Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Potentiometric acid-base titration

Potentiometric titration is actually a form of the multiple known subtraction method. The main advantage of titration procedures, similar to multiple addition techniques in general, is the improved precision, especially at high determinand concentrations. ISEs are suitable for end-point indication in all combination titrations (acid-base, precipitation, complexometric), provided that either the titrand or the titrant is sensed by an ISE. If both the titrant and the titrand are electro-inactive, an electrometric indicator must be added (for example Fe ion can be titrated with EDTA using the fluoride ISE when a small amount of fluoride is added to the sample solution [126]). [Pg.109]

Potentiometric titration and assumed 1 1 metal/fulvate mole ratio in the complex. "Potentiometric and acid-base conductimetric titrations and assumed 1 1 metal/fulvate mole ratio in the complex. [Pg.427]

The most obvious sensor for an acid-base titration is a pH electrode.For example, Table 9.5 lists values for the pH and volume of titrant obtained during the titration of a weak acid with NaOH. The resulting titration curve, which is called a potentiometric titration curve, is shown in Figure 9.13a. The simplest method for finding the end point is to visually locate the inflection point of the titration curve. This is also the least accurate method, particularly if the titration curve s slope at the equivalence point is small. [Pg.290]

Although not commonly used, thermometric titrations have one distinct advantage over methods based on the direct or indirect monitoring of plT. As discussed earlier, visual indicators and potentiometric titration curves are limited by the magnitude of the relevant equilibrium constants. For example, the titration of boric acid, ITaBOa, for which is 5.8 X 10 °, yields a poorly defined equivalence point (Figure 9.15a). The enthalpy of neutralization for boric acid with NaOlT, however, is only 23% less than that for a strong acid (-42.7 kj/mol... [Pg.294]

Partanen, J. I. Karki, M. H. Determination of the Thermodynamic Dissociation Constant of a Weak Acid by Potentiometric Acid-Base Titration, /. Chem. Educ. 1994,... [Pg.359]

Potentiometric titration curves are used to determine the molecular weight and fQ or for weak acid or weak base analytes. The analysis is accomplished using a nonlinear least squares fit to the potentiometric curve. The appropriate master equation can be provided, or its derivation can be left as a challenge. [Pg.359]

The titration of a mixture ofp-nitrophenol (pfQ = 7.0) and m-nitrophenol pK = 8.3) can be followed spectrophotometrically. Neither acid absorbs at a wavelength of 545 nm, but their respective conjugate bases do absorb at this wavelength. The m-nitrophenolate ion has a greater absorbance than an equimolar solution of the p-nitrophenolate ion. Sketch the spectrophotometric titration curve for a 50.00-mL mixture consisting of 0.0500 M p-nitrophenol and 0.0500 M m-nitrophenol with 0.100 M NaOH, and compare the curve with the expected potentiometric titration curves. [Pg.361]

Potcntiomctric Titrations In Chapter 9 we noted that one method for determining the equivalence point of an acid-base titration is to follow the change in pH with a pH electrode. The potentiometric determination of equivalence points is feasible for acid-base, complexation, redox, and precipitation titrations, as well as for titrations in aqueous and nonaqueous solvents. Acid-base, complexation, and precipitation potentiometric titrations are usually monitored with an ion-selective electrode that is selective for the analyte, although an electrode that is selective for the titrant or a reaction product also can be used. A redox electrode, such as a Pt wire, and a reference electrode are used for potentiometric redox titrations. More details about potentiometric titrations are found in Chapter 9. [Pg.494]

This experiment describes the use of coated graphite electrodes for the potentiometric monitoring of precipitation, acid-base, complexation, and redox titrations. [Pg.534]

The method of choice for determining carboxyl groups in lignin is based on potentiometric titration in the presence of an internal standard, /)-hydroxybenzoic acid, using tetra- -butylammonium hydroxide as a titrant (42). The carboxyl contents of different lignins are shown in Table 6. In general, the carboxyl content of lignin increases upon oxidation. [Pg.141]

There is also evidence for stable 3,4-adducts from the X-ray analysis of 2-amino-4-ethoxy-3,4-dihydropteridinium bromide, the nucleophilic addition product of 2-aminopteridine hydrobromide and ethanol (69JCS(B)489). The pH values obtained by potentiometric titration of (16) with acid and back-titration with alkali produces a hysteresis loop, indicating an equilibrium between various molecular species such as the anhydrous neutral form and the predominantly hydrated cation. Table 1 illustrates more aspects of this anomaly. 2-Aminop-teridine, paradoxically, is a stronger base than any of its methyl derivatives each dimethyl derivative is a weaker base than either of its parent monomethyl derivatives. Thus the base strengths decrease in the order in which they are expected to increase, with only the 2-amino-4,6,7-trimethylpteridine out of order, being more basic than the 4,7-dimethyl derivative. [Pg.267]

The holistic thermodynamic approach based on material (charge, concentration and electron) balances is a firm and valuable tool for a choice of the best a priori conditions of chemical analyses performed in electrolytic systems. Such an approach has been already presented in a series of papers issued in recent years, see [1-4] and references cited therein. In this communication, the approach will be exemplified with electrolytic systems, with special emphasis put on the complex systems where all particular types (acid-base, redox, complexation and precipitation) of chemical equilibria occur in parallel and/or sequentially. All attainable physicochemical knowledge can be involved in calculations and none simplifying assumptions are needed. All analytical prescriptions can be followed. The approach enables all possible (from thermodynamic viewpoint) reactions to be included and all effects resulting from activation barrier(s) and incomplete set of equilibrium data presumed can be tested. The problems involved are presented on some examples of analytical systems considered lately, concerning potentiometric titrations in complex titrand + titrant systems. All calculations were done with use of iterative computer programs MATLAB and DELPHI. [Pg.28]

Usually the acid-base properties of poly electrolyte are studied by potentiometric titrations. However it is well known, that understanding of polyelectrolyte properties in solution is based on the knowledge of the thermodynamic properties. Up to now, there is only a small number of microcalorimetry titrations of polyelectrolyte solutions published. Therefore we carried out potentiometric and microcalorimetric titrations of hydrochloric form of the linear and branched polyamines at 25°C and 65°C, to study the influence of the stmcture on the acid-base properties. [Pg.148]

The first comprehensive investigation of the TaF5 - HF - H2O system was performed by Buslaev and Nikolaev [292]. Based on the analysis of solubility isotherms, and on conductometric and potentiometric titrations, the authors concluded that in this solution, tantalum forms oxyfluorotantalic acid, H2TaOF5, similar to the formation of H NbOFs in solutions containing NbF5. [Pg.130]

In acid-base titrations the end point is generally detected by a pH-sensitive indicator. In the EDTA titration a metal ion-sensitive indicator (abbreviated, to metal indicator or metal-ion indicator) is often employed to detect changes of pM. Such indicators (which contain types of chelate groupings and generally possess resonance systems typical of dyestuffs) form complexes with specific metal ions, which differ in colour from the free indicator and produce a sudden colour change at the equivalence point. The end point of the titration can also be evaluated by other methods including potentiometric, amperometric, and spectrophotometric techniques. [Pg.311]

The hydrogen ions thus set free can be titrated with a standard solution of sodium hydroxide using an acid-base indicator or a potentiometric end point alternatively, an iodate-iodide mixture is added as well as the EDTA solution and the liberated iodine is titrated with a standard thiosulphate solution. [Pg.312]

The indicator electrode employed in a potentiometric titration will, of course, be dependent upon the type of reaction which is under investigation. Thus, for an acid-base titration, the indicator electrode is usually a glass electrode (Section 15.6) for a precipitation titration (halide with silver nitrate, or silver with chloride) a silver electrode will be used, and for a redox titration [e.g. iron(II) with dichromate] a plain platinum wire is used as the redox electrode. [Pg.554]

As indicated in Section 2.4 the strength of an acid (and of a base) is dependent upon the solvent in which it has been dissolved, and in Sections 10.19-10.21 it has been shown how this modification of strength can be used to carry out titrations in non-aqueous solvents which are impossible to perform in aqueous solution. Potentiometric methods can be used to determine the end point of such non-aqueous titrations, which are mainly of the acid-base type and offer very valuable methods for the determination of many organic compounds. [Pg.589]

Titrations can be carried out in cases in which the solubility relations are such that potentiometric or visual indicator methods are unsatisfactory for example, when the reaction product is markedly soluble (precipitation titration) or appreciably hydrolysed (acid-base titration). This is because the readings near the equivalence point have no special significance in amperometric titrations. Readings are recorded in regions where there is excess of titrant, or of reagent, at which points the solubility or hydrolysis is suppressed by the Mass Action effect the point of intersection of these lines gives the equivalence point. [Pg.626]

Glomme, A., Marz, J., Dressman, J. B. Comparison of a miniaturized shake-flask solubility method with automated potentiometric acid/base titrations and calculated solubilities. /. Pharm. Set. 2005, 94, 1-15. [Pg.82]

In fact, any type of titration can be carried out potentiometrically provided that an indicator electrode is applied whose potential changes markedly at the equivalence point. As the potential is a selective property of both reactants (titrand and titrant), notwithstanding an appreciable influence by the titration medium [aqueous or non-aqueous, with or without an ISA (ionic strength adjuster) or pH buffer, etc.] on that property, potentiometric titration is far more important than conductometric titration. Moreover, the potentiometric method has greater applicability because it is used not only for acid-base, precipitation, complex-formation and displacement titrations, but also for redox titrations. [Pg.99]

In the practice of potentiometric titration there are two aspects to be dealt with first the shape of the titration curve, i.e., its qualitative aspect, and second the titration end-point, i.e., its quantitative aspect. In relation to these aspects, an answer should also be given to the questions of analogy and/or mutual differences between the potentiometric curves of the acid-base, precipitation, complex-formation and redox reactions during titration. Excellent guidance is given by the Nernst equation, while the acid-base titration may serve as a basic model. Further, for convenience we start from the following fairly approximate assumptions (1) as titrations usually take place in dilute (0.1 M) solutions we use ion concentrations in the Nernst equation, etc., instead of ion activities and (2) during titration the volume of the reaction solution is considered to remain constant. [Pg.99]

Here we shall confine ourselves to the solvents benzene and 1,2-dichloroethane (class 8). Considering benzene, many investigators have demonstrated since the 1930s the feasibility of titrations in this solvent using both potentiometric and spectrophotometric methods, paying much attention to acid-base indicator reactions under the influence of primary, secondary and tertiary amines. Association of carboxylic acids in benzene was studied at a later stage, mainly on the basis of colligative properties, IR spectroscopy and solvent extraction. ... [Pg.285]

Conductometric titrations. Van Meurs and Dahmen25-30,31 showed that these titrations are theoretically of great value in understanding the ionics in non-aqueous solutions (see pp. 250-251) in practice they are of limited application compared with the more selective potentiometric titrations, as a consequence of the low mobilities and the mutually less different equivalent conductivities of the ions in the media concerned. The latter statement is illustrated by Table 4.7108, giving the equivalent conductivities at infinite dilution at 25° C of the H ion and of the other ions (see also Table 2.2 for aqueous solutions). However, in practice conductometric titrations can still be useful, e.g., (i) when a Lewis acid-base titration does not foresee a well defined potential jump at an indicator electrode, or (ii) when precipitations on the indicator electrode hamper its potentiometric functioning. [Pg.301]


See other pages where Potentiometric acid-base titration is mentioned: [Pg.272]    [Pg.876]    [Pg.272]    [Pg.272]    [Pg.358]    [Pg.534]    [Pg.276]    [Pg.134]    [Pg.458]    [Pg.59]    [Pg.54]    [Pg.52]    [Pg.283]    [Pg.523]    [Pg.863]    [Pg.117]    [Pg.506]    [Pg.117]    [Pg.506]    [Pg.100]    [Pg.101]    [Pg.281]    [Pg.282]    [Pg.283]    [Pg.311]    [Pg.340]   
See also in sourсe #XX -- [ Pg.42 ]




SEARCH



Acid-base titrations

Acidity, titration

Acids acid-base titrations

Acids titrations

Bases acid-base titrations

Bases titrations

Potentiometric

Potentiometric titration, acid-base complexation

Potentiometric titration, acid-base oxidation-reduction

Potentiometric titration, acid-base precipitation

Potentiometric titrations

Titratable acid

Titratable acidity

© 2024 chempedia.info