been based on this method. [Pg.89]

A consistent study of the linear and lowest nonlinear (quadratic) susceptibilities of a superparamagnetic system subjected to a constant (bias) field is presented. The particles forming the assembly are assumed to be uniaxial and identical. The method of study is mainly the numerical solution (which may be carried out with any given accuracy) of the Fokker-Planck equation for the orientational distribution function of the particle magnetic moment. Besides that, a simple heuristic expression for the quadratic response based on the effective relaxation... [Pg.533]

Shalagin, A.M. (1977). Determination of relaxation characteristics by a polarization method in nonlinear spectroscopy, Zhumal Eksperimental noi i Teoreticheskoi Fiziki, 73, 99-111. [5ov. Phys.—JETP, 46, 50-56]. [Pg.290]


See other pages where Relaxation methods nonlinear is mentioned: [Pg.177]    [Pg.249]    [Pg.183]    [Pg.435]    [Pg.183]    [Pg.219]    [Pg.318]    [Pg.82]    [Pg.45]    [Pg.1577]    [Pg.2116]    [Pg.136]    [Pg.204]    [Pg.500]    [Pg.374]    [Pg.143]    [Pg.150]    [Pg.418]    [Pg.68]    [Pg.380]    [Pg.113]    [Pg.362]    [Pg.385]    [Pg.15]    [Pg.240]    [Pg.564]    [Pg.72]    [Pg.234]    [Pg.51]    [Pg.137]    [Pg.466]    [Pg.304]    [Pg.351]    [Pg.341]    [Pg.147]    [Pg.125]   
See also in sourсe #XX -- [ Pg.102 , Pg.103 , Pg.104 , Pg.105 , Pg.106 , Pg.107 , Pg.108 , Pg.109 , Pg.110 ]




SEARCH



Nonlinear methods

© 2024 chempedia.info