The shutdown of SMART can be achieved by a function of one of two independent systems. The primary shutdown system is 32 shutdown banks of CEA of which absorbing material is B4C. The control banks are dropped into the reactor core by the gravity force and immediately stops die neutron chain reactions. These control banks have sufficient shutdown margin to bring the reactor fi-om hot full power to hot shutdown, even with a most reactive bank stuck out of the core. For the case of failure of the primary shutdown system, the emergency boron injection system is provided as a backup system and consists of two tanks, 6m ... [Pg.80]

Consider Figure 23.29(a), where, the p.f. of a power circuit is to be improved from cos 0, to cos 02- If kVAri is the reactive component of power at p.f. cos 0, which is to be improved to kVAr2, at p.f. co.s 0i, through the reactive power coinpensation, then the reactive component of power compensated or kVAr rating of the required capacitor banks... [Pg.760]

This is a highly recommended method of capacitor switching for installations that are large and require very fine monitoring and correction of p.f. with the smallest number of banks. The entire reactive requirement is arranged in only a few steps yet a small correction up to the smallest capacitor unit is possible. The relay is sequenced so that through its binary counter the required switching is achieved in small steps, with just four or six sets of capacitor units or banks. The operation of the entire sequence can be illustrated as follows ... [Pg.769]

When the reactive control is not automatic, then during offpeak periods (such as during the night) it is important that some of the banks are dropped manually to avoid an overcompensation and a consequent overvoltage. [Pg.838]

This part considers reactive power control with the use of shunt and series capacitors. The controls may be manual or automatic through electromagnetic or static devices. Protection of capacitors and capacitor banks as well as design, manufacturing and test requirements, installation and maintenance are also covered, the main thrust being on the application of power capacitors. [Pg.990]

In this solvent the reaction is catalyzed by small amounts of trimethyl-amine and especially pyridine (cf. 9). The same effect occurs in the reaction of iV -methylaniline with 2-iV -methylanilino-4,6-dichloro-s-triazine. In benzene solution, the amine hydrochloride is so insoluble that the reaction could be followed by recovery. of the salt. However, this precluded study mider Bitter and Zollinger s conditions of catalysis by strong mineral acids in the sense of Banks (acid-base pre-equilibrium in solution). Instead, a new catalytic effect was revealed when the influence of organic acids was tested. This was assumed to depend on the bifunctional character of these catalysts, which act as both a proton donor and an acceptor in the transition state. In striking agreement with this conclusion, a-pyridone is very reactive and o-nitrophenol is not. Furthermore, since neither y-pyridone nor -nitrophenol are active, the structure of the catalyst must meet the conformational requirements for a cyclic transition state. Probably a concerted process involving structure 10 in the rate-determining step... [Pg.300]

Currently thousands of system combinations have been programmed on the ARRADCOM s CDC 6600 computer with additions and updates made as received. The program is being enlarged to include reactivity with hydraulic fluids, lubricants, metals, etc. Another data bank-maintained is a Hazard Failure program, which is aimed at warning users about potential problems... [Pg.787]

Herd KJ (1994) Fluorine-containing dyes A Reactive dyes. In Organofluorine Chemistry Principles and Commercial Applications (Eds RE Banks, BE Smart, JC Tatlow), pp. 287-314. Plenum Press, London. [Pg.669]

In 1979 he moved to University College, Cardiff, where he was Head of Department (1987-1997), a Deputy Principal (1990-1992) and is currently a Research Professor. He was invited to be World Bank Visiting Professor in China in 1985, a Visiting Professor at Berkeley and is an Honorary Fellow of the University of Wales, Swansea. He was the first Chairman of the Surface Reactivity and Catalysis Group (SURCAT) of the RSC. [Pg.231]

Banks, T.M. (2003). Reactivity, Mutagenicity and DNA Damage of N-acyloxy-N-Alkoxy-amides. Ph.D., University of New England... [Pg.120]

NACs in a laboratory column system containing aquifer material from the banks of a river-groundwater infiltration site (Fig. 14.11). The columns were run under ferrogenic conditions. Note that zero-order kinetics suggests that the reactive sites were always saturated such as encountered in enzyme kinetics at saturation (Box 12.2). In this system, all model compounds as well as other NACs including again TNT, ADNTs, and DANTs (data not shown, see Hofstetter et al., 1999) reacted at virtually the same rate. However, when present in mixtures, the compounds showed competition for the reactive sites. A competition quotient, Qc (competition with the reference compound 4-C1-NB present at about equal concentrations) was determined for all model compounds ... [Pg.589]

Arc furnaces are operated in conjunction with large capacitor banks and harmonic filters to improve the power factor and also to filter the harmonic frequency currents so they do not unduly affect other power users sharing the same power fines. It is not uncommon to see arc furnaces supplied from dedicated utility power fines to minimize their impact on other power users. The presence of large capacitance in an electrical system can result in voltage rise due to the leading reactive power demands of the capacitors, unless they are adequately canceled by the lagging reactive power required by the loads. This is why capacitor banks, whether for power factor correction or harmonic current filtration, are switched on when the furnace is brought on line and switched off when the arc furnace is off line. [Pg.37]

It was observed in Chapter 4 that capacitor banks must be selected and applied based on power system harmonic studies. This is necessary to eliminate conditions that can actually amplify the harmonics and create conditions that can render the situation considerably worse. One means of providing leading reactive power is by the use of synchronous motors. Synchronous motors applied for power factor control are called synchronous condensers. A synchronous motor normally draws lagging currents, but when its field is overexcited, the motor draws leading reactive currents (Figure 6.11). By adjusting the field currents, the synchronous motor can be made... [Pg.151]


See other pages where Reactive banks is mentioned: [Pg.777]    [Pg.803]    [Pg.777]    [Pg.803]    [Pg.2398]    [Pg.760]    [Pg.769]    [Pg.796]    [Pg.803]    [Pg.804]    [Pg.998]    [Pg.220]    [Pg.265]    [Pg.225]    [Pg.225]    [Pg.302]    [Pg.357]    [Pg.428]    [Pg.217]    [Pg.564]    [Pg.89]    [Pg.1256]    [Pg.93]    [Pg.174]    [Pg.260]    [Pg.1256]    [Pg.490]    [Pg.302]    [Pg.112]    [Pg.107]    [Pg.151]    [Pg.152]    [Pg.152]    [Pg.236]    [Pg.346]   