Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Oxygen sensors sensor element

In phase-fluorimetric oxygen sensors, active elements are excited with periodically modulated light, and changes in fluorescence phase characteristics are measured. The delay or emission (phase shift, ( ), measured in degrees angle) relates to the lifetime of the dye (x) and oxygen concentration as follows ... [Pg.504]

Electrolytes, oxygen sensors, fuel cells, electronic conduction coatings, and furnace elements. [Pg.313]

Another possibility is to immobilise enzymes either on the sensor element itself or in the vicinity of the sensing element. The operation principle is in most cases a semi-continuous spectral difference measurement in combination with a kinetic data evaluation. A sample containing the analyte of interest is recorded by the sensor immediately after contact with the sample and again after a certain time. Provided that no other changes in the composition of the sample occur over time, the spectral differences between the two measurements are characteristic for the analyte (and the metabolic products of the enzymatic reaction) and can quantitatively evaluated. Provided that suitable enzymes are available that can be immobilised, this may be a viable option to build a sensor, in particular when the enzymatic reaction can not (easily) be monitored otherwise, e.g. by production or consumption of oxygen or a change of pH. In any case, the specific properties and stumbling blocks related to enzymatic systems must be observed (see chapter 16). [Pg.141]

Galvanic cells with solid Zr02 (+CaO) electrolyte are used as the oxygen sensor for high temperature applications. The oxygen sensor enables determination of the activity of a metal element in an alloy. Consider the following cell ... [Pg.258]

The measurement system developed, as shown in Figure 5, is introduced into the furnace on level SCCo i so that the ceramic tip is in the gas flow. The key elements of the measurement equipment are a suction pyrometer for the temperature measurement, a wide-range oxygen sensor (BOSCH LSU4) for the fast oxygen measurement, and a thermal conductivity detector (TCD) to measure the transient response of the Helium tracer concentration. For the determination of the transient response of the TCD measurement system itself Helium tracer was injected Just at the inlet of the suction pyrometer. In Figure 7 a typical transient response of the TCD measurement system is shown (curve with index SCCi . [Pg.577]

FIGURE 4.5 Sideway view of zirconia single-crystal sensor elements and oxygen probe. [Pg.145]

Development of ionic conductors based on stabilized zirconia has reached a level of maturity, where most of the research on such materials concentrates mainly on obtaining incremental empirical improvements in conductivity by better processing control and refinement of the microstructure of the solid electrolyte and SE. Further increases in the conductivity are important in terms of enhancing the efficiency of systems such as O2 sensors, zirconia-based mixed-potential gas sensors, electrochemical oxygen pumps, heating elements, and fuel cells [4-7]. The systematic errors, as have been considered before, are errors with a known determined functional connection with the source of their cause, and the conformity of their appearance can be definitely described. [Pg.232]

Sensor elements in thimble-type 02 sensors represent about 75% of the oxygen sensor market today. These elements are mainly shaped by dry pressing and grinding of granulated Zr02. [Pg.166]

A semi-permeable membrane will shield sensor elements from mechanical trauma, and from the harsh environment of the tissue, including attack from cells and their reactive oxygen species, and protein and platelet deposition (biofouling). [Pg.295]

Electrochemical gas sensors detect gases based on the electromotive force(EMF) or the current of an electrochemical cell due to the electrochemical reaction of a particular gas. Solid electrolyte which a specific ion can selectively permeate is used as a diaphragm. Potentiometric type gas sensors have been most widely adopted. Among them potentiometric oxygen sensors composed of partial stabilized zirconia have already had practical application and heen extensively used for the feedback control of the air-fuel ratio of automobile engines. The oxygen sensor elements are composed of the following electrochemical cell. [Pg.239]


See other pages where Oxygen sensors sensor element is mentioned: [Pg.432]    [Pg.75]    [Pg.385]    [Pg.338]    [Pg.377]    [Pg.716]    [Pg.152]    [Pg.1771]    [Pg.1854]    [Pg.39]    [Pg.52]    [Pg.72]    [Pg.524]    [Pg.136]    [Pg.3425]    [Pg.432]    [Pg.344]    [Pg.345]    [Pg.24]    [Pg.112]    [Pg.112]    [Pg.386]    [Pg.404]    [Pg.283]    [Pg.135]    [Pg.144]    [Pg.144]    [Pg.202]    [Pg.205]    [Pg.205]    [Pg.206]    [Pg.98]    [Pg.488]    [Pg.490]    [Pg.424]    [Pg.492]    [Pg.3424]    [Pg.72]    [Pg.76]   
See also in sourсe #XX -- [ Pg.39 ]




SEARCH



Oxygen element

Oxygen elemental

Oxygen sensors

Sensors sensor element

© 2024 chempedia.info