Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Probes emission yield

The emission yield from the horseradish peroxidase (HRP)-catalyzed luminol oxidations can be kicreased as much as a thousandfold upon addition of substituted phenols, eg, -iodophenol, -phenylphenol, or 6-hydroxybenzothiazole (119). Enhanced chemiluminescence, as this phenomenon is termed, has been the basis for several very sensitive immunometric assays that surpass the sensitivity of radioassay (120) techniques and has also been developed for detection of nucleic acid probes ia dot-slot. Southern, and Northern blot formats (121). [Pg.268]

The total electron emission yield is the sum of two contributions, one due to the secondary electrons excited by the primary electrons (SEl highly localised at the probe impact zone), the other due to the secondary electrons excited by the backscattered electrons on their return path to the surface (SE2 distributed more diffusely around a point of impact in the case of a light target, cf. Fig. 7.5). The number of secondary electrons created by a backscattered electron is typically two to four times higher than the number created by an incident electron. [Pg.133]

Measurement of the influence of different micellar environments on proton transfer from excited states of 3-hydroxyflavone allows estimates to be made of micelle concentrations from measurement of the tautomer emission yield. Proton transfer reactions of benzimidazole excited singlet states have also been studied in ionic micelles. Magnetic fields are found to affect the behaviour of radicals generated by the photodissociation of benzil in micellar media. The starburst dendrites which are formed by anionic macromolecules in interaction with both anionic and cationic surfactants have been examined by pyrene fluorescence. Benzo[k]fluoranthrene fluorescence has served as a probe of the effects of metal salts on bile salt aggregation. The incorporation and distribution of benzoquinone into liposomes containing amphilic Zn(II) porphyrin has been followed by its effect on the quenching of the excited state °. A comparison of the photochromism of spirobenzpyran derivatives in unilamellar surfactant vesicles and solvent cast surfactant films has also been reported. ... [Pg.25]

With the exception of the scanning probe microscopies, most surface analysis teclmiques involve scattering of one type or another, as illustrated in figure A1.7.11. A particle is incident onto a surface, and its interaction with the surface either causes a change to the particles energy and/or trajectory, or the interaction induces the emission of a secondary particle(s). The particles that interact with the surface can be electrons, ions, photons or even heat. An analysis of the mass, energy and/or trajectory of the emitted particles, or the dependence of the emitted particle yield on a property of the incident particles, is used to infer infomiation about the surface. Although these probes are indirect, they do provide reliable infomiation about the surface composition and structure. [Pg.304]

Fluorometry and Phosphorimetry. Modem spectrofluorometers can record both fluorescence and excitation spectra. Excitation is furnished by a broad-band xenon arc lamp foUowed by a grating monochromator. The selected excitation frequency, is focused on the sample the emission is coUected at usuaUy 90° from the probe beam and passed through a second monochromator to a photomultiplier detector. Scan control of both monochromators yields either the fluorescence spectmm, ie, emission intensity as a function of wavelength X for a fixed X, or the excitation spectmm, ie, emission intensity at a fixed X as a function of X. Fluorescence and phosphorescence can be distinguished from the temporal decay of the emission. [Pg.319]

Between 1923 and 1927, the concepts of quantum efficiency (number of photons emitted divided by number of photons absorbed by a sample) and quantum yield (fraction of excited molecules that emit) had been defined and values determined for many compounds by Vavilov (34). The quantum yield indicates the extent that other energy loss mechanisms compete with emission in an excited molecule. Although the quantum yield is influenced by the molecular environment of the emitter, for a given environment it depends on the nature of the emitting compound and is independent of concentration and excitation wavelength, at least at low concentrations (35). Tlius, it serves as another measurable parameter that can be used to identify the compounds in a sample and also, because of its sensitivity to the surroundings of the luminophore, to probe the environment of the emitter. [Pg.8]

The significant enhancement in emission quantum yields and lifetimes suggests that 3 can be used as a noncovalent probe in immunochemical assay and biophysical studies. This dye is quite soluble in aqueous buffer and interacts with... [Pg.79]

Dialkylanthracene-containing squaraine dyes 17 show intense absorption and emission in the NIR region (720-810 nm) [74]. They are compatible with aqueous environments and show substantial enhancement of quantum yields and fluorescence lifetimes in hydrophobic and micellar media, suggesting that these dyes can be potentially useful as fluorescent probes in biological applications, e.g., for imaging of hydrophobic domains such as cell membranes. [Pg.80]

Molecular rotors are useful as reporters of their microenvironment, because their fluorescence emission allows to probe TICT formation and solvent interaction. Measurements are possible through steady-state spectroscopy and time-resolved spectroscopy. Three primary effects were identified in Sect. 2, namely, the solvent-dependent reorientation rate, the solvent-dependent quantum yield (which directly links to the reorientation rate), and the solvatochromic shift. Most commonly, molecular rotors exhibit a change in quantum yield as a consequence of nonradia-tive relaxation. Therefore, the fluorophore s quantum yield needs to be determined as accurately as possible. In steady-state spectroscopy, emission intensity can be calibrated with quantum yield standards. Alternatively, relative changes in emission intensity can be used, because the ratio of two intensities is identical to the ratio of the corresponding quantum yields if the fluid optical properties remain constant. For molecular rotors with nonradiative relaxation, the calibrated measurement of the quantum yield allows to approximately compute the rotational relaxation rate kor from the measured quantum yield [Pg.284]


See other pages where Probes emission yield is mentioned: [Pg.55]    [Pg.131]    [Pg.317]    [Pg.76]    [Pg.319]    [Pg.631]    [Pg.1408]    [Pg.7]    [Pg.35]    [Pg.297]    [Pg.228]    [Pg.1228]    [Pg.773]    [Pg.739]    [Pg.333]    [Pg.429]    [Pg.377]    [Pg.51]    [Pg.106]    [Pg.437]    [Pg.265]    [Pg.10]    [Pg.11]    [Pg.28]    [Pg.267]    [Pg.282]    [Pg.184]    [Pg.123]    [Pg.47]    [Pg.66]    [Pg.78]    [Pg.80]    [Pg.91]    [Pg.150]    [Pg.162]    [Pg.215]    [Pg.227]    [Pg.290]    [Pg.301]   
See also in sourсe #XX -- [ Pg.822 ]




SEARCH



Emission yield, luminescent probes

© 2024 chempedia.info