Problem with beam sensitivity

Overall a customer needs to know under what circumstances it is best to use either the electron-beam techniques of EDS and WDS or the X-ray technique of XRF for an analysis problem. If both are equally available, the choice usually resides in whether high spatial resolution is needed, as would be obtained only with electron-beam techniques. If liquids are to be analyzed, the only viable choice is XRF. If one s choice is to use electron-beam methods, the further decision between EDS and WDS is usually one of operator preference. That is, to commence study on a totally new sample most electron-beam operators will run an EDS spectrum first. If there are no serious peak overlap problems, then EDS may be sufficient. If there is peak overlap or if maximum sensitivity is desired, then WDS is usually preferred. Factored into all of this must be the beam sensitivity of the sample, since for WDS analysis the beam current required is lO-lOOx greater than for EDS. This is of special concern in the analysis of polymer materials. [Pg.133]

Surface analysis by non-resonant (NR-) laser-SNMS [3.102-3.106] has been used to improve ionization efficiency while retaining the advantages of probing the neutral component. In NR-laser-SNMS, an intense laser beam is used to ionize, non-selec-tively, all atoms and molecules within the volume intersected by the laser beam (Eig. 3.40b). With sufficient laser power density it is possible to saturate the ionization process. Eor NR-laser-SNMS adequate power densities are typically achieved in a small volume only at the focus of the laser beam. This limits sensitivity and leads to problems with quantification, because of the differences between the effective ionization volumes of different elements. The non-resonant post-ionization technique provides rapid, multi-element, and molecular survey measurements with significantly improved ionization efficiency over SIMS, although it still suffers from isoba-ric interferences. [Pg.132]

Flow limitations restrict application of the DFI interface for pSFC-MS coupling. pSFC-DFI-MS with electron-capture negative ionisation (ECNI) has been reported [421], The flow-rate of eluent associated with pSFC (either analytical scale - 4.6 mm i.d. - or microbore scale 1-2 mm, i.d.) renders this technique more compatible with other LC-MS interfaces, notably TSP and PB. There are few reports on workable pSFC-TSP-MS couplings that have solved real analytical problems. Two interfaces have been used for pSFC-EI-MS the moving-belt (MB) [422] and particle-beam (PB) interfaces [408]. pSFC-MB-MS suffers from mechanical complexity of the interface decomposition of thermally labile analytes problems with quantitative transfer of nonvolatile analytes and poor sensitivity (low ng range). The PB interface is mechanically simpler but requires complex optimisation and poor mass transfer to the ion source results in a limited sensitivity. Table 7.39 lists the main characteristics of pSFC-PB-MS. Jedrzejewski... [Pg.482]

For further enhancement of electron beam sensitivity, the chlorinated Novolak resin was studied using poly (2-methyl-1-pentene sulfone) as a dissolution inhibitor. The chlorinated Novolak resin mixed well with the polysulfone, and there was no phase separation observed when the films were spin-coated. With 13 wt% of the polysulfone, the chlorinated Novolak resist cast from a cellosolve acetate solution yielded fully developed images with R/Ra = 9.2 after exposure to 2 / 2. It gave fully developed images with R/R0 = 3.2 at a dose of 1 / 2, as shown in Figure 3. There are some problems with this resist system some cracking of the developed resist images... [Pg.345]

Beam instability. The use of EXAFS on heterogeneous samples, especially with a microfocused beam, tends to exacerbate certain problems that are well known from other systems. One simple example of such a problem is the sensitivity to beam motion, which results from putting a small beam on an equally small particle. The beam tends to move on the sample during data acquisition, for a variety of reasons. These motions can cause artifacts in the data. For example, during the course of a synchrotron fill, the source point may move, and the decreasing power incident on the optics may also cause position shifts. Vibrations either of the sample or the optics result in increased noise and an increased effective spot size. If the position drifts on a time scale comparable to the length of time required to scan over an EXAFS oscillation, one could get artifacts, which are indistinguishable from EXAFS, except that they do not repeat from scan to scan. If... [Pg.386]


See other pages where Problem with beam sensitivity is mentioned: [Pg.105]    [Pg.640]    [Pg.1800]    [Pg.14]    [Pg.23]    [Pg.138]    [Pg.19]    [Pg.79]    [Pg.88]    [Pg.311]    [Pg.216]    [Pg.262]    [Pg.313]    [Pg.639]    [Pg.41]    [Pg.71]    [Pg.225]    [Pg.19]    [Pg.99]    [Pg.379]    [Pg.286]    [Pg.1800]    [Pg.769]    [Pg.425]    [Pg.229]    [Pg.61]    [Pg.628]    [Pg.773]    [Pg.1209]    [Pg.338]    [Pg.358]    [Pg.13]    [Pg.60]    [Pg.13]    [Pg.26]    [Pg.38]    [Pg.54]    [Pg.485]    [Pg.9]    [Pg.98]    [Pg.428]    [Pg.493]    [Pg.273]    [Pg.278]    [Pg.61]   