Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Positive control item

Control items are used to control the proper performance of the test system [8 ]. Monitoring and recording performance against negative and positive control items may constitute sufficient proof for the responsiveness of a given test system. Non-response of the test system to the negative control and response to the positive control, within the acceptance criteria, show that the test system is reactive and behaves as expected. [Pg.559]

The positive control item is one that has an impact on the in vitro test system. It is often used to assess aspects such as the characteristics of the test system and if the in vitro methods gives reliable results for this positive control over time in accordance with historical data. Moreover, a positive control, that meets the predefined acceptance criteria, assures that when a test item has no effect on the in vitro method that the negative result is not caused by an error during the testing phase. Therefore, the results from the control test items are of outmost importance to show that a valid run has been performed when test data for each unknown test item are submitted to regulatory authorities. [Pg.560]

Positive control Separate part of the test system treated with an item the response to which is known for the test system the positive control provides evidence that the test system is responsive under the actual conditions of the assay [8],... [Pg.558]

Fig. 1 Example of plate layout. PC positive control, Rl reference item, /VC negative control, UCuntreated control, VC vehicle control, 77 test item... Fig. 1 Example of plate layout. PC positive control, Rl reference item, /VC negative control, UCuntreated control, VC vehicle control, 77 test item...
For positive, negative, and vehicle control items (in those cases where the negative control is different from the solvent control), it may or may not be necessary to determine concentration and... [Pg.559]

Acceptance criteria for reference items, positive, negative and vehicle control items (e.g., purity, known response, cytotoxicity) should be developed and detailed in the SOP. [Pg.560]

According to these standard norms, a compostable plastic demonstrates a satisfactory rate of biodegradation when achieving 90% of the organic carbon in the whole item or for each organic constituent, which is present in the material at a concentration of more than 1 wt% (by diy mass), and is converted to carbon dioxide by the end of the test period when compared to a positive control. [Pg.339]

The method of QT interval measurement is also of great importance (Salvi et al. 2010). ICH E14 recognizes that there are several different methodologies for the measurement of ECG intervals which differ in what to measure in terms of items and characteristics including conventions for lead selection, waveform presentations, definition of T-wave offset, and handling of U-waves. It is not presaiptive about the method chosen but phasizes the need to use a consistent approach. In this context, the use of a positive control such as moxifloxacin, a drug whose effects on ECG waveforms are very well known, is an internal validation of the QT interval measurement methodology and the accuracy of the ECG readers. [Pg.145]

The contractor reported that changes to SHB-7 as well as employee training programs, eliminated all areas of noncompliance. A review by DOE of Section 104.02 of SHB-7 indicated that WSRC is in compliance with the requirements of this section of the Order. However, there appears to be weaknesses in this program involving positive control of access to RCAs. (Refer to comments under "Entry Control Program," for more discussion.) This will remain an open item until the discrepancy is resolved. [Pg.91]

The instrumentation details must be specific in the same way as the other pieces of equipment. The accuracy, range, and type of the various sensors must be specified. The position of the sensors, sampling ports, and control devices must be indicated on the PIDs. The type of controller must be specified as, for example, on-off, proportional, proportional integral, and derivative, etc. As usual, standard items should be selected whenever possible. [Pg.360]

The system is based on an XP Zymate laboratory robot controlled with a 10 slot System V controller using software version XP VI.S2. The system incorporates commerdaUy available hardware, as well as custom hardware. A schematic diagram of the system is shown in Fig. 6.11. The robotic arm and the peripheral laboratory stations that the robotic arm interacts with to perform the appHcation are positioned in a circular configuration. The GC/MS is located adjacent to the bench top, such that the injection valve is close to the sipper station. Peripheral items of hardware with which the robotic arm does not directly interact with are outside the working envelope. [Pg.189]

During this step, a preliminary analysis of the parts is performed. Typically, the focus is a visual examination of the items. The investigators should avoid disturbing data until necessary, conducting their visual examination without alterations. Take pictures of the items and mark positions in the field if immediate removal is necessary. Remove the parts in a controlled, careful, and methodical manner. Evaluate the importance of coatings/residues/deposits/impurities. Samples of the chemicals, soil, deposits, and coatings may be taken at this point. [Pg.163]

In a recent report, the mean CY-BOCS score at initial assessment (23 6.5) did not differ between child and adolescent OCD subjects. It should be noted that although the CY-BOCS is an anchored ordinal scale, it is not linear and lacks sensitivity to change when symptoms are severely impairing. For example, time occupied is scored as 4 when more than 8 hours/day are spent in either obsessions or compulsions, while 4 hours/day would rate a score of 3—i.e., a 50% decrease in time lowers this item score by one point (out of 5 ordinal scores). It is for this reason that a decrease in CY-BOCS score of more than 25% is considered clinically significant improvement and a number of controlled studies have used a 25% reduction to define a positive response. The CY-BOCS remains the gold standard for both baseline evaluation as well as for monitoring effects of treatment. [Pg.514]


See other pages where Positive control item is mentioned: [Pg.815]    [Pg.816]    [Pg.820]    [Pg.821]    [Pg.103]    [Pg.815]    [Pg.816]    [Pg.820]    [Pg.821]    [Pg.103]    [Pg.328]    [Pg.312]    [Pg.150]    [Pg.328]    [Pg.318]    [Pg.328]    [Pg.341]    [Pg.157]    [Pg.554]    [Pg.560]    [Pg.566]    [Pg.312]    [Pg.820]    [Pg.283]    [Pg.301]    [Pg.79]    [Pg.221]    [Pg.330]    [Pg.193]    [Pg.357]    [Pg.365]    [Pg.129]    [Pg.174]    [Pg.97]    [Pg.177]    [Pg.33]    [Pg.343]    [Pg.121]    [Pg.37]    [Pg.433]    [Pg.547]    [Pg.155]   
See also in sourсe #XX -- [ Pg.103 , Pg.236 , Pg.276 , Pg.377 ]




SEARCH



Position control

Position controller

Position item

© 2024 chempedia.info