Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Observation light sources

The R,G,B values of the Berger formula measured by tristimulus colorimeters are linearly related to the X,Y,Z tristimulus values of the CIE system. The Stensby formula incorporates the L,a,b tristimulus values of the Hunter system. In the CIE 1982 formula, x and yn are the chromaticity coordinates of the D65 (2° or 10° observer) light source. [Pg.302]

Metameric pair n. A pair of colors, which match when viewed in a described way but which do not match if the viewing conditions are changed, thus, a metameric pair of samples exhibit the same tristimulus values for a described set of viewing conditions (observer, light source, geometry of the illumination, and viewing arrangement) but have different spectral distributions. Hence, they exhibit a match, which is conditional only. [Pg.608]

The mathematical color system is the CIE Color System based on mathematical descriptions of light sources, objects, and a standard observer. Light sources are specified by their relative energy distributions, objects are specified by their reflectance (or transmission) spectra, and the observer is specified by the CIE standard human observer tables. For color analysis, the light reflected (or transmitted) from (or through) an object is measured with a spectrophotometer. The... [Pg.1452]

A iiseUfl light source is the helium resonance lamp which produces light of wavelength 58.4 nm or a photon energy of 21.2 eV, enough to ionize any neutral molecule. Often several peaks can be observed in the photoelectron spectnim... [Pg.1124]

A rapid method to determine the calcium content of lead alloys is a Hquid-metal titration using lead—antimony (1%) (9). The end point is indicated by a gray oxide film pattern on the surface of a sohdifted sample of the metal when observed at a 45° angle to a light source. The basis for the titration is the reaction between calcium and antimony. The percentage of calcium in the sample can be calculated from the amount of antimony used. If additional calcium is needed in the alloy, the melt is sweetened with a lead—calcium (1 wt %) master alloy. [Pg.59]

In the laboratory, RI is measured using a refractometer. The instrument has two prisms and a light source. The technician spreads a small amount of sample on the faces of both prisms in the refractometer. The light is then directed at the sample and the scale is read. The observed scale is then converted to a refractive index with tables supplied with the instrument and corrected for the sample temperaturi. ... [Pg.50]

Our short review of standardization procedures starts again with illumination. Figure 1.4 shows the dispersed spectrum of the light source which is most relevant for observers daylight. Most instruments use incandescent lamps that emit very weakly in the blue and UV regions and are therefore well suited in situations where no fluorescence should be excited. [Pg.17]

The CIELAB system (1976) strictly standardizes the light source and the observer. CIE recommends three standard sources, A is an incandescent lamp, and B and C are lamps provided with different two-cell Davis-Gibson liquid hlters that simulate noon daylight and average daylight, respectively. Since the main object of the system is to obtain colorimetric results for normal tri-chromats (people with normal color vision), the standard observer must represent the human population with normal... [Pg.19]

A nano-light-source generated on the metallic nano-tip induces a variety of optical phenomena in a nano-volume. Hence, nano-analysis, nano-identification and nanoimaging are achieved by combining the near-field technique with many kinds of spectroscopy. The use of a metallic nano-tip applied to nanoscale spectroscopy, for example, Raman spectroscopy [9], two-photon fluorescence spectroscopy [13] and infrared absorption spectroscopy [14], was reported in 1999. We have incorporated Raman spectroscopy with tip-enhanced near-field microscopy for the direct observation of molecules. In this section, we will give a brief introduction to Raman spectroscopy and demonstrate our experimental nano-Raman spectroscopy and imaging results. Furthermore, we will describe the improvement of spatial resolution... [Pg.24]

It is certainly clear that a coulometric titration, like any other type of titration, needs an end-point detection system in principle any detection method that chemically fits in can be used, be it electrometric, colorimetric, photoabsorptionmetric, etc. for instance, in a few cases the colour change of the reagent generated (e.g., I2) may be observed visually, or after the addition of a redox, metal or pH indicator the titration end-point can be detected photoabsorptiometrically by means of a light source and photocell combination. Concerning the aforementioned coulometric titration of Fe(II), it is... [Pg.236]


See other pages where Observation light sources is mentioned: [Pg.73]    [Pg.75]    [Pg.317]    [Pg.213]    [Pg.73]    [Pg.75]    [Pg.317]    [Pg.213]    [Pg.1263]    [Pg.1263]    [Pg.2124]    [Pg.2498]    [Pg.2955]    [Pg.43]    [Pg.428]    [Pg.68]    [Pg.119]    [Pg.474]    [Pg.257]    [Pg.1110]    [Pg.182]    [Pg.645]    [Pg.24]    [Pg.250]    [Pg.130]    [Pg.292]    [Pg.78]    [Pg.159]    [Pg.334]    [Pg.347]    [Pg.351]    [Pg.196]    [Pg.22]    [Pg.25]    [Pg.104]    [Pg.456]    [Pg.145]    [Pg.202]    [Pg.386]    [Pg.171]    [Pg.117]    [Pg.694]   
See also in sourсe #XX -- [ Pg.75 ]




SEARCH



Light sources

© 2024 chempedia.info