The use of a convective macroporous polymer as an alternative support material instead of silica for the preparation of protein-based CSPs has successfully been demonstrated by Hofstetter et al. [221]. Enantioseparation was performed using a polymeric flow-through-type chromatographic support (POROS-EP, 20 pm polymer particles with epoxy functionalities) and covalently bound BSA as chiral SO. Using flow rates of up to 10 ml/min, rapid enantiomer separation of acidic compounds, including a variety of amino acid derivatives and drugs, could be achieved within a few minutes at medium efficiencies, typical for protein chiral stationary phases (Fig. 9.13). [Pg.384]

Chiral Chromatography. Chiral chromatography is used for the analysis of enantiomers, most useful for separations of pharmaceuticals and biochemical compounds (see Biopolymers, analytical techniques). There are several types of chiral stationary phases those that use attractive interactions, metal ligands, inclusion complexes, and protein complexes. The separation of optical isomers has important ramifications, especially in biochemistry and pharmaceutical chemistry, where one form of a compound may be bioactive and the other inactive, inhibitory, or toxic. [Pg.110]

Separation of enantiomers by physical or chemical methods requires the use of a chiral material, reagent, or catalyst. Both natural materials, such as polysaccharides and proteins, and solids that have been synthetically modified to incorporate chiral structures have been developed for use in separation of enantiomers by HPLC. The use of a chiral stationary phase makes the interactions between the two enantiomers with the adsorbent nonidentical and thus establishes a different rate of elution through the column. The interactions typically include hydrogen bonding, dipolar interactions, and n-n interactions. These attractive interactions may be disturbed by steric repulsions, and frequently the basis of enantioselectivity is a better steric fit for one of the two enantiomers. ... [Pg.89]

S. G. Allenmark, Separation of enantiomers by protein-based chiral phases in A practical approach to chiral separations by liquid chromatogra.phy, G. Subramanian, VCH, Weinheim (1994) Chapter 7. [Pg.19]

Proteins. A chiral stationary phase with immobilized a -acid glycoprotein on silica beads was introduced by Hermansson in 1983 [18, 19]. Several other proteins such as chicken egg albumin (ovalbumin), human serum albumin, and cellohy-drolase were also used later for the preparation of commercial CSPs. Their selectivity is believed to occur as a result of excess of dispersive forces acting on the more retained enantiomer [17]. These separation media often exhibit only modest loading capacity. [Pg.58]

There is a wide variety of commercially available chiral stationary phases and mobile phase additives.32 34 Preparative scale separations have been performed on the gram scale.32 Many stationary phases are based on chiral polymers such as cellulose or methacrylate, proteins such as human serum albumin or acid glycoprotein, Pirkle-type phases (often based on amino acids), or cyclodextrins. A typical application of a Pirkle phase column was the use of a N-(3,5-dinitrobenzyl)-a-amino phosphonate to synthesize several functionalized chiral stationary phases to separate enantiomers of... [Pg.12]

Membranes offer a format for interaction of an analyte with a stationary phase alternative to the familiar column. For certain kinds of separations, particularly preparative separations involving strong adsorption, the membrane format is extremely useful. A 5 x 4 mm hollow-fiber membrane layered with the protein bovine serum albumin was used for the chiral separation of the amino acid tryptophan, with a separation factor of up to 6.6.62 Diethey-laminoethyl-derivatized membrane disks were used for high-speed ion exchange separations of oligonucleotides.63 Sulfonated membranes were used for peptide separations, and reversed-phase separations of peptides, steroids, and aromatic hydrocarbons were accomplished on C18-derivatized membranes. [Pg.65]

Because plasma and urine are both aqueous matrixes, reverse-phase or polar organic mode enantiomeric separations are usually preferred as these approaches usually requires less elaborate sample preparation. Protein-, cyclodextrin-, and macrocyclic glycopeptide-based chiral stationary phases are the most commonly employed CSPs in the reverse phase mode. Also reverse phase and polar organic mode are more compatible mobile phases for mass spectrometers using electrospray ionization. Normal phase enantiomeric separations require more sample preparation (usually with at least one evaporation-to-dryness step). Therefore, normal phase CSPs are only used when a satisfactory enantiomeric separation cannot be obtained in reverse phase or polar organic mode. [Pg.328]

As yet, the number of applications is limited but is likely to grow as instrumentation, mostly based on existing CE systems, and columns are improved and the theory of CEC develops. Current examples include mixtures of polyaromatic hydrocarbons, peptides, proteins, DNA fragments, pharmaceuticals and dyes. Chiral separations are possible using chiral stationary phases or by the addition of cyclodextrins to the buffer (p. 179). In theory, the very high efficiencies attainable in CEC mean high peak capacities and therefore the possibility of separating complex mixtures of hundreds of... [Pg.648]

Ligand binding, in proteins, 20 829-830 Ligand-exchange phases, for chiral separations, 6 82-83 Ligands... [Pg.519]

Chiral separations result from the formation of transient diastereomeric complexes between stationary phases, analytes, and mobile phases. Therefore, a column is the heart of chiral chromatography as in other forms of chromatography. Most chiral stationary phases designed for normal phase HPLC are also suitable for packed column SFC with the exception of protein-based chiral stationary phases. It was estimated that over 200 chiral stationary phases are commercially available [72]. Typical chiral stationary phases used in SFC include Pirkle-type, polysaccharide-based, inclusion-type, and cross-linked polymer-based phases. [Pg.221]

Manipulation of mobile phase and temperature parameters can have some unusual effects on chiral separations. Variation of temperature and mobile phase composition has been reported to reverse the elution order on protein phases and polysaccharide phases (Persson and Andersson, 2001). [Pg.24]

Analysis using a CMPA is usually resolved on a nonchiral column. A transient diastereomeric complex is formed between the enantiomer and the chiral component in the mobile phase, similar to the complexes formed with chiral stationary phases. A review by Liu and Liu (2002) cites several papers where addition of CPMAs has been used in analyzing amphetamine-related compounds. Some CPMAs include amino acid enantiomers, metal ions, proteins, and cyclodextrins. Advantages of this method of analysis include the use of less expensive columns and more flexibility in the optimization of chiral separation (Misl anova and Hutta, 2003). [Pg.25]

Armstrong et al. ° first introduced chiral stationary phases based on macrocyclic antibiotics. Vancomycin, ristocetin A, teicoplanin, avoparcin, rifamycin B and thiostrepton are used as chiral selectors. They posses a broad enantiorecognition range, similar to protein based CSPs. However, CSPs based on macrocyclic antibiotics show higher stability and capacities.Underivatized amino acids, N-derivatized amino-acids, acidic compounds, neutrals, amides, esters and amines can be separated.The first four of the above-mentioned chiral selectors appear to have the largest enantiorecognition range.The selectors can also be derivatized to obtain different enantioselectivities. [Pg.472]

The use of protein immobilised to the surface of a silica gel or to another support has been a very successful approach for the chiral separation of various pharmaceuticals. The AGP stationary phase has been shown to have the broadest enantiorecognition abilities while the BSA stationary phase is especially useful for aromatic compounds. " Table 9 shows some examples of separations that were obtained on the protein-type of CSPs. [Pg.476]

Proteins, amino acids bonded through peptide linkages to form macromolecular biopolymers, used as chiral stationary phases for hplc include bovine and human serum albumin, OL-acid glycoprotein, ovomucoid, avidin, and cellobiohydrolase. The bovine serum albumin column is marketed under the name Resolvosil and can be obtained from Phenomenex. The human serum albumin column can be obtained from Alltech Associates, Advanced Separation Technologies, Inc., and J. T. Baker. The a1-acid glycoprotein and cellobiohydrolase can be obtained from Advanced Separation Technologies, Inc. or J. T. Baker, Inc. [Pg.66]

Chiral separations on protein-based phases may also provide useful information on drug interactions. For instance, the effect of the individual enantiomers of warfarin on the enantioselectivity of human serum albumin toward benzodiazepinones has been studied using a human serum albumin... [Pg.66]

The molecular imprinting strategy can be applied for the recognition of different kinds of templates from small organic molecules to biomacromolecules as proteins. Some examples of separations investigated with MIP monoliths in CEC and LC are shown in Table 2. The influence of the imprinted monolithic phase preparation procedure and of the separation conditions on the selectivity and chromatographic efficiency have been widely studied [154, 157, 161, 166, 167, 192]. The performance of imprinted monoliths as chromatographic stationary phase has also been compared to that of the traditional bulk polymer packed column [149, 160]. It was shown that the monolithic phases yielded faster analyses and improved chiral separations. [Pg.66]

In view of the importance of chiral resolution and the efficiency of liquid chromatographic methods, attempts are made to explain the art of chiral resolution by means of liquid chromatography. This book consists of an introduction followed by Chapters 2 to 8, which discuss resolution chiral stationary phases based on polysaccharides, cyclodextrins, macrocyclic glyco-peptide antibiotics, Pirkle types, proteins, ligand exchangers, and crown ethers. The applications of other miscellaneous types of CSP are covered in Chapter 9. However, the use of chiral mobile phase additives in the separation of enantiomers is discussed in Chapter 10. [Pg.31]

Allenmark S, Protein based phases, in Chiral Separations by HPLC Applications to Pharmaceutical Compounds, Krstulovic AM (Ed.), Ellis Horwood, New York (1989). [Pg.257]


See other pages where Protein chiral separation phases is mentioned: [Pg.61]    [Pg.63]    [Pg.242]    [Pg.262]    [Pg.4]    [Pg.59]    [Pg.433]    [Pg.19]    [Pg.73]    [Pg.322]    [Pg.238]    [Pg.263]    [Pg.263]    [Pg.511]    [Pg.518]    [Pg.361]    [Pg.361]    [Pg.363]    [Pg.363]    [Pg.1267]    [Pg.61]    [Pg.63]    [Pg.66]    [Pg.255]   
See also in sourсe #XX -- [ Pg.116 ]




SEARCH



Chiral phases

Chiral phases protein

Chiral separations

Chiral separations chirality

Chiralic separation

Chirality/Chiral phases

Phases chirality

Separator Protein

© 2024 chempedia.info