Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pumps/pumping flow control

Liquid fuels require their own pumps, flow control, nozzles, and mixing systems. Many gas turbines are available... [Pg.286]

The ease with which the separated products leave the bowl determines the richness of the fat. Fluid whole milk enters the separator under pressure from a positive displacement pump or centrifugal pump with flow control (Fig. 1). The fat (cream) is separated and moves toward the center of the bowl, while the skimmed milk passes to the outer space. There are two spouts or oudets, one for cream and one for skimmed milk. Cream leaves the center of the bowl with the percentage of fat ( 30 40%) controlled by the adjustment of a valve, called a cream or skim milk screw, that controls the flow of the product leaving the field of centrifugal force and thus affects the separation. [Pg.353]

Process-flow control and buffer-gas control have been discussed under Variable Nozzles and Buffer-Gas System respectively. Speed is usually self-controlled by a matching speed-sensitive load such as a compressor or a pump. If the load is an induction or svn-chronous generator feeding into a stable ac system, the system frequency fixes the speed. Otherwise, the speed can be controlled by a conventional governor. [Pg.2524]

Some toll processes lend themselves to test runs in the pre-startup phase. Actual materials for the toll may be used in the test or substitute materials, typically with low hazard potential, are often used to simulate the charging, reaction, and physical changes to be accomplished in the toll. Flow control, temperature control, pressure control, mixing and transferring efficiency can be measured. Mechanical integrity can be verified in regard to pumps, seals, vessels, heat exchangers, and safety devices. [Pg.103]

Thermal power plant auxiliaries such as flow control of primary air fan, ID fan and forced-draught fans, boiler feed pumps circulating water pumps and condensate pumps, coal handling plant (e.g. ball mill, wagon tippler, and stacker reclaimer)... [Pg.145]

At the time of the solvent methanol experiments a metering pump was used. In some experiments the pulsating action of the pump can be disturbing, so a high-pressure syringe-type pump can be used. Since mass flow controllers are available now, the combination of a gas-pressurized feed tank on an electronic scale for liquid level indication and a mass flow controller seems to be a good choice. Both the feed tank and separator can be heated or cooled. In the case of the solvent methanol experiments. [Pg.90]

Our example system has a flow-controlled feed, and the reboiler heat is controlled by cascade from a stripping section tray temperature. Steam is the heating medium, with the condensate pumped to condensate recovery. Bottom product is pumped to storage on column level control overhead pressure is controlled by varying level in the overhead condenser the balancing line assures sufficient receiver pressure at all times overhead product is pumped to storage on receiver level control and reflux is on flow control. [Pg.290]

As the flow rate and quantity of liquor are the most important controllable variables in developing design data, a feed pump suitable for accurate and continuous flow is required. Depending on the size of the pilot column system, the use of peristaltic, diaphragm, piston-type or centrifugal pumps are recommended. The feed pump should be used in combination with a volumetric or gravimetric flow control... [Pg.431]

Figure 12-26. The SIMULAR reaction calorimeter. Features include pumped liquid feed, gas mass flow control, gas evolution measurement, and distillation equipment. (Source Hazard Evaluation Laboratory Ltd.)... Figure 12-26. The SIMULAR reaction calorimeter. Features include pumped liquid feed, gas mass flow control, gas evolution measurement, and distillation equipment. (Source Hazard Evaluation Laboratory Ltd.)...
Total flow vacuum pump Exhaust control with bypass controller valve... [Pg.1291]

FV - Flow Control Valve T - Tank P - Pump PV - Pressure Control Valve RV - Relief Valve V - Valve 1 - 1 inch size P - Pressure T - Temperature L - Level F - Flow I - Indicator C - Controller A - Alarm H - High. L - Low... [Pg.203]

Simo, F, Which Flow Control V alve or Pump , Hydro. Proc., V. 52, No. 7, 1973. [Pg.223]

Primarily for flow controlled requirements, such as solids suspensions, heat transfer, and other high pumping efficiency applications. [Pg.291]

Pumping effectiveness or pumping per power is important for flow controlled processes [29]. [Pg.302]

Oldshue [29] expresses pumping effectiveness as pumping per power and recognizes it as a key function for processes that are flow controlled or need more flow- than head or shear. [Pg.305]

Installations that have sharp turns, shut-off, flow-control valves, or undersized pipe on the suction-side of the pump are prone to chronic performance problems. Such deviations from good engineering practices result in turbulent suction flow and cause hydraulic instability that severely restricts pump performance. [Pg.521]

In most fluid power systems, the motor is required to provide actuating power in either direction. In these applications, the ports are referred to as working ports, alternating as inlet and outlet ports. Either a four-way directional control valve or a variable-displacement pump usually controls the flow to the motor. [Pg.609]

Brine maybe pumped to each cooling device, and the flow controlled by means of shut-off or bypass valves to maintain the correct temperature (see Figure 12.5)... [Pg.151]


See other pages where Pumps/pumping flow control is mentioned: [Pg.110]    [Pg.156]    [Pg.66]    [Pg.234]    [Pg.444]    [Pg.267]    [Pg.94]    [Pg.32]    [Pg.502]    [Pg.26]    [Pg.78]    [Pg.80]    [Pg.749]    [Pg.1687]    [Pg.2267]    [Pg.2531]    [Pg.595]    [Pg.548]    [Pg.73]    [Pg.1291]    [Pg.268]    [Pg.211]    [Pg.302]    [Pg.308]    [Pg.513]    [Pg.607]    [Pg.1064]    [Pg.220]    [Pg.191]   