Microcell

Scale of Operation Voltammetry is routinely used to analyze samples at the parts-per-million level and, in some cases, can be used to detect analytes at the parts-per-billion or parts-per-trillion level. Most analyses are carried out in conventional electrochemical cells using macro samples however, microcells are available that require as little as 50 pL of sample. Microelectrodes, with diameters as small as 2 pm, allow voltammetric measurements to be made on even smaller samples. For example, the concentration of glucose in 200-pm pond snail neurons has been successfully monitored using a 2-pm amperometric glucose electrode. ... [Pg.531]

Other methods of identification include the customary preparation of derivatives, comparisons with authentic substances whenever possible, and periodate oxidation. Lately, the application of nuclear magnetic resonance spectroscopy has provided an elegant approach to the elucidation of structures and stereochemistry of various deoxy sugars (18). Microcell techniques can provide a spectrum on 5-6 mg. of sample. The practicing chemist is frequently confronted with the problem of having on hand a few milligrams of a product whose structure is unknown. It is especially in such instances that a full appreciation of the functions of mass spectrometry can be developed. [Pg.214]

Membrane, 141, 178 Mercury electrodes, 62, 108 Mercury film electrode, 76, 110 Metals, 75, 81 Metal complexes, 64 Methyl viologen, 43 Michaelis-Menten kinetics, 175 Microbalance, 52, 53 Microcells, 102 Microchip, 194, 195... [Pg.208]

A nonuniform distribution of the reactions may arise when the metal s surface is inhomogeneous, particularly when it contains inclusions of other metals. In many cases (e.g., zinc with iron inclusions), the polarization of hydrogen evolution is much lower at the inclusions than at the base metal hence, hydrogen evolution at the inclusions will be faster (Fig. 22.3). Accordingly, the rate of the coupled anodic reaction (dissolution of the base metal) will also be faster. The electrode s OCP will become more positive under these conditions. At such surfaces, the cathodic reaction is concentrated at the inclusions, while the anodic reaction occurs at the base metal. This mechanism is reminiscent of the operation of shorted galvanic couples with spatially separated reactions Metal dissolves from one electrode hydrogen evolves at the other. Hence, such inclusions have been named local cells or microcells. [Pg.382]

Procedure Cholinesterase activity in analyzed tissue or the matrix (biotest with immobilized AChE) is determined in the incubation media [consisting of substrate ATCh - 34 mmol maleate buffer 0.1 M, pH = 6.0- 6.5 ml sodium citrate 0.1 M - 0.5 ml CuS045H20 0.03M -1.0 ml distilled H20 (or inhibitor in variant with toxin analyzed) -1.0 ml potassium ferricyanide 0.005 M -1 ml.] Volume of incubation media in one test - 400 mcl. As a blank (control sample), a treatment of the exposure without the substrate is used. If inhibitory effects of allelochemical (or any toxin) are analyzed, before the substrate addition the sample was preliminary exposed to allelochemical inhibitor. Two methods for the AChE-biotests may be recommended (i) in microcells ( stationary conditions ) and (ii) in flowing columns-reactors ( dynamic conditions ). [Pg.152]

The counter electrode is the current carrying electrode and it must be inert and larger in dimension. Platinum wire or foil is the most common counter electrode. For work with micro- or ultramicroelectrode where the maximum current demand is of the order of few microamperes, the counter electrode is not necessary. At very low current, a two-electrode system with the reference electrode can function as the current-carrying electrode with very little change in the composition of the reference electrode. Many commercial glucose sensors and on-chip microcells have such electrode configuration. [Pg.668]

Synonyms Calcium hydrosilicate calsil Microcel Calflo E Florite R Marimet 45 tobermorite (crystalline form of synthetic calcium silicate) wollastonite is a naturally occurring fibrous form... [Pg.113]

Mixed inhibitors may simultaneously affect both anodic and cathodic processes. A mixed inhibitor is usually more desirable because its effect is all-encompassing, covering corrosion resulting from chloride attack as well as that due to microcells on the metal surface. Mixed inhibitors contain molecules in which electron density distribution causes the inhibitor to be attracted to both anodic and cathodic sites. They are aromatic or olefinic molecules with both proton-forming and electron acceptor functional group such as NH2 or SH, as in... [Pg.330]

Infrared Spectra. A Perkin-Elmer model 237 spectrometer was used. Solutions of 5 to 10 mg. per ml. of lipid in spectral grade chloroform were placed in a NaCl microcell of 1.0-mm. path length for study in the region from 2.5 to 6.0 microns. The film technique was used for observations between 5 and 15 microns, with a beam condenser and attenuator (Perkin-Elmer, Norwalk, Conn.). The lipid, 75 to 100 /i.grams in either chloroform or chloroform-methanol 85 to 15, was deposited on 1 sq. cm. of the NaCl plate, and the solvent was removed by evaporation under an infrared lamp for 10 minutes. [Pg.166]

Pulse polarographic studies have been described using a microcell of 0.5 mL capacity, which analyzed two 1,4-benzodiazepines, with the lowest detection limit reported to date being 10-20 ng/mL of blood [199]. Detailed construction of the cell and electrode assembly was also described (shown in Fig. 26.16). Further miniaturization of this type of three-electrode cell is not practical hence further increases in sensitivity will have to rely on electrochemical detector flow cells of microliter capacity such as those used in conjunction with liquid chromatography (see Chap. 27). [Pg.804]

Figure 26.16 Schematic diagram of the 0.5-mL-capacity microcell for pulse polaro-graphic studies. [From Ref. 199, reprinted with permission.]... Figure 26.16 Schematic diagram of the 0.5-mL-capacity microcell for pulse polaro-graphic studies. [From Ref. 199, reprinted with permission.]...
Figure 7.3.1.9 Relative sample volumes required for an assortment of NMR probes (a) conventional 5-mm tubes (b) 3-mm tubes with microcells (c) Varian Nano NMR (d) 1.7-mm tubes with minimal solvent (e) microcoil with a Fobs 30 nl... Figure 7.3.1.9 Relative sample volumes required for an assortment of NMR probes (a) conventional 5-mm tubes (b) 3-mm tubes with microcells (c) Varian Nano NMR (d) 1.7-mm tubes with minimal solvent (e) microcoil with a Fobs 30 nl...
Cell Parylene Figure 8.25. Schematic of a microcell lysis device. [Pg.373]

Kozak, C.A., R.E.K. Fournier, L.A. Leinwald, and F.H. Ruddle. Assignment of the gene governing cellular ouabain resistance to Mus musculus chromosome 3 using human/mouse microcell hybrids. Biochem. Genetics 17 23-34, 1979. [Pg.270]

Microcells. Cells that employ thin layers of solution (thin-layer electrodes) have special virtures that have been detailed in Chapter 5. In addition, the dipping thin-layer cell is especially useful for the measurement of chronopo-tentiometric n values.61 It is constructed from the components of a micrometer such that the cell thickness can be varied to permit a plot of the transition time versus solution thickness. This allows the determination of n, the number of electrons involved in the electrochemical reaction. An accuracy of 4% has been demonstrated for a number of compounds in different organic solvents. [Pg.282]

In most electrochemical measurements solutions are made up to an arbitrary volume that usually is at least 1 cm3. However a few microcells have been described for work with solution volumes that are well below 1 cm3. The coulometric determination of silver ion in cell volumes as small as 20 /iL (formed by a thin copper sheet and a cavity of beeswax) has been discussed.62... [Pg.282]


See other pages where Microcell is mentioned: [Pg.1440]    [Pg.1643]    [Pg.456]    [Pg.177]    [Pg.102]    [Pg.209]    [Pg.365]    [Pg.121]    [Pg.91]    [Pg.152]    [Pg.377]    [Pg.274]    [Pg.467]    [Pg.630]    [Pg.630]    [Pg.87]    [Pg.641]    [Pg.116]    [Pg.270]    [Pg.103]    [Pg.496]    [Pg.60]    [Pg.275]    [Pg.799]    [Pg.134]    [Pg.103]    [Pg.222]    [Pg.377]    [Pg.408]    [Pg.304]   
See also in sourсe #XX -- [ Pg.202 , Pg.204 , Pg.211 , Pg.212 ]

See also in sourсe #XX -- [ Pg.176 ]




SEARCH



Electrochemical microcell

Foamed microcells

MICROCELL TECHNOLOGY

Microcel

Microcel

Microcell corrosion

Microcell designs

Microcells

Microcells