Optimum absorbance

An appropriate procedure for executing the design of an absorber-stripper system is to set up a carefully selected series of design cases and then evaluate the investment costs, the operating costs, and the operability of each case. Some of the economic factors that need to be considered in selec ting the optimum absorber-stripper design are discussed later in the subsec tion Economic Design of Absorption Systems. ... [Pg.1352]

We keep learning more about the history of noise calculations. It seems that the topic of the noise of a spectrum in the constant-detector-noise case was addressed more than 50 years ago [1], Not only that, but it was done while taking into account the noise of the reference readings. The calculation of the optimum absorbance value was performed using several different criteria for optimum . One of these criteria, which Cole called the Probable Error Method, gives the same results that we obtained for the optimum transmittance value of 32.99%T [2], Cole s approach, however, had several limitations. The main one, from our point of view, is the fact that he directed his equations to represent the absorbance noise as soon as possible in his derivation. Thus his derivation, as well as virtually all the ones since then, bypassed consideration of the behavior of noise of transmittance spectra. This, coupled with the fact that the only place we have found that presented an expression for transmittance noise had a typographical error as we reported in our previous column [3], means that as far as we know, the correct expression for the behavior of transmittance noise has still never been previously reported in the literature. On the other hand, we do have to draw back a bit and admit that the correct expression for the optimum transmittance has been reported. [Pg.293]

A 5% soln of the sample in 2-nitropropane and 20% soln of the sample in benzene were prepd for the analysis. If, when using these solns, a measurement fell outside of absorbance values 0.19— 0.70 (65% 20% transmittance), an addnl soln was used to bring the readings within the limits. (Optimum absorbance values are around 0.43 or 37% transmittance). With the 0.2Q9mm cell, the absorbance of the benz soln was measured at the peak of the 9.20/1 band and the absorbance... [Pg.144]

The sensitivity should be such that the desired or optimum absorbance concentration relationship is achieved and sustained from determination to determination. [Pg.32]

Performance and Diode Parameters. For finding the optimum absorber composition, organic solar cells of the type A with various [CuPc] [C60] ratios were prepared at a non-optimised substrate temperature. The Eff behaviour with the absorber composition (Fig. la) is dominated by the behaviour of the Jso and FF [4], In the compositional range investigated, 0.2 < [CuPc]/([CuPc] + [C60]) < 0.8, the devices V00 is almost constant taking values of about 400 mV (not shown). An efficiency of 1.6% is achieved in Fig. la at a [CuPc] [C60] composition of about 1 1 (by weight) [4], The diode quality factor, n. of the devices decreases from 2.6-2.7 at the either minimum of CuPc or C6o content to 1.8 at 1 1 absorber composition. At the same time, the OSCs series resistance decreases almost symmetrically from 0.34-0.38 Q x cm2 at a content of 17% of either CuPc or C to -0.2 Q x cm2 at an identical content of CuPc and C6o-... [Pg.171]

Fig. 2.9 The function Ar(0) for Fe (14-4 keV) plotted for four values ol to show the optimum absorber thickness. Fig. 2.9 The function Ar(0) for Fe (14-4 keV) plotted for four values ol to show the optimum absorber thickness.
Mass-absorption coefficients at different wavelengths for the various elements are available in various handbooks such as those in the bibliography at the end of this chapter. As in conventional spectrophotometry (Chap. 7), the optimum absorbance range for x-ray absorption analysis is about 0.1 to I. [Pg.413]

Plastic materials, even if they appear transparent in the visible spectrum, absorb energy in the infrared region. The amount of absorbance at any wavelength can be predicted from the IR spectrum of the material. Although the material may absorb over a broad range, each material has an optimum absorbance, a frequency at which it absorbs most strongly. [Pg.269]

Warburton, G. B. (1982). Optimum absorber parameters forvarious combinations ofiesponse and excitation parameters. Earthquake Engineering Structural Dyimmics, 10, 381—401. doi 10.1002/ eqe.4290100304... [Pg.177]

Some simplified cases can be considered. In the first case, all absorbances of the material are the same. This is a relatively good assumption, NIR spectra being relatively featureless. The minimum concentration errors occur at the classical optimum absorbance of 0.434 in this boundary case. In another special case, one term is considered much larger than the other ones, this being the case of one strong absorbance band dominating the spectrum with the other wavelengths used as references. Equation (37.4) is reduced to... [Pg.724]

The optimum thickness for measuring the spectrum of any solute depends on the absorptivity of the solvent It is well known from many textbooks on instrumental analysis that the optimum pathlength of a cell should be such that the transmittance of the solvent should be about He, where e is the base of Naperian logarithms. Thus, the optimum absorbance, Aopt, of the solvent should be logioc, or 0.4... [Pg.256]

In order to keep sufficient absorption intensity and to detect VCD corresponding to a difference on the order of 10 " to 10 of the peak intensity, it is known empirically that the optimum absorbance of a band is around 0.4. The absorbance should never exceed 1.0 and not fall below 0.1. To obtain a high-quality VCD spectmm, it is most important to prepare the sample at an appropriate optimum concentration and to use a cell of appropriate pathlength. [Pg.329]

TZT is clear, low viscosity liquid with optimum absorbance at 250-300 nm. It is highly soluble and highly reactive with a flash point of 140C. [Pg.29]

Warburton G (1981) Optimum absorber parameters for minimizing vibration response. Earthquake Eng Struct... [Pg.3814]

Warburton G (1982) Optimum absorber parameters for various combinations of response and excitation parameters. Earthquake Eng Struct Dyn 10(3) 381 01 Warminski J, Kecik K (2009) Instabilities in the main parametric resonance area of a mechanical system with a pendulum. J Sound Vib 322(3) 612-628 Wiesner KB (1979) Tuned mass dampers to reduce building wmd motion. In ASCE convention and exposition, vol 3510. ASCE, Boston... [Pg.3814]

This method is the usual one for analysing the manganese content of steel. The initial step is to oxidise and remove organic matter (or O in steels). Persulphate then oxidises Mn to permanganate. The latter is then determined spectrophotometrically when dilution is necessary to obtain an optimum absorbance. The modification discussed in Sec.2.4.1 for strongly absorbing solutions could be used here. [Pg.171]


See other pages where Optimum absorbance is mentioned: [Pg.800]    [Pg.804]    [Pg.46]    [Pg.223]    [Pg.253]    [Pg.205]    [Pg.22]    [Pg.355]    [Pg.379]    [Pg.51]    [Pg.225]    [Pg.223]    [Pg.253]    [Pg.274]    [Pg.378]    [Pg.34]    [Pg.134]    [Pg.457]    [Pg.568]    [Pg.194]    [Pg.507]    [Pg.729]    [Pg.250]    [Pg.151]   