Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pulsed illumination

The mathematical treatment of pulsing illumination has been described [Briers et al., 1926], After a number of cycles, the radical concentration oscillates uniformly with a constant radical concentration [M-] j at the end of each light period of duration t and a constant radical concentration [M-]2 at the end of each dark period of duration t = rt. The two radical concentrations are related by... [Pg.266]

Now we consider the situation in which the control pulse illuminates a vibronic system at a delay t after the initial pump pulse. Assuming the pulse characteristics are identical between the pump and control pulses, the total WP after the irradiation of the control pulse is given as... [Pg.287]

Peterson and Bridenbaugh examined the transient emissions under pulsed illumination, and all data were taken at room temperature. The 5D4 state of terbium has a mean life of about 581 /xsec in the compound... [Pg.277]

Figure 2 Diagram of a generalized 2D-PIV setup showing all major components flow channel with the particle seeded fluid flow, laser sheet pulses illuminating one plane in the fluid, a CCD camera imaging the particles in the laser-illuminated sheet in the area of interest, a computer with PIV software installed, a timing circuit communicating with the camera and computer and generating pulses to control the double-pulsed laser. The PIV software setups and controls the major components, and analyses the images to derive a vector representation of flow field (see Plate 4 in Color Plate Section at the end of this book). Figure 2 Diagram of a generalized 2D-PIV setup showing all major components flow channel with the particle seeded fluid flow, laser sheet pulses illuminating one plane in the fluid, a CCD camera imaging the particles in the laser-illuminated sheet in the area of interest, a computer with PIV software installed, a timing circuit communicating with the camera and computer and generating pulses to control the double-pulsed laser. The PIV software setups and controls the major components, and analyses the images to derive a vector representation of flow field (see Plate 4 in Color Plate Section at the end of this book).
The above-discussed photocurrent measurements were performed under the steady-state illumination of electrodes. In the pulse illumination mode, the photo-... [Pg.260]

The photocurrent decay, under pulsed illumination, is strongly accelerated upon anodic or O-plasma oxidation of diamond surface. This effect is believed to be due to removal of the above-mentioned subsurface hydrogen [169]. [Pg.261]

The photocurrent responses of nanocrystalline electrodes to stepped or pulsed illumination exhibit features on rather slow timescales. This is illustrated, for example, by Fig. 8.26, which is a set of photocurrent transients reported by Solbrand et al. [78] for band-band excitation at 308 nm of nanocrystalline Ti02 films of differing thicknesses permeated by 0.7 mol dm-3 LiC104 in ethanol. The 30 ns excimer laser pulse was incident from the solution side, and since the penetration depth of the light was much smaller than the film thickness, electron-hole pairs were effectively... [Pg.268]

The protein concentration used in the near-IR measurements was about 7 mM in heme. The protein solution was filtered through either a 0.45 pm or a 0.22 pm membrane filter prior to being anaerobically transferred into a gas-tight 1-mm-path-length sample cell. The sample cell was rotated sufficiently quickly to ensure that each photolysis pulse illuminated a fresh volume within the protein sample. The temperature of the sample was about 28°C, which was elevated somewhat from ambient temperature due to heating by the motorized mount. [Pg.207]

Regardless of the photo catalyst employed, repetitive laser pulse illumination increased 0hcho in the oxygenated suspensions by a factor of ca. 1.5 in comparison with CW illumination, although in both modes of photolysis the time-averaged photon absorption rate was approximately the same [82], Previous studies on intermittent illumination in Ti02 photocatalysis offer no satisfying explanation for this observation [86-91]. [Pg.384]

Cornu et al. investigated the quantum yield, 4>f, of photocatalytic formate oxidation in oxygenated acidic Ti02 suspension under continuous and periodic pulse illumination [91]. For very short illumination times in periodic pulse photolysis, Cornu et al. demonstrated that 4>f was identical to the value obtained under continuous illumination at the same time-averaged photon absorption rate. This is in sharp contrast to the results of Wang et al. for photocatalytic methanol oxidation [82],... [Pg.384]

Delayed fluorescence is seldom significant, even when T2 is thermally accessible from E. The behavior in Cr(urea)g and Cr(D20)6 is the exception rather than the rule. Under either steady or pulsed illumination... [Pg.231]

Fig. 38. Block diagram of the lamp circuit for pulsed illumination studies. From ref. 133b. Fig. 38. Block diagram of the lamp circuit for pulsed illumination studies. From ref. 133b.
A very similar technique is that of pulsed illumination which corresponds very closely to flash photolysis except that the intensities of the flashes are 10" times those in the latter technique. The method has been used to determine the rate coefficients for reactions (14) and (15). [Pg.51]

In the case of the line scan, the number of pulses illuminated on the linear region to be imaged (20 jam) was about one-sixth of the total laser pulses, because of an angle-range selection of the scan mirror in which its angular speed is approximately constant. [Pg.321]

The second point worth noting is that the response of nanocrystalline Ti02 electrodes to large amplitude excursions of light intensity such as a light step is nonlinear. Furthermore, the shape of the photocurrent response is intensity dependent. The photocurrent transients for square pulse illumination of dye sensitised Ti02 films reported by Cao et al. [80] and shown in Fig. 35 illustrate this very well. [Pg.136]

Figure 1.30 Photovoltammogram of a Cu2ZnSnS4 layer measured in 0.2 M Eu(N03)3 under pulsed illumination from a white LED. The cathodic photoresponse shows that the sample is... Figure 1.30 Photovoltammogram of a Cu2ZnSnS4 layer measured in 0.2 M Eu(N03)3 under pulsed illumination from a white LED. The cathodic photoresponse shows that the sample is...
Fig. 1.35 Optothermal spectroscopy of solids and of molecules adsorbed at surfaces (a) propagation of thermal wave induced by a pulsed laser (b) deformation of a surface detected by the deflection of a HeNe laser beam (c) time profile of surface temperature change following pulsed illumination [90]... Fig. 1.35 Optothermal spectroscopy of solids and of molecules adsorbed at surfaces (a) propagation of thermal wave induced by a pulsed laser (b) deformation of a surface detected by the deflection of a HeNe laser beam (c) time profile of surface temperature change following pulsed illumination [90]...
Particularly the temperature measurement with encapsulated TLCs shows extensive deviation in the reflected wave length. To minimize this, the illumination technique should be enhanced to receive a uniform illuminated FOV. Furthermore strong illumination is needed for applications with high lateral and temporal resolution. Another problem is the heat introduced by the illumination especially when continuous volume illumination is used. A pulsed illumination decreases this effect. [Pg.1653]

Finally, there are also bioelectric currents flowing in the retina. They are detectable using corneal electrodes, and the monitored biopotential is known as an electroretinogram (ERG). It changes in amplitude and waveshape with pulsed illumination. A strobe light, for example, will produce a transient ERG biopotential of nearly 1 mV. [Pg.439]

These inhibitors limit Chi accumulation and, as a consequence, an array of Chl-binding proteins. Recent studies, using chlorina mutants and/or pulsed illumination, suggested biosynthesis models of PS2 (8-10) and PSl (8) in which reaction center cores are first assembled, then a stabilization of LHC antennas. Gabaculine and AHA, by limiting Chi, may have a greater impact on the later biosynthetic steps. [Pg.2628]

Figure 1. CO2 transport was examined by pulsing illuminated cells with CO2 contained in small aliquots of acidified water saturated with 5% v/v CO2 at 0 C. Cells were suspended in buffer, pH 8, with 25 mM NaCl containing (a) 0, (b) 60, (c) 90, (d) 180 pM Na2S or (f)... Figure 1. CO2 transport was examined by pulsing illuminated cells with CO2 contained in small aliquots of acidified water saturated with 5% v/v CO2 at 0 C. Cells were suspended in buffer, pH 8, with 25 mM NaCl containing (a) 0, (b) 60, (c) 90, (d) 180 pM Na2S or (f)...
Figure 14.13 Response of the short-circuit photocurrent of P3HT F8TBT solar cells to a square pulse illumination of varying intensity. Turn-on of the source is at 0 is and turn-off at 100 is. (a) The experimental photocurrent transients (b) the photocurrent transients simulated using a time-dependent drift diffusion model... Figure 14.13 Response of the short-circuit photocurrent of P3HT F8TBT solar cells to a square pulse illumination of varying intensity. Turn-on of the source is at 0 is and turn-off at 100 is. (a) The experimental photocurrent transients (b) the photocurrent transients simulated using a time-dependent drift diffusion model...

See other pages where Pulsed illumination is mentioned: [Pg.464]    [Pg.50]    [Pg.266]    [Pg.384]    [Pg.30]    [Pg.228]    [Pg.286]    [Pg.101]    [Pg.74]    [Pg.275]    [Pg.278]    [Pg.136]    [Pg.333]    [Pg.71]    [Pg.6]    [Pg.840]    [Pg.2879]    [Pg.71]    [Pg.6381]   
See also in sourсe #XX -- [ Pg.50 , Pg.51 ]




SEARCH



Fiber illumination and pulse shape

Illuminated

Illumination

© 2024 chempedia.info