Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operations Operation Small Change

The safety review technique is also usehil for small laboratory operations and small changes in existing processes. In these cases, the committee often consists of two or three people and any changes are often less formally recommended. [Pg.470]

Example 6.1 Rating of an Existing Naphtha-Heavier Naphtha Exchanger to Operate Under Small Changes in Flowrates... [Pg.97]

The second series of the EC funded project included five experiments for the investigation of the break location and CMT scaling (smaller CMT) on the PSIS behaviour. PACTEL operators made small changes to the CMT instrumentation to better detect CMT level and thermal stratification behaviour. The PSIS consisted of a Core Make-up Tank, which had connections to downcomer through an injection line and to one cold leg through a pressure balancing line. [Pg.176]

Thus, if the chromosome is represented as a bit string, the mutation operator will change one bit in the string as illustrated in Figure 9-30. Usually, the mutation operator is applied with only a small probability. [Pg.470]

These chemical effects become important in medicine because living systems operate mostly through the reactions of enzymes, which catalyze all sorts of metabolic reactions but are very sensitive to small changes in their environment. Such sensitivity can lead to preferential absorption of some deleterious isotopes in place of the more normal, beneficial ones. One example in metabolic systems can be found in the incorporation of a radioactive strontium isotope in place of calcium. [Pg.364]

Whereas automotive batteries have the majority of the market, other types of lead—acid batteries, such as sealed and small maintenance-free varieties, are making inroads into various appHcations. The automotive battery s operating environment has changed substantially in the last 10 years. Underhood temperature has risen and electrical loads have increased. This trend is expected to continue as car manufacturers reevaluate thek design strategies and objectives. Battery design is changing to meet these needs. [Pg.579]

It can be assumed that P,Jp, and for the cascade have been specified, and that the cost of feed and the cost per unit of separative work, the product of separative capacity and time, are known. The basic assumption is that the unit cost of separative work remains essentially constant for small changes ia the total plant size. The cost of the operation can then be expressed as the sum of the feed cost and cost of separative work ... [Pg.78]

Open-Loop versus Closed-Loop Dynamics It is common in industry to manipulate coolant in a jacketed reacdor in order to control conditions in the reacdor itself. A simplified schematic diagram of such a reactor control system is shown in Fig. 8-2. Assume that the reacdor temperature is adjusted by a controller that increases the coolant flow in proportion to the difference between the desired reactor temperature and the temperature that is measured. The proportionality constant is K. If a small change in the temperature of the inlet stream occurs, then depending on the value or K, one might observe the reactor temperature responses shown in Fig. 8-3. The top plot shows the case for no control (K = 0), which is called the open loop, or the normal dynamic response of the process by itself. As increases, several effects can be noted. First, the reactor temperature responds faster and faster. Second, for the initial increases in K, the maximum deviation in the reactor temperature becomes smaller. Both of these effects are desirable so that disturbances from normal operation have... [Pg.718]

Two variations of the technique exists isocratic elution, when the mobile phase composition is kept constant, and gradient elution, when the mobile phase composition is varied during the separation. Isocratic elution is often the method of choice for analysis and in process apphcations when the retention characteristics of the solutes to be separated are similar and not dramaticallv sensitive to vei y small changes in operating conditions. Isocratic elution is also generally practical for systems where the equilibrium isotherm is linear or nearly hnear. In all cases, isocratic elution results in a dilution of the separated produces. [Pg.1530]

Pilot-operated valves may be satisfactorily used in vapor or liquid services up to a maximum back pressure (superimposed plus built-up) of 50% of set pressure, provided that the back pressure is incorporated into the sizing calculation. At higher back pressures, capacity becomes increasingly sensitive to small changes in back pressure. As an exception, back pressure up to 7% of set pressure may be used, provided that this disadvantage is recognized. [Pg.164]

That is to say, the meaning of stability of scheme (21) is that a solution (21) depends continuously on the right-hand side and this dependence is uniform in the parameter h. This implies that a small change of the right-hand side results in a small change of the solution. If the scheme is solvable and stable, it is correct. Note that the uniqueness of the scheme (21) solution is a consequence of its solvability and stability and, hence, we might get rid of the uniqueness requirement in condition (1). Indeed, assume to the contrary that there were two solutions to equation (21), say and By the linearity property of the operator A, their difference = y — yf should satisfy the homogeneous equation... [Pg.127]


See other pages where Operations Operation Small Change is mentioned: [Pg.186]    [Pg.24]    [Pg.181]    [Pg.2778]    [Pg.551]    [Pg.80]    [Pg.182]    [Pg.353]    [Pg.312]    [Pg.188]    [Pg.670]    [Pg.78]    [Pg.2892]    [Pg.109]    [Pg.175]    [Pg.19]    [Pg.27]    [Pg.517]    [Pg.795]    [Pg.924]    [Pg.1662]    [Pg.1699]    [Pg.2428]    [Pg.2577]    [Pg.40]    [Pg.351]    [Pg.134]    [Pg.258]    [Pg.465]    [Pg.48]    [Pg.263]    [Pg.632]    [Pg.435]    [Pg.983]    [Pg.781]    [Pg.13]    [Pg.225]    [Pg.76]   


SEARCH



Operational Changes

Small operations

© 2024 chempedia.info