Plasma coupling parameter

In most plasmas of interest Fe(i) 1, which means they are ideal. In a dusty plasma (Fridman Ketmedy, 2004) with a dust particle density n, charge Z e, and temperature 7d, the non-ideality parameter (which is also called the Coulomb coupling parameter) is... [Pg.141]

Horlick, G.,Tan, S. H.,Vaughn, M. A., and Rose, C. A. (1985).The effect of plasma operating parameters on analyte signals in inductively coupled plasma-mass spectrometry. Spec-trochim. Acta 40B, 1555-1572. [Pg.161]

Various data sources (44) on plasma parameters can be used to calculate conditions for plasma excitation and resulting properties for microwave coupling. Interactions ia a d-c magnetic field are more compHcated and offer a rich array of means for microwave power transfer (45). The Hterature offers many data sources for dielectric or magnetic permittivities or permeabiHty of materials (30,31,46). Because these properties vary considerably with frequency and temperature, available experimental data are iasufficient to satisfy all proposed appHcations. In these cases, available theories can be appHed or the dielectric parameters can be determined experimentally (47). [Pg.340]

Coupling with its intravenous pharmacokinetic parameters, the extended CAT model was used to predict the observed plasma concentration-time profiles of cefatrizine at doses of 250, 500, and 1000 mg. The human experimental data from Pfeffer et al. [82] were used for comparison. The predicted peak plasma concentrations and peak times were 4.3, 7.9, and 9.3 qg/mL at 1.6, 1.8, and 2.0 hr, in agreement with the experimental mean peak plasma concentrations of... [Pg.415]

On the basis of the preceding discussion, it should be obvious that ultratrace elemental analysis can be performed without any major problems by atomic spectroscopy. A major disadvantage with elemental analysis is that it does not provide information on element speciation. Speciation has major significance since it can define whether the element can become bioavailable. For example, complexed iron will be metabolized more readily than unbound iron and the measure of total iron in the sample will not discriminate between the available and nonavailable forms. There are many other similar examples and analytical procedures that must be developed which will enable elemental speciation to be performed. Liquid chromatographic procedures (either ion-exchange, ion-pair, liquid-solid, or liquid-liquid chromatography) are the best methods to speciate samples since they can separate solutes on the basis of a number of parameters. Chromatographic separation can be used as part of the sample preparation step and the column effluent can be monitored with atomic spectroscopy. This mode of operation combines the excellent separation characteristics with the element selectivity of atomic spectroscopy. AAS with a flame as the atom reservoir or AES with an inductively coupled plasma have been used successfully to speciate various ultratrace elements. [Pg.251]

Equation 8.3 relies on the assumption that the calibration parameters hold to the limit of detection, which is not necessarily correct. If the calibration is taken over a very wide range, for example in some element analyses by inductively coupled plasma, the uncertainty is not constant but is proportional to the concentration. In this case it is not possible to estimate the detection limit by equation (8.3). [Pg.241]

A serious problem in LA-ICP-MS described in the literature on many occasions is the time-dependent elemental fraction (so-called ablation fractionation ) occurring during laser ablation and the transport process of ablated material, or during atomization and ionization processes in the inductively coupled plasma.20-22 Numerous papers focus on the study of fraction effects in LA-ICP-MS as a function of experimental parameters applied during laser ablation (such as laser energy, laser power density, laser pulse duration, wave length of laser beam, ablation spot size,... [Pg.390]

For a given ICP-OES instrument, the intensity of an analyte line is a complex function of several factors. Some adjustable parameters that affect the ICP source are the radiofrequency power coupled into the plasma (usually about 1 kW), the gas flow rates, the observation height in the lateral-viewing mode and the solution uptake rate of the nebuliser. Many of these factors interact in a complex fashion and their combined effects are different for dissimilar spectral lines. The selection of an appropriate combination of these factors is of critical importance in ICP-OES. This issue will be addressed in Chapter 2, where experimental designs and optimisation procedures will be discussed. Many examples related to ICP and other atomic spectrometric techniques will be presented. [Pg.15]


See other pages where Plasma coupling parameter is mentioned: [Pg.119]    [Pg.120]    [Pg.120]    [Pg.122]    [Pg.119]    [Pg.120]    [Pg.120]    [Pg.122]    [Pg.131]    [Pg.135]    [Pg.379]    [Pg.141]    [Pg.477]    [Pg.891]    [Pg.130]    [Pg.57]    [Pg.359]    [Pg.8]    [Pg.382]    [Pg.357]    [Pg.8]    [Pg.297]    [Pg.491]    [Pg.522]    [Pg.411]    [Pg.371]    [Pg.315]    [Pg.76]    [Pg.340]    [Pg.12]    [Pg.25]    [Pg.162]    [Pg.113]    [Pg.206]    [Pg.153]    [Pg.207]    [Pg.166]    [Pg.30]    [Pg.30]    [Pg.84]    [Pg.229]    [Pg.233]    [Pg.298]    [Pg.130]   