The compressibilities of solvents vary significantly from one solvent to another. The compressibility of cyclohexane is about 0.67% per thousand p.s.i. change in pressure [11] and, thus, for a column operated at 6,000 p.s.i. (mean pressure 3,000 p.s.i.), there will be an error in retention volume measurement of about 2%. In a similar manner, n-heptane has a compressibility of about 1.0% per 1,000 p.s.i. change in pressure [11] and, under similar circumstances, would give an error of about 3% in retention volume measurement. Fortunately, as already discussed in Part 1 of this book, there are other retention parameters that can be used for solute... [Pg.273]

Turntable Vessel volume Operation volume Vessel material Max. temperature Temp, measurement 3 x 96-well plates 1 mL min. 0.1 mL glass 150 °C fiber optic 52 x 50 mL max. 30 mL glass or PFA 150 °C fiber optic 120 x 15 mL max. 10 mL glass or PFA 150 °C fiber optic... [Pg.41]

The estimation of the overall precision of a methodfrom its unit operations A frequent problem in analysis is the estimation of the overall precision of a method before it has been used or when insufficient data are available to carry out a statistical analysis. In these circumstances the known precision limits for the unit operations of the method (volume measurement, weighing, etc.) may be used to indicate its precision. Table 2.6 gives the normal precision limits for Grade A volumetric equipment. [Pg.639]

For gravimetric analysis, a solution may be needed to react with the analyte. Otherwise it consists of just physical separation operations and usually initial and final weight measurements. For titrimetric analysis, solutions are always needed to react with the analyte and these solutions must be standardized. Also, a critical measurement is a volume measurement (buret reading). [Pg.507]

The measuring cell is made from Pyrex. The operational volume of the test soludon is 10 ml. The cell is carefully stoppered, and a slow flow of dry Nj is maintained inside it. This cell is enclosed by a thermostatic chamber that controls the temperature of the sample. This chamber is isolated from the surrounding atmosphere by a vacuum jacket. The sample, which is continuously stirred magnetically, can be thermostatted from -1-50 to -45 0.05°C with a liquid thermostat. The temperature is... [Pg.297]

Figure 2.2-1 illustrates how arsenic wastewater flows through that facility. The first three arsenic sources were thought to be minor and composed of soluble araenic. These waste streams flow directly to the HF preholding tank and are not involved in the Slurry Recovery process. Sample acquisition for these sources required the operator to perform the wash process in a container with graduations on the sides for volume measurement. Samples were taken after the processes were completed. Arsenic analysis waa done on the measured wash solution and with this analysis and the number of ingots or wafers cleaned or etched, a total arsenic contribution was calculated. [Pg.349]

In the alternative method (85), a second sampler, consisting of a Teflon particle filter followed by a quartz filter, is operated in parallel with a quartz-filter sampler. The carbon recovered from the quartz backup filter of this second sampler is subtracted from the organic C determination of the first sampler (Q - TQ strategy). The rationale for this alternative approach is to minimize the extent of sorption of vapor-phase carbon on the first (particle-collection) filter, which, otherwise, might significantly diminish the amount retained on the backup quartz filter. The need for an additional sampler and very accurate air volume measurements is a disadvantage. [Pg.44]

It is worth describing other operations where differences between the chemist s laboratory and the chemical engineer s pilot plant and plant create the need for different approaches. Pumping, flow measurement, and reactor volume measurement are a few of the more common operations deserving the chemist s attention. [Pg.195]

In a point of validation it is worth saying that all weight or volume measurement devices need to be well maintained, calibrated, proven, and regularly audited to ensure that the device is delivering what the operations people running a process batch sheet say it is delivering. [Pg.198]

After maintenance or repair, the door will be closed and subsequently locked, and inlet and outlet valves are opened to start the purging procedure and subsequent normal operation. The mode of operation is leakage compensation, i.e. the protective gas outlet pipe and the common purge flow or volume measuring device are active during purging only. [Pg.158]

The physical model of the reactor is a 350 mm high cylindrical vessel, with a diameter of 200 mm and an elliptical bottom. The operation volume is V = 12 10 m. The entrance of the reactants is placed near the middle of the reactor, more exactly at 130 mm from the bottom. The reactor s exit is positioned on the top of the vessel but below the liquid level. At the vessel centre is placed a mixer with three helicoidal paddles with d/D = 0.33. It operates with a rotation speed of 150 mirnf In order to establish the reactor flow model, this is filled with pure water which continuously flushes through the reactor at a flow rate of 6.6 10 5 m /s (similar to the reactants flow rate). At time t = 0, a unitary impulse of an NaCl solution with a Cq = 3.6 kg/m is introduced into the reactor input. The time evolution of the NaCl concentration at the exit flow of the reactor is measured by the conductivity. Table 3.5 gives the data that show the evolution of this concentration at the reactor exit. [Pg.88]

In the laboratory, the density of a cement slurry is usually derived from the measured mass or volume of the different ingredients and from their respective densities. When a measurement is performed, it is usually done with pressurized equipment like a pressurized mud balance (Appendix C of reference 6) as cement slurries always contain a small quantity of air bubbles (these are trapped into the slurry and difficult to eliminate because of the fluid yield stress). In the field, measuring slurry density is a key issue as it is much more cumbersome if not impossible (for continuous mix operations) to measure the mass or volume of the different ingredients. Different types of equipments are used like pressurized mud balances, radioactive densitometers, or vibrating tube devices. Once the slurry is mixed at the right density, it is of utmost importance to make sure it is stable. [Pg.606]

The cooling lock has an internal column of 300 mL and is machined from stainless steel. An outer jacket allows for a variety of coolants. The steam generator is a 2-L autoclave. A Milton-Royal high pressure pump allows for the continuous addition of water to the hot generator, ir necessary. The product collector if a pyrex vessel approximately 8 inches in diameter and 5 inches deep. Separated gas passes to a brine displacement vessel for volume measurement. A number of electrical and mechanical overrides plus barriers are designed to prevent any injury to the operator as a result of accidental discharge from the reactor or steam vessel. In addition, the control panel is located in a separate room adjacent to the reactor. [Pg.94]

P-2 Spill product In SCB -Operator Error -Mechanical Failure (manipulator) -Closed container transfer and volume measurement -Operations procedures I Visual -Spill trays lined with absorbent material so all the small volume stays in the bay -Ventilation flow (AP) to stack -Cleanup material kept In box. -Airborne release dose -Workers D -Collocated workers D -Public D -Environment D -Workers 3 Collocated Workers 3 Public 3 Environ. 3 ... [Pg.433]


See other pages where Operations volume measurement is mentioned: [Pg.220]    [Pg.8]    [Pg.41]    [Pg.48]    [Pg.215]    [Pg.113]    [Pg.244]    [Pg.260]    [Pg.220]    [Pg.208]    [Pg.387]    [Pg.393]    [Pg.408]    [Pg.223]    [Pg.253]    [Pg.577]    [Pg.92]    [Pg.76]    [Pg.246]    [Pg.514]    [Pg.11]    [Pg.225]    [Pg.433]    [Pg.81]    [Pg.1416]    [Pg.359]    [Pg.40]    [Pg.688]    [Pg.210]    [Pg.201]    [Pg.2951]    [Pg.22]    [Pg.651]   
See also in sourсe #XX -- [ Pg.652 , Pg.653 , Pg.654 , Pg.655 , Pg.656 , Pg.657 , Pg.658 , Pg.659 , Pg.660 , Pg.661 , Pg.662 , Pg.663 ]