Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polystyrenes dielectric studies

A DIELECTRIC STUDY OF THE LOW TEMPERATURE MOLECULAR MOTIONS IN POLYSTYRENE AND THE POLY /0-. M-. OR P-CHLOROSTYRENES/. PH. D. THESIS. [Pg.175]

We wanted to be able to correct measurements of dielectric loss (conductance) and dielectric constant of polymerizing styrene solutions for whatever contribution arose from the dead polystyrene present in the solutions. What better way to make polystyrene that was free of all catalyst fragments and polar groups than to irradiate pure, dry styrene Using the same exhaustive drying technique that we were developing for our a-methylstyrene studies, we prepared a batch of pure, dry styrene. This was then to be irradiated under such conditions that approximately 15% conversion to polymer would occur. [Pg.182]

The dielectric relaxation of bulk mixtures of poly(2jS-di-methylphenylene oxide) and atactic polystyrene has been measured as a function of sample composition, frequency, and temperature. The results are compared with earlier dynamic mechanical and (differential scanning) calorimetric studies of the same samples. It is concluded that the polymers are miscible but probably not at a segmental level. A detailed analysis suggests that the particular samples investigated may be considered in terms of a continuous phase-dispersed phase concept, in which the former is a PS-rich and the latter a PPO-rich material, except for the sample containing 75% PPO-25% PS in which the converse is postulated. [Pg.42]

Polystyrene and polybutadiene homopolymers as well as random and block copolymers of these mers have been studied via dielectric relaxation spectroscopy and tensile stress-strain measurements. The results suggest that some block copolymer systems studied have styrene rich surfaces which appear to partially crosslink upon initial exposure to ozone even though surface oxygen concentrations are not significantly affected. After continued exposure these samples appear to then undergo chain scission. Complex plane analysis implies that after degradation... [Pg.269]

Similar solution behavior was reported(9-11) for sulfonate ionomers. Rochas eit al. (9) observed a polyelectrolyte effect for acrylonitrile-methallylsulfonate copolymers in DMF. Lundberg and Phillips(10) studied the effect of solvents, with dielectric constants ranging from c 2.2 to e 46.7, on the dilute solution viscosity of the sulfonic acid and Na-salt derivatives of sul-fonated polystyrene (SPS). For highly polar solvents such as DMF and dlmethylsulfoxide (DMSO, e 46.7) they observed a polyelectrolyte effect, but for relatively non-polar solvents such as THF and dioxane (c = 2.2) no polyelectrolyte effect was observed. Like Schade and Gartner, these authors concluded that polar solvents favor ionization of the metal sulfonate group while non-polar solvents favor ion-pair interactions. [Pg.36]

Few studies have been conducted heretofore on sulfonated ionomers in solvents which can be considered relatively polar, as defined by a high dielectric constant. A recent study (13) on acrylonitrile-methallyl sulfonate copolymers in dimethyl-formamide is a notable exception. S-PS is readily soluble in a wide variety of solvents, some of them exhibiting rather high values of dielectric constant, such as dimethylformamide (DMF) or dimethylsulfoxide (DMSO). The reduced viscosity-concentration behavior of sulfonated polystyrene is markedly different in polar solvents from that in nonpolar-solvent systems. Typically there is a marked upsweep in reduced viscosity at low polymer concentrations and clearly a manifestation of classic polyelectrolyte behavior. ( 7)... [Pg.204]

Our experimental results suggest that the switching mechanism is not due to the formation of conductive filaments between the two metal electrodes, which was observed in a polymer film by others [31,32]. It is unlikely that filament formation is the reason for the electronic transitions in our device, since the electrical behavior of our device is strongly dependent on the structure and concentration of the gold nanoparticles. In addition, ac impedance studies, from 20 to 10 Hz (Figure 8.8), indicate that the electronic transitions in our device are different from the dielectric breakdown found in polymer films. We observed dielectric breakdown in a device with a polystyrene film sandwiched between two A1... [Pg.1366]


See other pages where Polystyrenes dielectric studies is mentioned: [Pg.34]    [Pg.220]    [Pg.226]    [Pg.152]    [Pg.557]    [Pg.574]    [Pg.561]    [Pg.836]    [Pg.260]    [Pg.109]    [Pg.307]    [Pg.72]    [Pg.146]    [Pg.44]    [Pg.125]    [Pg.4]    [Pg.33]    [Pg.131]    [Pg.260]    [Pg.222]    [Pg.170]    [Pg.279]    [Pg.599]    [Pg.261]    [Pg.261]    [Pg.179]    [Pg.97]    [Pg.242]    [Pg.123]    [Pg.260]    [Pg.534]    [Pg.294]    [Pg.42]    [Pg.109]    [Pg.303]    [Pg.174]    [Pg.185]    [Pg.206]    [Pg.115]    [Pg.288]    [Pg.330]   
See also in sourсe #XX -- [ Pg.561 ]




SEARCH



Dielectric studies

© 2024 chempedia.info