Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Monitor block system

Fig. 15.13 Monitor IV system, (a) Reaction sequence, (b) Block diagram of the interchangeable module design. (Courtesy of Technicon). Fig. 15.13 Monitor IV system, (a) Reaction sequence, (b) Block diagram of the interchangeable module design. (Courtesy of Technicon).
The above considerations have also been used to construct a simple method for the iterative solution of the linear block system (2.9). Let A denote the Jacobian approximation in (2.9) and A the associated matrix with Qy replaced by 0. Then the system Ax = h can be solved easily because of its nearly upper triangular block structure. On this basis, we constructed a fixed point iteration which is known to converge with contraction rate not greater than the spectral radius p(I — A A), Obviously, since y = 0 in the starting point xo, we will have p < 1 in some neighborhood, which can be monitored. [Pg.34]

The filtered water makeup systems The Disassembly Basin filtration system The MB cutting saw stops The hand-hdd gamma monitors The MB oiticality bars used in the fuel bundling process The HBBS rack spacers and fuel blocking system The shipping cask blanks and cadmium separator plates The installed gamma monitors on the machine basin equipment... [Pg.206]

Scope block will report the results of the simulation. Furthermore, they will be stored in the workspace. We select a system with a step source, a time delay, a model of the system given by a simple transfer function, and a scope as final monitoring block. In order to run, we can click on the arrow (see Figure 4.29), and we obtain the results shown in Figure 4.30. [Pg.153]

These concepts are not maintained in shutdown. Automatic actuation is blocked. Systems are out of service because of maintenance. Operators have less instrumentation operable, and some of the key variables are even not monitored. Safety studies and engineering analysis of operational events clearly confirmed those insights. [Pg.51]

Fig. 5. Block diagram of contact atomic force microscope system in which cantilever deflection monitored optically with position-sensitive photodiode... Fig. 5. Block diagram of contact atomic force microscope system in which cantilever deflection monitored optically with position-sensitive photodiode...
Provide automatic sprinkler system/inerting gas Provide deflagration vents Provide deflagration suppression system Monitor flammable atmosphere/fire Provide nitrogen blocks (nitrogen injection to stop flame propagation) or other explosion isolation measures... [Pg.51]

Figure 4-92. Block diagram of a proven digital supervisory and monitoring system for turbomaehinery trains. (Source Elliott Company.)... Figure 4-92. Block diagram of a proven digital supervisory and monitoring system for turbomaehinery trains. (Source Elliott Company.)...
Figure 19-8. A block diagram for an on-line condition monitoring system. Figure 19-8. A block diagram for an on-line condition monitoring system.
Figure 10.1. USAXS observation during straining of an SBS block copolymer. Right monitor Intensity maxima on an ellipse. Raw-data coordinate system (x,y) and radial cuts for data analysis are indicated. Middle Videotaping of sample. Left Stress-strain curve. Control booth of beamline BW4, HASYLAB, Hamburg... Figure 10.1. USAXS observation during straining of an SBS block copolymer. Right monitor Intensity maxima on an ellipse. Raw-data coordinate system (x,y) and radial cuts for data analysis are indicated. Middle Videotaping of sample. Left Stress-strain curve. Control booth of beamline BW4, HASYLAB, Hamburg...
Another possibility is to immobilise enzymes either on the sensor element itself or in the vicinity of the sensing element. The operation principle is in most cases a semi-continuous spectral difference measurement in combination with a kinetic data evaluation. A sample containing the analyte of interest is recorded by the sensor immediately after contact with the sample and again after a certain time. Provided that no other changes in the composition of the sample occur over time, the spectral differences between the two measurements are characteristic for the analyte (and the metabolic products of the enzymatic reaction) and can quantitatively evaluated. Provided that suitable enzymes are available that can be immobilised, this may be a viable option to build a sensor, in particular when the enzymatic reaction can not (easily) be monitored otherwise, e.g. by production or consumption of oxygen or a change of pH. In any case, the specific properties and stumbling blocks related to enzymatic systems must be observed (see chapter 16). [Pg.141]

Block valves are often controlled on the basis of analyzer results, such as area monitors for detecting solvent leaks, reactor analyzers for detecting runaway reactions (a block valve can be opened to add a reaction inhibitor or to turn on a deluge system), sewer analyzers for detecting high concentrations of contaminants, and vent analyzers to detect high levels of contaminants. [Pg.529]


See other pages where Monitor block system is mentioned: [Pg.305]    [Pg.305]    [Pg.88]    [Pg.311]    [Pg.434]    [Pg.205]    [Pg.541]    [Pg.401]    [Pg.149]    [Pg.407]    [Pg.458]    [Pg.65]    [Pg.64]    [Pg.188]    [Pg.618]    [Pg.432]    [Pg.1314]    [Pg.806]    [Pg.50]    [Pg.234]    [Pg.555]    [Pg.41]    [Pg.362]    [Pg.227]    [Pg.452]    [Pg.67]    [Pg.70]    [Pg.336]    [Pg.241]    [Pg.77]    [Pg.409]    [Pg.431]    [Pg.879]    [Pg.9]    [Pg.110]    [Pg.278]    [Pg.172]    [Pg.258]    [Pg.426]    [Pg.139]   
See also in sourсe #XX -- [ Pg.305 ]




SEARCH



Monitor system

Monitoring system

© 2024 chempedia.info