Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Radiofrequency measurements

Accuracy of the radiofrequency measurements of the classic 2S — 2P Lamb shift [15, 16, 23, 24, 25] is limited by the large (about 100 MHz) natural width of the 2P state, and cannot be significantly improved. New perspectives in reducing the experimental error bars of the classic 2S — 2P Lamb shift were opened with the development of the Doppler-free two-photon laser spectroscopy for measurements of the transitions between the energy levels with different principal quantum numbers. Narrow linewidth of such transi-... [Pg.237]

For radiofrequency measurements of the fine structure of hydrogen, on the other hand, the Doppler effect is completely tmimportant, since it is proportional to the frequency which is actually measured. The fine structure intervals are given by frequency differences in optical spectroscopy in radiofrequency spectroscopy they are measured directly. The greater precision of radiofrequency measurements would compel careful investigation of the conditions in a gas discharge if this method were chosen for the excitation of the atoms. In fact, in the radio-frequency experiments which have so far been performed on hydrogen and ionized helium, the method of excitation by electron bombardment has been used. [Pg.7]

The broad agreement between experiment and theory is most satisfactory. The dependence on Z is particularly well verified by the radiofrequency measurement on He+, n = 2. The dependence on n over the wide range from 1 to 4 is verified to within the precision of optical measurements. [Pg.65]

With the envisioned higher resolution, it should be possible to determine a better value of the electron/proton mass ratio from a precise measurement of the isotope shift. And a measurement of the absolute frequency or wavelength should provide a new value of the Rydberg constant with an accuracy up to 1 part in 10, as limited by uncertainties in the fine structure constant and the mean square radius of the proton charge distribution. A comparison with one of the Balmer transitions, or with a transition to or between Rydberg states could provide a value for the IS Lamb shift that exceeds the accuracy of the best radiofrequency measurements of the n=2 Lamb shift. Such experiments can clearly provide very stringent tests of quantum electrodynamic calculations, and when pushed to their limits, they may well lead to some surprising fundamental discovery. [Pg.67]

There are other important properties tliat can be measured from microwave and radiofrequency spectra of complexes. In particular, tire dipole moments and nuclear quadmpole coupling constants of complexes may contain useful infonnation on tire stmcture or potential energy surface. This is most easily seen in tire case of tire dipole moment. The dipole moment of tire complex is a vector, which may have components along all tire principal inertial axes. [Pg.2442]

Measurements of Stark splittings in microwave and radiofrequency spectra allow tliese components to be detennined. The main contribution to tire dipole moment of tire complex arises from tire pennanent dipole moment vectors of tire monomers, which project along tire axes of tire complex according to simple trigonometry (cosines). Thus, measurements of tire dipole moment convey infonnation about tire orientation of tire monomers in tire complex. It is of course necessary to take account of effects due to induced dipole moments and to consider whetlier tire effects of vibrational averaging are important. [Pg.2442]

The technique for measurement which is most easily interpreted is the inversion-recovery method, in which the distribution of the nuclear spins among the energy levels is inverted by means of a suitable 180° radiofrequency pulse A negative signal is observed at first, which becomes increasingly positive with time (and hence also with increasing spin-lattice relaxation) and which... [Pg.63]

In NMR spectroscopy the precise energy differences between such nuclear magnetic states are of interest. To measure these differences, electromagnetic waves in the radiofrequency region (1-600 MHz) are applied, and the frequency at which transitions occur between the states, is measured. At resonance the condition... [Pg.461]

Figure 1 shows the detailed steps of the measurement, from the perspective of a coordinate system rotating with the applied radiofrequency giq = yA)- The sample is in the magnetic field, and is placed inside an inductor of a radiofirequency circuit... [Pg.461]

Figure 2. Partial 100 MHz P.M.R. Spectrum of 3,4,6-tri-O-acetyl-v-glucal (1) measured for a chloroform -d solution (A normal spectrum of the Hi and H2 resonances respectively (B) frequency sweep spin-decoupled spectrum of the Hi and H2 resonances, with a strong decoupling field centred on the Hs resonance (C), as in (B) above, but with an additional weak radiofrequency field centred on the high field transition of the H2 resonance (D), as in (B) above, but with a weak radiofreauency field centred on the low field transition... Figure 2. Partial 100 MHz P.M.R. Spectrum of 3,4,6-tri-O-acetyl-v-glucal (1) measured for a chloroform -d solution (A normal spectrum of the Hi and H2 resonances respectively (B) frequency sweep spin-decoupled spectrum of the Hi and H2 resonances, with a strong decoupling field centred on the Hs resonance (C), as in (B) above, but with an additional weak radiofrequency field centred on the high field transition of the H2 resonance (D), as in (B) above, but with a weak radiofreauency field centred on the low field transition...
Greatly enhanced sensitivity with very short measuring time is the major advantage of PFT (pulse Fourier transform) experiments. In the CW (continuous wave) experiment, the radiofrequency sweep excites nuclei of different Larmor frequencies, one by one. For example, 500 s may be required for excitation over a 1-KHz range, while in a PFT experiment a single pulse can simultaneously excite the nuclei over 1-KHz range in only 250 jits. The PFT experiment therefore requires much less time than the CW NMR experiment, due to the short time required for acquisition of FID signals. Short-lived unstable molecules can only be studied by PFT NMR. [Pg.85]

The basic components of the solid state spectrometer are the same as the solution-phase instrument data system, pulse programmer, observe and decoupler transmitters, magnetic system, and probes. In addition, high-power amplifiers are required for the two transmitters and a pneumatic spinning unit to achieve the necessary spin rates for MAS. Normally, the observe transmitter for 13C work requires broadband amplification of approximately 400 W of power for a 5.87-T, 250-MHz instrument. The amplifier should have triggering capabilities so that only the radiofrequency (rf) pulse is amplified. This will minimize noise contributions to the measured spectrum. So that the Hartmann-Hahn condition may be achieved, the decoupler amplifier must produce an rf signal at one-fourth the power level of the observe channel for carbon work. [Pg.107]

The radiofrequency pulses involved in MRI cause thermal heating of the tissues, and are thus subject to FDA limits on the amount of RF power that is transmitted to a subject during a medical scan. The RF power unit is specified as the specific absorption rate (SAR) and is measured in watts per kilogram of body tissue (W/kg tissue). Powers that exceed this level put the subject at risk of tissue damage incurred as a result of the tissue s inability to remove the heat through blood flow. [Pg.940]


See other pages where Radiofrequency measurements is mentioned: [Pg.328]    [Pg.328]    [Pg.661]    [Pg.309]    [Pg.312]    [Pg.319]    [Pg.328]    [Pg.328]    [Pg.661]    [Pg.309]    [Pg.312]    [Pg.319]    [Pg.553]    [Pg.415]    [Pg.565]    [Pg.553]    [Pg.238]    [Pg.188]    [Pg.5]    [Pg.10]    [Pg.21]    [Pg.290]    [Pg.567]    [Pg.163]    [Pg.257]    [Pg.4]    [Pg.206]    [Pg.255]    [Pg.287]    [Pg.289]    [Pg.418]    [Pg.436]    [Pg.551]    [Pg.629]    [Pg.324]    [Pg.328]    [Pg.158]    [Pg.951]    [Pg.299]    [Pg.69]    [Pg.217]    [Pg.238]    [Pg.111]   


SEARCH



Radiofrequency

Radiofrequency pulses measure

Radiofrequency pulses measure relaxation times

Times radiofrequency pulses measure

© 2024 chempedia.info