Methylated, liquid chromatography

The separation of mixtures involving N-methyl-JLtetrahydropyridines into their pure components by means of gas-liquid chromatography was discussed in a report by Holik et al. (87). They found that, using tris(/3-cyanoethoxymethyl)-y-picoline as the stationary phase, the primary factors involved in the specific retention volumes of these enamines is the electronic effect of a methyl substituent and the nitrogen atom on the carbon-carbon double bond. It was observed that 1,3-dimethyl-Zl -tetrahydropyridine (141) has a smaller specific retention volume and, hence, is eluted before... [Pg.50]

Figure 12.22 SFC-GC analysis of aromatic fraction of a gasoline fuel, (a) SFC trace (b) GC ttace of the aromatic cut. SFC conditions four columns (4.6 mm i.d.) in series (silica, silver-loaded silica, cation-exchange silica, amino-silica) 50 °C 2850 psi CO2 mobile phase at 2.5 niL/min FID detection. GC conditions methyl silicone column (50 m X 0.2 mm i.d.) injector split ratio, 80 1 injector temperature, 250 °C earner gas helium temperature programmed, — 50 °C (8 min) to 320 °C at a rate of 5 °C/min FID detection. Reprinted from Journal of Liquid Chromatography, 5, P. A. Peaden and M. L. Lee, Supercritical fluid chromatography methods and principles , pp. 179-221, 1987, by courtesy of Marcel Dekker Inc. Figure 12.22 SFC-GC analysis of aromatic fraction of a gasoline fuel, (a) SFC trace (b) GC ttace of the aromatic cut. SFC conditions four columns (4.6 mm i.d.) in series (silica, silver-loaded silica, cation-exchange silica, amino-silica) 50 °C 2850 psi CO2 mobile phase at 2.5 niL/min FID detection. GC conditions methyl silicone column (50 m X 0.2 mm i.d.) injector split ratio, 80 1 injector temperature, 250 °C earner gas helium temperature programmed, — 50 °C (8 min) to 320 °C at a rate of 5 °C/min FID detection. Reprinted from Journal of Liquid Chromatography, 5, P. A. Peaden and M. L. Lee, Supercritical fluid chromatography methods and principles , pp. 179-221, 1987, by courtesy of Marcel Dekker Inc.
In a study of the metabolism of methyl parathion in intact and subcellular fractions of isolated rat hepatocytes, a high performance liquid chromatography (HPLC) method has been developed that separates and quantitates methyl parathion and six of its hepatic biotransformation products (Anderson et al. 1992). The six biotransformation products identified are methyl paraoxon, desmethyl parathion, desmethyl paraoxon, 4-nitrophenol, />nitrophenyl glucuronide, and /wiitrophenyl sulfate. This method is not an EPA or other standardized method, and thus it has not been included in Table 7-1. [Pg.178]

Abe T, Fujimoto Y, Tatsuno T, et al. 1979. Separation of methyl parathion and fenitrothion metabolites by liquid chromatography. Bull Environ Contam Toxicol 22 791-795. [Pg.191]

Clark GJ, Goodin RR, Smiley JW. 1985. Comparison of ultraviolet and reductive amperometric detection for determination of ethyl and methyl parathion in green vegetables and surface water using high-performance liquid chromatography. Anal Chem 57 2223-2228. [Pg.199]

De Schryver E, De Reu L, Willems JL. 1985. Determination of methyl paraoxon in dog plasma by reversed-phased high performance liquid chromatography. J Chromatogr 338 389-395. [Pg.201]

Jaglan PS, Gunther FA. 1970. Single column gas liquid chromatography of methyl parathion and metabolites using temperature programming. Bull Environ Contam Toxicol 5 111-114. [Pg.214]

Koen JG, Huber JF. 1970. A rapid method for residue analysis by column liquid chromatography with polarographic detection Application to the determination of parathion and methyl parathion on crops. Anal Chim Acta 51 303-307. [Pg.216]

The concentration of biodiesel (fetty acid methyl esters) and glycerides were analyzed by liquid chromatography (Shimadzu-lOA HPLC). An ODS-2 column (250x4.6mm) was used for the separation. The flow rate of the mobile phase (acetone acetonitrile=l l) was set to 1 ml/min. Peaks were identified by comparison with reference standards. Standards of methyl esters, monoglycerides, digjycerides and triglycerides were bought from Fluka. [Pg.154]

D2O = deutered water. HPLC = high performance liquid chromatography. IS = internal standard. MeOH = methanol. MS = mass spectrometry. NMR = nuclear magnetic resonance. PDA = photodiode array detector. TEA = triethylamine. MTBE = methyl tert-butyl ether. [Pg.461]

Bispyribac in water samples can be directly quantifled by high-performance liquid chromatography (HPLC) using an ultravilot (UV) detector without methylation. [Pg.474]

High-performance liquid chromatography (HPLC) with a micellar mobile phase or with a selective pre-column or reaction detection system has also been used to determine alkylenebis(dithiocarbamaes). ° Zineb and mancozeb residues in feed were determined by ion-pair HPLC with ultraviolet (UV) detection at 272 nm. These compounds were converted to water-soluble sodium salts with ethylenediaminetetra-acetic acid (EDTA) and sodium hydroxide. The extracts were ion-pair methylated with tetrabuthylammonium hydrogensulfate (ion-pair reagent) in a chloroform-hexane solvent mixture at pH 6.5-8.S. The use of an electrochemical detector has also been reported. ... [Pg.1091]

Figure 8.43 Separation of enantiomers using complexation chromatography. A, Separation of alkyloxiranes on a 42 m x 0.2S mm I.O. open tubular column coated with 0.06 M Mn(II) bis-3-(pentafluoro-propionyl)-IR-camphorate in OV-ioi at 40 C. B, Separation of D,L-amino acids by reversed-phase liquid chromatography using a mobile phase containing 0.005 M L-histidine methyl ester and 0.0025 M copper sulfate in an ammonium acetate buffer at pH 5.5. A stepwise gradient using increasing amounts of acetonitrile was used for this separation. Figure 8.43 Separation of enantiomers using complexation chromatography. A, Separation of alkyloxiranes on a 42 m x 0.2S mm I.O. open tubular column coated with 0.06 M Mn(II) bis-3-(pentafluoro-propionyl)-IR-camphorate in OV-ioi at 40 C. B, Separation of D,L-amino acids by reversed-phase liquid chromatography using a mobile phase containing 0.005 M L-histidine methyl ester and 0.0025 M copper sulfate in an ammonium acetate buffer at pH 5.5. A stepwise gradient using increasing amounts of acetonitrile was used for this separation.
Baillet, A., Corbeau, L., Rafidson, R, and Ferrier, D., Separation of isomeric compounds by reversed-phase high-performance liquid chromatography using Ag+ complexation. Application to cis-trans fatty acid methyl esters and retinoic acid photoisomers, /. Chromatogr., 634, 251, 1993. [Pg.51]

Figure 1 Electrochemical detection of catechol, acetaminophen, and 4-methyl catechol, demonstrating the selectivity of differential pulse detection vs. constant potential detection. (A) Catechol, (B) acetaminophen, and (C) 4-methylcatechol were separated by reversed phase liquid chromatography and detected by amperometry on a carbon fiber electrode. In the upper trace, a constant potential of +0.6 V was used. In the lower trace, a base potential of +425 mV and a pulse amplitude of +50 mV were used. An Ag/AgCl reference electrode was employed. Note that acetaminophen responds much more strongly than catechol or 4-methylcatechol under the differential pulse conditions, allowing highly selective detection. (Reproduced with permission from St. Claire, III, R. L. and Jorgenson, J. W., J. Chromatogr. Sci. 23, 186, 1985. Preston Publications, A Division of Preston Industries, Inc.)... Figure 1 Electrochemical detection of catechol, acetaminophen, and 4-methyl catechol, demonstrating the selectivity of differential pulse detection vs. constant potential detection. (A) Catechol, (B) acetaminophen, and (C) 4-methylcatechol were separated by reversed phase liquid chromatography and detected by amperometry on a carbon fiber electrode. In the upper trace, a constant potential of +0.6 V was used. In the lower trace, a base potential of +425 mV and a pulse amplitude of +50 mV were used. An Ag/AgCl reference electrode was employed. Note that acetaminophen responds much more strongly than catechol or 4-methylcatechol under the differential pulse conditions, allowing highly selective detection. (Reproduced with permission from St. Claire, III, R. L. and Jorgenson, J. W., J. Chromatogr. Sci. 23, 186, 1985. Preston Publications, A Division of Preston Industries, Inc.)...
The extracted fractions were esterified with either BF3-MeOH reagent or diazomethane and analyzed by GLC. Gas liquid chromatography (GLC) was conducted with a Perkin-Elmer Sigma 3 equipped with flame ionization detector. Separations were obtained on a Hewlett Packard 12 m x 0.2 mm i.d. capillary column coated with methyl silicon fluid (OV-101). The temperature was maintained at 80°C for 2 min then programmed from 80 to 220°C at 8°C/min. The injector temperature was 250°C. Mass spectra were obtained on a Hewlett Packard model 5995 GC-MS mass spectrometer, equipped with a 15 m fused silica capillary column coated with 5% phenyl methyl silicone fluid. Spectra were obtained for major peaks in the sample and compared with a library of spectra of authentic compounds. [Pg.103]

Engel, R. (1988) Determination of Thiophanate-methyl by High Performance Liquid Chromatography and UV Detection, Report BT-41, Medical Biological Laboratory TNO, Department of Occupational Toxicology, Rijswijk, The Netherlands (in Dutch). [Pg.137]

Analysis Techniques. The contents of the major breakdown products of xetralin (naphthalene and 1-methyl indan) present in the distillate were determined by gas-liquid chromatography using a Hewlett Packard Series 5750 Research Chromatograph with a 62m x 0.5mm diameter glass capillary SCOT column coated with nonpolar SE 30 liquid phase (see Reference (4 ) for details). [Pg.245]

The presence of hydrophenanthrene isomers was indicated by the observation of numerous GLC peaks with identical parent ions but different fragment ions in their mass spectra. Compounds with methyl substituents always have more intense M -15 ions than those with unsubstituted six-membered rings. Considering the complexity of the total reaction mixtures, liquid chromatography (HPLC) was used to concentrate more discrete solvent fractions for C-NMR study. [Pg.371]

Okamoto et al [85] performed the optical resolution of primaquine and other racemic drugs by high performance liquid chromatography using cellulose and amylose tris-(phenylcarbamate) derivatives as chiral stationary phases. Primaquine and other compounds were effectively resolved by cellulose and/or amylose derivatives having substituents such as methyl, tertiary butyl, or halogen, on the phenyl groups. [Pg.190]


See other pages where Methylated, liquid chromatography is mentioned: [Pg.33]    [Pg.656]    [Pg.185]    [Pg.1029]    [Pg.1030]    [Pg.237]    [Pg.287]    [Pg.562]    [Pg.102]    [Pg.550]    [Pg.984]    [Pg.256]    [Pg.58]    [Pg.287]    [Pg.49]    [Pg.533]    [Pg.1192]    [Pg.751]    [Pg.855]    [Pg.199]    [Pg.431]    [Pg.322]    [Pg.448]    [Pg.121]    [Pg.90]    [Pg.188]    [Pg.123]   