Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Normal phase methods development

A Normal Phase Method Development Protocol for CYCLOBOND 1 2000... [Pg.463]

The field of bioanalysis remains dominated by HPLC, despite the fact that several other chromatographic forms have been interfaced to MS, which include gas chromatography, supercritical fluid chromatography, and capillary electrophoresis. The popularity of RP-LC stems from its instrumental simplicity, wide scope of application, and relative ease of method development. This section primarily focuses on RP-LC, with attention also given to the recent resurgence in normal-phase methods (NP-LC). [Pg.331]

When analytes lack the selectivity in the new polar organic mode or reversed-phase mode, typical normal phase (hexane with ethanol or isopropanol) can also be tested. Normally, 20 % ethanol will give a reasonable retention time for most analytes on vancomycin and teicoplanin, while 40 % ethanol is more appropriate for ristocetin A CSP. The hexane/alcohol composition is favored on many occasions (preparative scale, for example) and offers better selectivity for some less polar compounds. Those compounds with a carbonyl group in the a or (3 position to the chiral center have an excellent chance to be resolved in this mode. The simplified method development protocols are illustrated in Fig. 2-6. The optimization will be discussed in detail later in this chapter. [Pg.38]

Comparisons of LC and SFC have also been performed on naphthylethylcar-bamoylated-(3-cyclodextrin CSPs. These multimodal CSPs can be used in conjunction with normal phase, reversed phase, and polar organic eluents. Discrete sets of chiral compounds tend to be resolved in each of the three mobile phase modes in LC. As demonstrated by Williams et al., separations obtained in each of the different mobile phase modes in LC could be replicated with a simple CO,-methanol eluent in SFC [54]. Separation of tropicamide enantiomers on a Cyclobond I SN CSP with a modified CO, eluent is illustrated in Fig. 12-4. An aqueous-organic mobile phase was required for enantioresolution of the same compound on the Cyclobond I SN CSP in LC. In this case, SFC offered a means of simplifying method development for the derivatized cyclodextrin CSPs. Higher resolution was also achieved in SFC. [Pg.308]

Chromatography. A number of HPLC and TLC methods have been developed for separation and isolation of the brevetoxins. HPLC methods use both C18 reversed-phase and normal-phase silica gel columns (8, 14, 15). Gradient or iso-cratic elutions are employed and detection usually relies upon ultraviolet (UV) absorption in the 208-215-nm range. Both brevetoxin backbone structures possess a UV absorption maximum at 208 nm, corresponding to the enal moeity (16,17). In addition, the PbTx-1 backbone has an absorption shoulder at 215 nm corresponding to the 7-lactone structure. While UV detection is generally sufficient for isolation and purification, it is not sensitive (>1 ppm) enough to detect trace levels of toxins or metabolites. Excellent separations are achieved by silica gel TLC (14, 15, 18-20). Sensitivity (>1 ppm) remains a problem, but flexibility and ease of use continue to make TLC a popular technique. [Pg.177]

Pelander et al. [81] developed a computer program for optimization of the mobile phase composition in TLC. They used the desirability function technique combined with the PRISMA model to enhance the quahty of TLC separation. They apphed the statistical models for prediction of retardation and band broadening at different mobile phase compositions they obtained using the PRISMA method the optimum mobile phase mixtures and a good separation for cyanobacterial hepatotoxins on a normal phase TLC plate and for phenolic compound on reversed-phase layers. [Pg.93]

Applications Chromatography is a preferred technique for additive analysis as it allows both separation of additives in a mixture and subsequent quantitation. Despite the developments in GC, this technique cannot separate many polymer additives. Even with its lower efficiency in comparison to GC, HPLC is today one of the cornerstones in a polymer additive laboratory. Judging by the number of publications in recent years, HPLC is first among analytical methods for additives (confirmation/identification/quantification). Most additives may be analysed by HPLC if they can be dissolved in an HPLC solvent and absorb UV light. Typical polymer/additive analyses are carried out using LPE followed by HPLC with UV or RI detection [605-611]. Verification of the identity of an analyte is then based on a combination of retention time, UV and RI evidence. RPLC is used most frequently for polymer/additive analysis, but normal-phase and SEC are also used. Consequently, techniques for additive analysis by HPLC are legion. [Pg.246]

A simple TLC method has been developed for the separation and identification of flavons and flavon glycosides in the extract of Phillyrea latifolia L. The leaves (100 g) were defatted in 11 of chloroform for 24 h and then extracted with 2 X 11 of ethanol-water (80 20, v/v). The collected extracts were concentrated and extracted again with n-hexane to remove chlorophylls and other apolar constituents. Analytes were extracted with ethyl acetate. Both normal phase and RP-TLC have been used for the separation of flavonoids. The results are compiled in Table 2.36. It was concluded from the data that TLC can be successfully applied for the quality control of plant extracts containing various flavone derivatives [124],... [Pg.144]

Normal-phase liquid chromatography is thus a steric-selective separation method. The molecular properties of steric isomers are not easily obtained and the molecular properties of optical isomers estimated by computational chemical calculation are the same. Therefore, the development of prediction methods for retention times in normal-phase liquid chromatography is difficult compared with reversed-phase liquid chromatography, where the hydrophobicity of the molecule is the predominant determinant of retention differences. When the molecular structure is known, the separation conditions in normal-phase LC can be estimated from Table 1.1, and from the solvent selectivity. A small-scale thin-layer liquid chromatographic separation is often a good tool to find a suitable eluent. When a silica gel column is used, the formation of a monolayer of water on the surface of the silica gel is an important technique. A water-saturated very non-polar solvent should be used as the base solvent, such as water-saturated w-hexane or isooctane. [Pg.84]

Gustavson et al. (2000) developed a convenient and novel solid phase extraction (SPE) method for the removal of methyl oleate from SPMD dialysates containing PAHs. A small SPE column (1 g or 0.5 g) containing a dual-zone silica (normal phase)-based restricted-access sorbent (Diazem, Midland, MI, USA) is used for the separation. The capacity of this sorbent to remove methyl oleate is about 1.8% (lipid/sorbent wt wt ). The PAHs are eluted with 19 mL of hexane and methylene chloride (97 3 VV ) and recoveries of all PAHs are typically >72%. [Pg.112]

Matthijs, N., Perrin, C., Maftouh, M., Massart, D.L., Vander Heyden, Y. Definition and system implementation of strategies for method development of chiral separations in normal- or reversed-phase liquid chromatography using polysaccharide-based stationary phases. 7. Chromatogr. A 2004, 1041, 119-133. [Pg.210]


See other pages where Normal phase methods development is mentioned: [Pg.116]    [Pg.692]    [Pg.1668]    [Pg.374]    [Pg.2365]    [Pg.1596]    [Pg.62]    [Pg.67]    [Pg.433]    [Pg.254]    [Pg.53]    [Pg.445]    [Pg.222]    [Pg.417]    [Pg.1249]    [Pg.328]    [Pg.213]    [Pg.218]    [Pg.221]    [Pg.234]    [Pg.244]    [Pg.67]    [Pg.194]    [Pg.348]    [Pg.141]    [Pg.74]    [Pg.262]    [Pg.125]    [Pg.450]    [Pg.156]    [Pg.247]    [Pg.85]    [Pg.443]    [Pg.564]    [Pg.103]    [Pg.1]    [Pg.48]    [Pg.56]   
See also in sourсe #XX -- [ Pg.191 , Pg.192 , Pg.193 , Pg.194 , Pg.195 , Pg.196 , Pg.197 , Pg.198 , Pg.199 , Pg.200 , Pg.201 ]




SEARCH



Development phases

Method development

Method phase

Normal phase

© 2024 chempedia.info