Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pumped stars

The yellow dragon is manufactured by pressing the composition into a paper tube. When it is not pressed, it smokes quite quickly and this J.S used for stars of the daylight yellow chrysanthemum(Fig.79) In this case the composition can be used v/ithout consolidation or granulation. The yellov willow composition is formed into pumped stars and is coated with gypsum as it is with the white willow described above. ... [Pg.229]

This tidrieCt covers probably iho moA comprehensive division of the art of fireworks making. Besides the end less variety of colors, efeCts etc. we have the cut ftar, box Aar, pumped Star, candle Star etc. Nearly all Stars are made by dampening the composition with water (if composition contains dextrine) or alcohol (if it contains shellac) and pressing the caked mass into little cubes, cylinders etc, by the various devices to be described. [Pg.230]

Component As defined in NHB 5300.41(10-2), A combination of parts, devices, and structures, usually self-contained, which performs a distinctive function in the operation of the overall equipment. A black box (e.g., transmitter, encoder, cryogenic pump, star tracker) (NSTS 22254). [Pg.358]

When a gas is compressed, it heats up. When it expands, it cools. Anyone who uses a bicycle pump knows this. However, it is no longer true for electron or neutron gases at very high densities. This deviation from the ideal gas laws has a catastrophic effect on stars. Moreover, the behaviour of a photon gas with regard to volume changes differs from that of a typical gas made up of atoms,... [Pg.129]

Cylindrical stars are commonly pumped using hand-operated pumps that are forced into the tray of composition. The pump comprises a line of brass or copper tubes, each fitted with a spring-loaded plunger to eject the compressed composition in the form of a star that is of the same diameter as the tube. [Pg.104]

A red star might be based on potassium perchlorate, strontium carbonate and charcoal together with various binders and solvents to facilitate the pumping of solid stars. The composition for a green star... [Pg.104]

Volume of the pump chamber stars to decrease (without compression). Pressure increase to 1000 mbar only by admitting cold gas. [Pg.37]

The paper elements can be folded into various forms which appear as pleated, star-shaped or V-shaped patterns. These elements are wrapped or coiled around a central porous metal core. Fuels generally flow from the outside shell of the filter inward through the filter media and up through the central core of the filter to the fuel pump feed line. [Pg.238]

A typical polymerization reactor is shown in Figure 2. The reactor contains a side-ampoule used to isolate a portion of the "living" linear precursor before star-linking by the addition of DVB. The reactor was purified by flaming with a hand torch while continuously pumping until a pressure of 10 was reached. The... [Pg.558]

It is absolutely necessary to provide proper grounding of all components in the setup. The microscope, the manipulators and the bath have to be shielded by a Faraday cage. The amplifiers, the PC system, oscilloscopes and roller pump are located outside the cage. All components of the setup have to be connected to a star point. This is often represented by... [Pg.117]

The phylum Echinodermata comprises about 7000 living species [177]. Echinoderm means spiny-skinned and these organisms are characterised by the tube feet, which they use to move about. These have suction discs on the ends, which operate by an internal bulb pumping water in and out of the foot, causing expansion and contraction. The phylum is sub-divided into five classes the asteroids (sea stars), the holothurians (sea cucumbers), the crinoids (sea lilies), the echinoids (sea urchins) and the ophiuroids (brittle stars) [178]. As stated in the introduction to this review, sulfated sterols and saponins, which comprise the majority of echinoderm metabolites containing sulfur, are not included here. [Pg.716]

Roman candles are repeating guns which shoot projectiles of colored fire and send out showers of glowing sparks between the shots. To the pyrotechnists of the seventeenth century they were known as star pumps or pumps with stars. ... [Pg.79]

For the preparation of a small number of stars, a star pump is a convenient instrument. This consists of a brass tube with a plunger which slides within it. The plunger has a handle and, on its side, a peg which works within a slot in the side of the tube— in such manner that it may be fixed in position to leave at the open end of the tube a space equal to the size of the star which it is desired to make. This space is then tightly packed with the damp mixture the plunger is turned so that the peg may move through the longitudinal slot, and the handle is pushed to eject the star. [Pg.81]

Weingart31 reports compositions for cut, pumped, or candle stars which contain chlorate but no sulfur or sulfides, as follows ... [Pg.85]

The materials are mixed intimately while dampened with water, and the mixture is pumped into stars about % inch in diameter and % inch long. The stars are dried promptly. They function only when falling through the air. If lighted on the ground they merely smolder, but when fired from rockets or shells are most effective. [Pg.87]

Figure 4. Response surface for (a) confined and (b) un con fined assumptions for the example depicted in Figure 3. The optimal solution is indicated by the star. The minimum saturated thickness b at the wells is contoured in (b). Negative pumping rates imply extraction. Figure 4. Response surface for (a) confined and (b) un con fined assumptions for the example depicted in Figure 3. The optimal solution is indicated by the star. The minimum saturated thickness b at the wells is contoured in (b). Negative pumping rates imply extraction.
Figure 6 Schematic of a complete multiplexed and integrated instrumental design for PCR analysis with eight channels. Different functional capillaries were connected by a T-assembly and a cross-assembly. Stars represent the freeze/thaw valves V1 and V2. A syringe pump and a six-way selection valve were used to load and distribute liquids for various purposes. A CCD camera was used to collect fluorescence from the eight capillaries simultaneously. The temperature control unit at the cross-assembly was used to denature DNA prior to injection. (Reprinted from Ref. 34 with permission.)... Figure 6 Schematic of a complete multiplexed and integrated instrumental design for PCR analysis with eight channels. Different functional capillaries were connected by a T-assembly and a cross-assembly. Stars represent the freeze/thaw valves V1 and V2. A syringe pump and a six-way selection valve were used to load and distribute liquids for various purposes. A CCD camera was used to collect fluorescence from the eight capillaries simultaneously. The temperature control unit at the cross-assembly was used to denature DNA prior to injection. (Reprinted from Ref. 34 with permission.)...
To model experimentally the formation and properties of solid particles that form in the outflows of stars under realistic conditions appropriate to a circumstellar outflow, we would need a system large enough that the walls of the chamber are unimportant and the chamber itself needs to be pumped down to pressures that are several orders of magnitude less than the partial pressure of the least abundant reactant. In a typical stellar outflow SiO is present at 10-6 the abundance of hydrogen, while hydrogen is present at 1010 particles per cm3. In practical terms, this means that the experimental system must be capable of achieving a vacuum better than 10-15 atm and operate at about 10-9 atm or less. These conditions are barely achievable in terrestrial laboratories. However, for wall effects to be unimportant, the chamber radius must be several times the mean free path of the gas at 10-9 atm the mean free path is 100m. [Pg.131]

Hub up the mixture thoroughly In a mortar with just enough boiled oil to make it cohere, and pump it into Homan candle stars the oil will preserve the steel from rusting. For Roman candles or Italian streamers they will be ready at any time for rockets and shells they may bo matched and enveloped, like figure 32. a day or two previously. They form beautiful stars. Or they may be charged in cases, and primed with chlorate meal powder. Or they may be damped with lao solution. [Pg.16]

In the STAR process (steam active reforming) feed is heated and mixed with steam before passing to the reactor. This avoids the use of pumping to lower the partial pressure of the reactants. The outline of the process is shown in Figure 10.5. ... [Pg.191]


See other pages where Pumped stars is mentioned: [Pg.98]    [Pg.362]    [Pg.182]    [Pg.231]    [Pg.233]    [Pg.264]    [Pg.182]    [Pg.98]    [Pg.362]    [Pg.182]    [Pg.231]    [Pg.233]    [Pg.264]    [Pg.182]    [Pg.74]    [Pg.406]    [Pg.418]    [Pg.50]    [Pg.226]    [Pg.481]    [Pg.4]    [Pg.193]    [Pg.315]    [Pg.188]    [Pg.137]    [Pg.88]    [Pg.27]    [Pg.790]    [Pg.606]    [Pg.9]    [Pg.19]    [Pg.167]   
See also in sourсe #XX -- [ Pg.99 ]

See also in sourсe #XX -- [ Pg.99 ]




SEARCH



Pumps with stars

Star pump

Star pump

© 2024 chempedia.info