Real-time concentration

Mid-IR has also been demonstrated for real-time concentration monitoring of a fermentation using a standard transmission cell, and the spectral response was similar, regardless of whether the broth was filtered or not.38 A PLS regression was used to perform quantitation of the substrate, the lactic acid bacterium, and the major metabolites. In another article describing quantitative mid-IR for fermentation studies, a model system was investigated under various fermentation conditions.39 The mid-IR provided insight into the relative concentrations of carbohydrates, nucleic acids, proteins and lipids in the host cells. Mid-IR has also been demonstrated for multi-component quantitation... [Pg.337]

Figure 6. Real time concentration response of sodium sensor... Figure 6. Real time concentration response of sodium sensor...
Moment analysis. A technique for obtaining analytical information on the elution curve described by Equation 25 is to make use of the moment generating property of Laplace transforms (41). It is readily shown that the various moments of the real-time concentration profile are related to the transform solution by the following ... [Pg.94]

Measurement Science Sampling Frequency Analysis Rate Sample Preparation Specificity Wet Chemistry Electro- or Ion Optics Batch Continuous Off-Line Real Time Concentration-Conversion Whole Air Species Classes Species Isotopomers... [Pg.146]

The same holds true for remote sensing applications. Imagine a day when blood concentrations of important analytes are determined not in a batch mode, but rather through the use of a fiber-optic bundle inserted into an artery. Each fiber is equipped with a different chemosensor, such that the real-time concentrations of several dozen analytes are provided on a monitor at the patient s bedside. Devices for real-time monitoring of blood pH, pOj, and PCO2 that are now available use fluorescent chemosensors. Technical issues, some of them daunting, await new blood monitoring devices nevertheless, the payoff seems worth the research investments. [Pg.242]

The adliesion and fiision mechanisms between bilayers have also been studied with the SEA [M, 100]. Kuhl et al [17] found that solutions of short-chained polymers (PEG) could produce a short-range depletion attraction between lipid bilayers, which clearly depends on the polymer concentration (fignre Bl.20.1 It. This depletion attraction was found to mduce a membrane fusion widiin 10 minutes that was observed, in real-time, using PECO fringes. There has been considerable progress in the preparation of fluid membranes to mimic natural conditions in the SEA [ ], which promises even more exciting discoveries in biologically relevant areas. [Pg.1742]

Hydrocarbon vapor migration within the carbon canister is a significant factoi during the real time diurnal test procedure. The phenomenon occurs after the canister has been partially charged with fuel vapors. Initially the hydrocarbons will reside primarily in the activated carbon that is closest to the fuel vapor source. Over time, the hydrocarbons will diffuse to areas in the carbon bed with lower HC concentration. Premature break through caused by vapor migration for twc different canisters is shown in Fig. 17. The canister with the L/D ratio of 5.0 shows substantially lower bleed emissions than the canister with an L/D ratio of 3.0. [Pg.256]

Primarily models chemical releases to the air. Includes a chemical database and map editor and is capable of mapping concentration isopleths. Allows real-time meteorological data input. [Pg.285]

In the measurement of emission gas mass concentration at sources, a gas sample is extracted via an automatic isokinetic particulate-sampling instrument. The monitoring system generates a direct, real-time emission particulate mass... [Pg.1289]

FIGURE 5.4 Microphysiometry responses of HEK 293 cells transfected with human calcitonin receptor, (a) Use of microphysiometry to detect receptor expression. Before transfection with human calcitonin receptor cDNA, HEK cells do not respond to human calcitonin. After transfection, calcitonin produces a metabolic response, thereby indicating successful membrane expression of receptors, (b) Cumulative concentration-response curve to human calcitonin shown in real time. Calcitonin added at the arrows in concentrations of 0.01, 0.1, 1.10, and lOOnM. Dose-response curve for the effects seen in panel B. [Pg.82]

Another major second messenger in cells is calcium ion. Virtually any mammalian cell line can be used to measure transient calcium currents in fluorescence assays when cells are preloaded with an indicator dye that allows monitoring of changes in cytosolic calcium concentration. These responses can be observed in real time, but a characteristic of these responses is that they are transient. This may lead to problems with hemi-equilibria in antagonist studies whereby the maximal responses to agonists may be depressed in the presence of antagonists. These effects are discussed more fully in Chapter 6. [Pg.83]

Each simulation, done in real time at a computer terminal, takes but a moment to complete. It is thus quite practical to vary in turn each of the starting conditions and rate constants for different time ranges. This procedure allows the investigator to assess how important the variation of one parameter is in determining the concentration of each species. (This is a sensitivity analysis.)... [Pg.118]

Obviously, the fast-fill-and-hold method is preferred from the viewpoint of elapsed time. More importantly, the fed-batch method requires an accurate process model that may not be available. The fast-fill-and-hold method can use a process model or it can use a real-time measurement of concentration. [Pg.523]

E.coli recA y.luxCDABE strain were grown for 16-18 hours at 37°C in LB-broth in the presence of 20 pg/ ml of ampicillin. Immediately before the experiment the culture was diluted 1 20 by fresh culture medium and incubated until early log-phase. The grown biomass was mixed with AR solutions in final concentrations of ICfs, ICH n ICfs M, with used for their dilution with distilled water (control) and incubated for 60 minutes. The luminescence intensity of UV-irradiated E.coli recA lux and intact specimens were registered by plate bioluminometer LM OIT (Immimotech, Czech Rep.) in a real time. The number of viable cells was determined from the colony-forming units (CFU) on a surface of a LB-agar after the subsequent incubation within 24 hours at 37 °C. A quantitative estimation of an induction of the SOS-system calculated on formula... [Pg.188]

The general operation of the pilot scale reactor has be previously described by Pareek et. al. [3]. However, modifications were required to allow the injection of the gas and liquid tracers, and their subsequent detection at the outlets. The liquid tracer, 5mL Methyl blue solution (lOgL" ), was injected via a syringe inserted into the liquid feed line. Outlet samples were measured with a Shimadzu 1601 UV-Vis Spectrophotometer at a wavelength of 635nm. A pulse (20mL) of helium gas tracer was introduced using an automated control system, with the outlet concentration monitored in real-time with a thermal conductivity detector. Runs were carried out based on a two-level... [Pg.669]

Solutions of c acetate buffer, pH 5.0, were injected into the flow cell and passed over the PGIP surface at the flow rate of 10 il/min. The interaction was followed in real time at different analyte concentrations. The binding was monitored as a mass change in the vicinity of the sensor surfiice, reflecting the progress of the interaction. [Pg.776]


See other pages where Real-time concentration is mentioned: [Pg.6]    [Pg.76]    [Pg.516]    [Pg.442]    [Pg.156]    [Pg.574]    [Pg.6]    [Pg.338]    [Pg.338]    [Pg.184]    [Pg.253]    [Pg.221]    [Pg.223]    [Pg.159]    [Pg.294]    [Pg.225]    [Pg.6]    [Pg.76]    [Pg.516]    [Pg.442]    [Pg.156]    [Pg.574]    [Pg.6]    [Pg.338]    [Pg.338]    [Pg.184]    [Pg.253]    [Pg.221]    [Pg.223]    [Pg.159]    [Pg.294]    [Pg.225]    [Pg.76]    [Pg.510]    [Pg.330]    [Pg.1116]    [Pg.1117]    [Pg.50]    [Pg.60]    [Pg.117]    [Pg.163]    [Pg.687]    [Pg.53]    [Pg.14]    [Pg.240]    [Pg.287]    [Pg.305]    [Pg.623]   
See also in sourсe #XX -- [ Pg.268 , Pg.269 ]




SEARCH



Concentration time

Real-time

Solution concentration measurement real-time