Number of ions

One can write acid-base equilibrium constants for the species in the inner compact layer and ion pair association constants for the outer compact layer. In these constants, the concentration or activity of an ion is related to that in the bulk by a term e p(-erp/kT), where yp is the potential appropriate to the layer [25]. The charge density in both layers is given by the algebraic sum of the ions present per unit area, which is related to the number of ions removed from solution by, for example, a pH titration. If the capacity of the layers can be estimated, one has a relationship between the charge density and potential and thence to the experimentally measurable zeta potential [26]. [Pg.178]

For an electrolyte solution containing both anions and cations, with the tennmal velocity of the cations being and the number of ions of charge z Cq per unit volume being Et, the product corresponds just... [Pg.570]

Much of the energy deposited in a sample by a laser pulse or beam ablates as neutral material and not ions. Ordinarily, the neutral substances are simply pumped away, and the ions are analyzed by the mass spectrometer. To increase the number of ions formed, there is often a second ion source to produce ions from the neutral materials, thereby enhancing the total ion yield. This secondary or additional mode of ionization can be effected by electrons (electron ionization, El), reagent gases (chemical ionization. Cl), a plasma torch, or even a second laser pulse. The additional ionization is often organized as a pulse (electrons, reagent gas, or laser) that follows very shortly after the... [Pg.10]

If there were only one such tip electrode, the yield of ions would be very limited (small surface area and small numbers of ions formed per unit time). To increase ion yield, it is better to use... [Pg.24]

The ion current resulting from collection of the mass-separated ions provides a measure of the numbers of ions at each m/z value (the ion abundances). Note that for this ionization method, all ions have only a single positive charge, z = 1, so that m/z = m, which means that masses are obtained directly from the measured m/z values. Thus, after the thermal ionization process, m/z values and abundances of ions are measured. The accurate measurement of relative ion abundances provides highly accurate isotope ratios. This aspect is developed more fully below. [Pg.46]

Schematic diagram showing the development of a dipolar field and ionization on the surface of a metal filament, (a) As a neutral atom or molecule approaches the surface of the metal, the negative electrons and positive nuclei of the neutral and metal attract each other, causing dipoles to be set up in each, (b) When the neutral particle reaches the surface, it is attracted there by the dipolar field with an energy Q,. (c) If the values of 1 and <() are opposite, an electron can leave the neutral completely and produce an ion on the surface, and the heat of adsorption becomes Q,. Similarly, an ion alighting on the surface can produce a neutral, depending on the values of I and <(), On a hot filament the relative numbers of ions and neutrals that desorb are given by Equation 7.1,which includes the difference, I - <(), and the temperature, T,... Schematic diagram showing the development of a dipolar field and ionization on the surface of a metal filament, (a) As a neutral atom or molecule approaches the surface of the metal, the negative electrons and positive nuclei of the neutral and metal attract each other, causing dipoles to be set up in each, (b) When the neutral particle reaches the surface, it is attracted there by the dipolar field with an energy Q,. (c) If the values of 1 and <() are opposite, an electron can leave the neutral completely and produce an ion on the surface, and the heat of adsorption becomes Q,. Similarly, an ion alighting on the surface can produce a neutral, depending on the values of I and <(), On a hot filament the relative numbers of ions and neutrals that desorb are given by Equation 7.1,which includes the difference, I - <(), and the temperature, T,...
Therefore, the ratio of the number of ions to the number of neutrals desorbing from a heated filament depends not only on the absolute temperature but also on the actual surface coverage of ions and neutrals on the filament (C, C ) and crucially on the difference between the ionization energy and work function terms, I and (j). This effect is explored in greater detail in the following illustrations. [Pg.49]

As ions and neutrals evaporate from a heated filament surface, the amount of sample decreases and the surface densities (C, Cq) must decrease. Therefore, Equation 7.1 covers two effects. The first was discussed above and concerns the changing value for the ratio n+/n° as the temperature of the filament is varied, and the other concerns the change in the total number of ions desorbing as the sample is used up. The two separate effects are shown in Figure 7.8a,b. Combining the two effects (Figure 7.8c) reveals that if the temperature is increased to maintain the flow of ions, which drops naturally as the sample is used up (time), then eventually the flow of ions and neutrals becomes zero whatever the temperature of the filament because the sample has disappeared from the filament surface. [Pg.51]

In many applications in mass spectrometry (MS), the sample to be analyzed is present as a solution in a solvent, such as methanol or acetonitrile, or an aqueous one, as with body fluids. The solution may be an effluent from a liquid chromatography (LC) column. In any case, a solution flows into the front end of a mass spectrometer, but before it can provide a mass spectrum, the bulk of the solvent must be removed without losing the sample (solute). If the solvent is not removed, then its vaporization as it enters the ion source would produce a large increase in pressure and stop the spectrometer from working. At the same time that the solvent is removed, the dissolved sample must be retained so that its mass spectrum can be measured. There are several means of effecting this differentiation between carrier solvent and the solute of interest, and thermospray is just one of them. Plasmaspray is a variant of thermospray in which the basic method of solvent removal is the same, but the number of ions obtained is enhanced (see below). [Pg.71]

This chapter should be read in conjunction with Chapter 6, Coronas, Plasmas, and Arcs. A plasma is defined as a gaseous phase containing neutral molecules, ions, and electrons. The numbers of ions and electrons are usually almost equal. In a plasma torch, the plasma is normally formed in a monatomic gas such as argon flowing between two concentric quartz tubes (Figure 14.1). [Pg.87]

The array detector (collector) consists of a number of ion-collection elements arranged in a line each element of the array is an electron multiplier. Another type of array detector, the time-to-digital converter, is discussed in Chapter 31. [Pg.206]

The major advantage of array detectors over point ion detectors lies in their ability to measure a range of m/z values and the corresponding ion abundances all at one time, rather than sequentially. For example, suppose it takes 10 msec to measure one m/z value and the associated number of ions (abundance). To measure 100 such ions sequentially with a point ion detector would necessitate 1000 msec (1 sec) for the array detector, the time is still 10 msec because all ions arrive at the same time. Therefore, when it is important to be able to measure a range of ion m/z values in a short space of time, the array detector is advantageous. [Pg.209]

Ions in a TOF analyzer are temporally separated according to mass. Thus, at the detector all ions of any one mass arrive at one particular time, and all ions of other masses arrive at a different times. Apart from measuring times of arrival, the TDC device must be able to measure the numbers of ions at any one m/z value to obtain ion abundances. Generally, in TOF instruments, many pulses of ions are sent to the detector per second. It is not unusual to record 30,000 spectra per minute. Of course, each spectmm contains few ions, and a final mass spectrum requires addition of all 30,000 spectra to obtain a representative result. [Pg.220]

A mass spectrum is a chart of ion abundances versus m/z values. It is shown above that the TDC measures ion arrival times, which are converted directly into m/z values. Notionally, the number of ions arriving at the detector at any one m/z value is equal to the number of events recorded (one... [Pg.223]

A mass spectrum consists of peaks corresponding to ions. The position of a peak on the x-axis is proportional to its mass (strictly, its m/z value), while the height of the peak on the y-axis gives the number of ions (abundances) at a particular m/z. The ions giving rise to the spectrum are formed in an ion source and are passed through an analyzer for measurement of m/z and into a detector for measurement of abundance (Figure 32.1). [Pg.225]

Schematic diagram of a mass spectrometer. After insertion of a sampie (A), it is ionized, the ions are separated according to m/z value, and the numbers of ions (abundances) at each m/z value are plotted against m/z to give the mass spectrum of A. By studying the mass spectrum, A can be identified,... Schematic diagram of a mass spectrometer. After insertion of a sampie (A), it is ionized, the ions are separated according to m/z value, and the numbers of ions (abundances) at each m/z value are plotted against m/z to give the mass spectrum of A. By studying the mass spectrum, A can be identified,...
A mass spectrum consists of a series of peaks at different m/z values, with the height of the peak proportional to the number of ions. A partial mass spectrum is shown in Figure 44.3 and is seen to be an analog signal that varies as the peaks rise from and fall to the baseline. Between the peaks are relatively long intervals when there is only the baseline. As described above, the signal is first digitized. [Pg.317]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

As the name implies, thermospray uses heat to produce a spray of fine droplets. Plasmaspray does not produce the spray by using a plasma but, rather, the droplets are produced in a thermospray source and a plasma or corona is used afterward to increase the number of ions produced. [Pg.392]

To increase the number of ions, a plasma or corona discharge is produced in the mist issuing from the capillary. The electrical discharge induces more ionization in the neutrals accompanying the few thermospray ions. This enhancement increases the ionization of sample molecules and makes the technique much more sensitive to distinguish it from simple thermospray, it is called plasmaspray. [Pg.392]

A chart showing the number of ions (abundance) arriving at the collector and their respective m/z values is a mass spectrum. [Pg.405]

The magnitude of the current flow is proportional to the number of ions arriving at the array element per unit time. [Pg.409]


See other pages where Number of ions is mentioned: [Pg.230]    [Pg.484]    [Pg.570]    [Pg.1804]    [Pg.1827]    [Pg.27]    [Pg.395]    [Pg.243]    [Pg.12]    [Pg.14]    [Pg.35]    [Pg.36]    [Pg.36]    [Pg.63]    [Pg.89]    [Pg.113]    [Pg.135]    [Pg.136]    [Pg.196]    [Pg.209]    [Pg.209]    [Pg.219]    [Pg.224]    [Pg.227]    [Pg.322]    [Pg.351]    [Pg.408]   
See also in sourсe #XX -- [ Pg.15 ]




SEARCH



Coordination number of ions

Coordination number of metal ion

Number of Atoms Packed in First Coordination Sphere around Metal Ion

Number of hydrogen ions bound

The Number of Ions

Total Solvation Numbers of Ions in Electrolytes

Transference number of an ion

Transference numbers, of ions

Transport numbers of ions

Why Do Hydration Heats of Transition-Metal Ions Vary Irregularly with Atomic Number

© 2024 chempedia.info