Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Points-of-entry control

Providing an alternative water supply, instead of treatment of contaminated well water, can be an alternative method of point-of-entry control. The cost of alternative water supply varies widely depending on site locations.100-102... [Pg.643]

The primary contractor at Site A had identified clean zones, buffer zones, and related site control procedures in its written plan however, onsite implementation differed from those specified in the plan. For example, the exclusion zones identified in the plan at the upper pad of the wastewater treatment plant, the dredge area, and the solid waste storage area were marked with signs requiring PPE, but were not labeled with red banners as called for in the plan. In addition, the exclusion zones did not have controlled access through one point of entry as described in the plan, nor were the buffer zones established and demarcated with yellow banners. [Pg.200]

The results of Fig. 19.8 for a swirl number of 1.35 show that the attenuation increased to 10 dB with the velocity of the axial jet up to 42 m/s, and further increase to 47 m/s caused the amplitude to fall from around 6 kPa to less than 1.5 kPa and the attenuation to decrease from 10 dB to almost zero. Similar results were observed with the swirl number of 0.6 the attenuation improved with axial jet velocity up to 60 m/s, after which the amplitude and attenuation decreased. The decline in the amplitude of oscillation and its attenuation by active control was due to the interaction between the axial jet with a large velocity and the central recirculation zone, which caused the flame to move further downstream of the swirler and heat release to occur further from the pressure antinode. The consequent increase in the distance between the point of entry of the oscillated fuel and the active burning zone reduced the effectiveness of the oscillated input due to increased fluid dynamic damping and development of a large difference in phase between different parts of the oscillated flow, especially with swirl surrounding the oscillated axial jet. [Pg.307]

Closing the Loop The simplest representation of the closed feedback loop is shown in Fig. 8-23. The load is shown entering the process at the same point as the manipulated variable because that is the most common point of entry, and because, lacking better information, the elements in the path of the manipulated variable are the best estimates of those in the load path. The load rarely impacts directly on the controlled variable without passing through the dominant lag in the process. Where the load is unmeasured, its current value can be observed as the controller output required to keep the controlled variable Y at set point Ysp. [Pg.13]

Is controlled mainly at the point of entry into the mucosal cells of 16 mg Fe ingested daily, only 1-2 mg enter the intestinal mucosal cell. [Pg.193]

Our group has invested heavily in Fischer Porter brand 4 mm needle valves. These provide fine control when they are opened, and are thus preferable for those sections of the system where control is needed, for example, for solvent removal and at the points of entry to the cryogenic trap and Toepler section. In recent years less expensive, but equally effective teflon needle valves have become available. [Pg.97]

A control valve-pump system proposed by Connell Chemical Ens lncerins. September 28, 1987, p. 123) consists of a centrifugal pump, several heat exchangers, a furnace, an orifice, and a control valve. Liquid is pumped through this circuit and up into a column that operates at 20 psig. Because the line running up the column is full of liquid, there is a hydraulic pressure differential between the base of the column and the point of entry into the column of 15 psi. [Pg.114]

POC (Point of Consumption) Positions in the supply chain that are controlled by 3C rules. The POC signals to suppliers what amount to provide to replace what has been consumed. A POC can be a warehouse location, finished goods stock at a factory, staging point in front of a critical operation, or at the point of entry of material into the plant. [Pg.423]

Perhaps the most likely point of cytokinin control of the cell cycle is in G2 or the entry into mitosis from G2. Transfer of cultured soybean cells to cytokinin-free medium leads to cessation of division but not to DNA synthesis, so the amount of DNA per cell approximately doubles (Short et al. 1974). This would not be expected if the cells became blocked at some point preceding S (i.e., at Gi). [Pg.36]

Unlike the radium bomb, cobalt teletherapy units did not visibly affect the skin at the point of entry into the body. Since a presiding oncologist could not use the reddening of the skin to judge the extent of the treatment, the expertise of a physicist was considered essential. In Canada, the Atomic Energy Control Board would not license a cobalt-60 unit for any medical centre that did not employ a physicist. [Pg.234]


See other pages where Points-of-entry control is mentioned: [Pg.589]    [Pg.642]    [Pg.642]    [Pg.589]    [Pg.642]    [Pg.642]    [Pg.725]    [Pg.419]    [Pg.299]    [Pg.606]    [Pg.99]    [Pg.240]    [Pg.252]    [Pg.43]    [Pg.517]    [Pg.419]    [Pg.517]    [Pg.548]    [Pg.517]    [Pg.517]    [Pg.443]    [Pg.234]    [Pg.306]    [Pg.320]    [Pg.286]    [Pg.494]    [Pg.231]    [Pg.98]    [Pg.34]    [Pg.35]    [Pg.115]    [Pg.193]    [Pg.284]    [Pg.271]    [Pg.6]   


SEARCH



Entry point

Point of entry

© 2024 chempedia.info