Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mechanical response methods

Applications of Muldconfigurational Self-consistent Field Classical Mechanics Response Method and Conclusion... [Pg.554]

In the following we give a short summary of the applications of multiconfigurational self-consistent field classical mechanics response method based on the work by Poulsen and co-workers [15-17], The investigated QM/CM system is represented as a sample of 128 H20 molecules, one of which is selected as the quantum mechanical subsystem while the remaining 127 H20 molecules represent the classical subsystem. [Pg.554]

In this section we outline the coupled cluster-molecular mechanics response method, the CC/MM response method. Ref. [51] considers CC response functions for molecular systems in vacuum and for further details we refer to this article. The identification of response functions is closely connected to time-dependent perturbation theory [51,65,66,67,68,69,70], Our starting point is the quasienergy and we identify the response functions as simple derivatives of the quasienergy. For a molecular system in vacuum where Hqm is the vacuum Hamiltonian for the unperturbed molecule and V" is a time-dependent perturbation we have the following time-dependent Hamiltonian, H,... [Pg.367]

MULTICONFIGURATIONAL SELF-CONSISTENT FIELD-MOLECULAR MECHANICS RESPONSE METHODS... [Pg.283]

Keywords Multiconfigurational self-consistent field molecular mechanics response methods,... [Pg.283]

Analytical separations may be classified in three ways by the physical state of the mobile phase and stationary phase by the method of contact between the mobile phase and stationary phase or by the chemical or physical mechanism responsible for separating the sample s constituents. The mobile phase is usually a liquid or a gas, and the stationary phase, when present, is a solid or a liquid film coated on a solid surface. Chromatographic techniques are often named by listing the type of mobile phase, followed by the type of stationary phase. Thus, in gas-liquid chromatography the mobile phase is a gas and the stationary phase is a liquid. If only one phase is indicated, as in gas chromatography, it is assumed to be the mobile phase. [Pg.546]

Noncrystalline domains in fibers are not stmctureless, but the stmctural organization of the polymer chains or chain segments is difficult to evaluate, just as it is difficult to evaluate the stmcture of Hquids. No direct methods are available, but various combinations of physicochemical methods such as x-ray diffraction, birefringence, density, mechanical response, and thermal behavior, have been used to deduce physical quantities that can be used to describe the stmcture of the noncrystalline domains. Among these quantities are the amorphous orientation function and the amorphous density, which can be related to some of the important physical properties of fibers. [Pg.272]

Whereas multi-wall carbon nanotubes require no catalyst for their growth, either by the laser vaporization or carbon arc methods, catalyst species are necessary for the growth of the single-wall nanotubes [156], while two different catalyst species seem to be needed to efficiently synthesize arrays of single wall carbon nanotubes by either the laser vaporization or arc methods. The detailed mechanisms responsible for the growth of carbon nanotubes are not yet well understood. Variations in the most probable diameter and the width of the diameter distribution is sensitively controlled by the composition of the catalyst, the growth temperature and other growth conditions. [Pg.66]

Along with, and closely connected to, the developments in precise impact techniques is the development of methods to carry out time-resolved materials response measurements of stress or particle velocity wave profiles. With time resolutions approaching 1 ns, these devices have enabled study of mechanical responses not possible in the early period of the 1960s. The improved time-resolutions have resulted from direct measurement of stress or particle velocity, rather than from improved accuracy and resolution in measurement of position and time. In a continuation of this trend, capabilities are being developed to provide direct measurements of the rate-of-change of stress. With the ability to measure such a derivative function, detailed study of new phenomena and improved resolution and accuracy in descriptions of known rate-dependent phenomena seem possible. [Pg.62]

This second group of tests is designed to measure the mechanical response of a substance to applied vibrational loads or strains. Both temperature and frequency can be varied, and thus contribute to the information that these tests can provide. There are a number of such tests, of which the major ones are probably the torsion pendulum and dynamic mechanical thermal analysis (DMTA). The underlying principles of these dynamic tests have been covered earlier. Such tests are used as relatively rapid methods of characterisation and evaluation of viscoelastic polymers, including the measurement of T, the study of the curing characteristics of thermosets, and the study of polymer blends and their compatibility. They can be used in essentially non-destructive modes and, unlike the majority of measurements made in non-dynamic tests, they yield data on continuous properties of polymeric materials, rather than discontinuous ones, as are any of the types of strength which are measured routinely. [Pg.116]

This paper summarizes the results of our study of PE and APE waveguides in LiNb03 and EiTa03. We foeused on the optical and structural characterization of PE layers formed on Z-eut substrates. The reffaetive index ehange was measured and the propagation losses were estimated. Raman speetroseopy was used as a method providing direct information about the phonon spectrum. The latter was related to the structure and ehemieal bonds of a given erystalline phase. Sueh information may be useful for eorreet identification of both phase eomposition and the microscopic mechanisms responsible for the observed variation of the properties from phase to phase. [Pg.230]

The stationary phase may be a solid or liquid on a solid support. The mechanisms responsible for distribution between phases include surface absorption, ion exchange, relative solubilities and steric affects . High performance liquid chromatography is a useful method for quinolizidine alkaloid analysis, especially when pure standards are available". This method was recently used for alkaloid metabolite extraction and analysis . A simple reversed-phase liquid chromatographic method has been developed for the simultaneous quantitation of four anticancerous alkaloids vincristine, vinblastine, and their precursors catharanthine and vindoline using a specific HPLC column . [Pg.133]

The methodology presented is generic and can be applied to other types of materials, laminate constructions, and processing methods. In all cases a characterization of the cure state is needed first. As a result, models must be developed to predict the mechanical response as a function of the cure state. Mechanics models can then be developed for the specific application of interest. [Pg.268]

By combining the results of several methods (dynamic mechanical, dielectric, NMR, etc.), it is usually possible to determine quite reliably the structural units whose motions give rise to secondary relaxations. If dynamic mechanical measurements alone are employed, the usual procedure is that the chemical constitution is systematically altered and correlated with the dynamic mechanical response spectra, i.e. with the temperature-dependence of the G" and G moduli. If the presence of a certain group in polymers is marked by the formation of a loss peak characterized by a certain temperature position, size and shape etc., then the conclusion may be drawn that the motional units responsible for the secondary relaxation are identical or related with that group. Naturally, the relations obtained in this way are empirical and qualitative. [Pg.130]

That heat is not the only method to unmask epitopes is exemplified by enzyme digestion or detergent treatment. The exact mechanism responsible for epitope retrieval with ultrasound is not clear, although intense heat is produced for an exceedingly short duration. It is known, however, that ultrasound and/or heat decreases the amount of negative charges on the cell surface (Joshi et al., 1983 Adler et al., 1988). Mechanical vibrations of molecules caused by ultrasound and heat are thought to unfold the protein molecule and to expose the epitopes. [Pg.118]

There are many potential mechanisms responsible for the occurrence of aspirin resistance or nonresponsiveness. Many of these studies reporting aspirin resistance have employed methods that did not isolate COX-1 inhibition and/or used treatment failure as their definition for aspirin resistance. Cigarette smoking, noncompliance, transient expression of COX-2 in newly formed platelets, and extra-platelet sources of PGG2/PGH2 (endothelial cells, monocytes/macrophages) may contribute to an attenuated clinical response to aspirin (63-66). Erythrocytes may attenuate the effect of aspirin by... [Pg.142]

A Models to describe microparticles with a core/shell structure. Diametrical compression has been used to measure the mechanical response of many biological materials. A particular application has been cells, which may be considered to have a core/shell structure. However, until recently testing did not fully integrate experimental results and appropriate numerical models. Initial attempts to extract elastic modulus data from compression testing were based on measuring the contact area between the surface and the cell, the applied force and the principal radii of curvature at the point of contact (Cole, 1932 Hiramoto, 1963). From this it was possible to obtain elastic modulus and surface tension data. The major difficulty with this method was obtaining accurate measurements of the contact area. [Pg.44]


See other pages where Mechanical response methods is mentioned: [Pg.601]    [Pg.263]    [Pg.1]    [Pg.187]    [Pg.194]    [Pg.15]    [Pg.119]    [Pg.134]    [Pg.559]    [Pg.522]    [Pg.367]    [Pg.298]    [Pg.88]    [Pg.194]    [Pg.300]    [Pg.374]    [Pg.347]    [Pg.256]    [Pg.1526]    [Pg.263]    [Pg.123]    [Pg.142]    [Pg.21]    [Pg.117]    [Pg.25]    [Pg.71]    [Pg.306]    [Pg.33]    [Pg.77]    [Pg.171]   
See also in sourсe #XX -- [ Pg.134 ]




SEARCH



Mechanical methods

Mechanical response

Response methods

© 2024 chempedia.info