Monitor carbon monoxide on a continuous basis at a point downstream of the combustion zone and prior to release into the atmosphere. [Pg.964]

The mercuric oxide reduction detector was originally described for monitoring carbon monoxide in clean atmospheres (13). However, because the principle of detection relies only on the transformation of HgO to Hg vapor,... [Pg.295]

FIGURE 16-14 A nondispersive IB photometer for monitoring carbon monoxide. [Pg.448]

For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm. [Pg.732]

Typical Applications These include gas sensors to monitor carbon monoxide, carbon dioxide, and hydrocarbons and biosensors to measure the absorption spectrum of blood. [Pg.1755]

The usual precautions must be observed around the high tension electrical equipment supplying power. The carbon monoxide formed, if collected in closed furnaces, is usually handled through blowers, scmbbers, and thence to a pipe transmission system. As calcium carbide exposed to water readily generates acetylene, the numerous cooling sections required must be constandy monitored for leaks. When acetylene is generated, proper precautions must be taken because of explosibiUty of air—acetylene mixtures over a wide range of concentrations (from 2.5 to 82% acetylene by volume) and the dammabiUty of 82—100% mixtures under certain conditions. [Pg.462]

A variety of instmments are available to analyze carbon monoxide in gas streams from 1 ppm to 90%. One group of analyzers determines the concentration of carbon monoxide by measuring the intensity of its infrared stretching frequency at 2143 cm . Another group measures the oxidation of carbon monoxide to carbon dioxide electrochemically. Such instmments are generally lightweight and weU suited to appHcations requiring portable analyzers. Many analyzers are equipped with alarms and serve as work area monitors. [Pg.53]

The effect of accumulation in various systems depends greatly on the quantity of pollutants involved. Many pollutants can be detected at concentrations lower than those necessary to affect human health. For pollutants which are eliminated slowly, individuals can be monitored over long periods of time to detect trends in body burden the results of these analyses can then be related to total pollutant exposure. Following are two examples of air pollutants that contribute to the total body burden for lead and carbon monoxide. [Pg.101]

The U.S. Environmental Protection Agency has established National Ambient Air Quality Standards (NAAQS) for protection of human health and welfare. These standards are defined in terms of concentration and hme span for a specific pollutant for example, the NAAQS for carbon monoxide is 9 ppmV for 8 hr, not to be exceeded more than once per year. For a state or local government to establish compliance with a National Ambient Air Quality Standard, measurements of the actual air quality must be made. To obtain these measurements, state and local governments have established stationary monitoring networks with instrumentation complying with federal specifications, as discussed in Chapter 14. The results of these measurements determine whether a given location is violating the air quality standard. [Pg.216]

Enclosed flares are composed of multiple gas burner heads placed at ground level in a staeklike enclosure that is usually refractory or ceramic lined. Many flares are equipped with automatic damper controls that regulate the supply of combustion air depending on temperature which is monitored upstream of the mixing, but inside the staek. This class of flare is becoming the standard in the industry due to its ability to more effectively eontrol emissions. Requirements on emissions includes carbon monoxide limits and minimal residence time and temperature. Exhaust gas temperatures may vary from 1,000 to 2,000 F. [Pg.487]

Emissions monitoring is essential in controlling industrial environments and processes to ensure good air quality standards are maintained. It is also required in order that the various regulations and guidelines related to air quality are met. In addition to gaseous emissions, such as sulfur dioxide, carbon monoxide, nitrogen oxides, hydrocarbons, and many others, the emissions of particulate material and heavy metals must also be controlled. [Pg.1283]

Carbon monoxide and carbon dioxide can be measured using the FTIR techniques (Fourier transform infrared techniques see the later section on the Fourier transform infrared analyzer). Electrochemical cells have also been used to measure CO, and miniaturized optical sensors are available for CO 2 monitoring. [Pg.1297]

B. Cyclohexylidenecyclohexane. In a Hanovia 450-watt immersion photochemical reactor (Note 2), equipped with a side arm attachment to monitor gas evolution, is placed 15 g. (0.068 mole) of dispiro[5.1.5.1]tetradecane-7,14-dione dissolved in 150 ml. of methylene chloride. The sample is irradiated, and carbon monoxide starts to evolve rapidly after a few minutes. Irradiation is continued until gas evolution has ceased, usually... [Pg.34]

In Mexico City, several air quality parameters are measured continuously by an Automated Monitoring Network operated by the Under Secretariat of Ecology. Carbon monoxide, particulate matter, sulfur dioxide, nitrogen oxide, and ozone are the contaminants exceeding Air Quality Standards. Emissions produced by 2.7 million vehicles and 35,000 commercial and industrial outfits are not easily dispersed in a Valley located at 2240 m and surrounded by two mountain chains which hinder air circulation. An Integral Program, recently established to alleviate pollution, is briefly described. [Pg.149]

If a potential carbon monoxide hazard is identified, or confirmed by atmospheric monitoring, the range of control techniques summarized on pages 47—51 must be applied. [Pg.63]

The catal5fsts were tested for CO oxidation in a flow reactor using a 2.5 % CO in dry air mixture at a fixed flow rate of 200 seem. Thirty milligrams of the catalyst were used for each experimental run. The reaction was conducted at 298, 323, 373 and 473 K with 75 minutes duration at each temperature. The carbon monoxide conversion to carbon dioxide was monitored by an online gas chromatogr h equipped with a CTR-1 column and a thermal conductivity... [Pg.413]

Respiratory protective equipment for use against asbestos Monitoring strategies for toxic substances Carbon monoxide... [Pg.573]

Yeom and Frei [96] showed that irradiation at 266 nm of TS-1 loaded with CO and CH3OH gas at 173 K gave methyl formate as the main product. The photoreaction was monitored in situ by FT-IR spectroscopy and was attributed to reduction of CO at LMCT-excited framework Ti centers (see Sect. 3.2) under concurrent oxidation of methanol. Infrared product analysis based on experiments with isotopically labeled molecules revealed that carbon monoxide is incorporated into the ester as a carbonyl moiety. The authors proposed that CO is photoreduced by transient Ti + to HCO radical in the primary redox step. This finding opens up the possibility for synthetic chemistry of carbon monoxide in transition metal materials by photoactivation of framework metal centers. [Pg.55]

Sodium hydrosulfite is produced through the Formate process where sodium formate solution, sodium hydroxide, and liquid sulfur dioxide reacted in the presence of a recycled stream of methanol solvent. Other products are sodium sulfite, sodium bicarbonate, and carbon monoxide. In the reactor, sodium hydrosulfite is precipitated to form a slurry of sodium hydrosulfite in the solution of methanol, methyl formate, and other coproducts. The mixture is sent to a pressurized filter system to recover sodium hydrosulfite crystals that are dried in a steam-heated rotary drier before being packaged. Heat supply in this process is highly monitored in order not to decompose sodium hydrosulfite to sulfite. Purging is periodically carried out on the recycle stream, particularly those involving methanol, to avoid excessive buildup of impurities. Also, vaporized methanol from the drying process and liquors from the filtration process are recycled to the solvent recovery system to improve the efficiency of the plant. [Pg.944]


See other pages where Monitoring-carbon monoxide is mentioned: [Pg.391]    [Pg.134]    [Pg.187]    [Pg.22]    [Pg.15]    [Pg.744]    [Pg.391]    [Pg.134]    [Pg.187]    [Pg.22]    [Pg.15]    [Pg.744]    [Pg.336]    [Pg.331]    [Pg.7]    [Pg.392]    [Pg.402]    [Pg.137]    [Pg.139]    [Pg.420]    [Pg.155]    [Pg.162]    [Pg.97]    [Pg.13]    [Pg.544]    [Pg.144]    [Pg.1292]    [Pg.771]    [Pg.958]    [Pg.176]   
See also in sourсe #XX -- [ Pg.115 ]