Measurement methods chemiluminescence

Differences in measurement methods include analyzer systems based both on the same and on different measurement principles. The average standard deviation in the performance of different chemiluminescent ozone instruments that are sampling the same ambient air both with and without an added ozone concentration of 0.(X)2-0.5 ppm is 6-10%. Field studies comparing an ultraviolet monitor with several chemiluminescent monitors showed correlation coefficients for hourly averages of 0.80-0.95 between various pairs of instruments. Hourly averages for about 500 pairs of values at ambient ozone concentrations of 0.005-0.100 ppm showed deviations of 3-23% between the average values for paired instruments. [Pg.275]

Continuous Measurement Methods for Trace Cases and Aerosols. Ozone. Three basic types of ozone instruments have been used in aircraft the ultraviolet photometric method and two chemiluminescent techniques measuring, respectively, light emitted from the reaction of 03 with ethylene and light emitted from the reaction of 03 with NO. Ultraviolet absorption photometry is one of the preferred methods for measuring 03 from aircraft because of the stability and reliability of commercially available instruments. The method is specific for 03 provided there are no immediate... [Pg.130]

In the process of developing PRMs, it is necessary to study and establish measurement methods which are used to analyzed the purity of raw gases and verify the stability of the gas mixture kept in the cylinder. Up to now, NRCCRM has been equipped with several series of analytical techniques including atmospheric pressure ionization mass spectrometer, gas chromatograph, infra-red spectrophotometer with long-path gas cell, chemiluminescent, non-dispersive infra-red, minor 02 and H20 analyzer and so on. [Pg.273]

A9. Alho, H., and Leinonen, J., Total antioxidant activity measured by chemiluminescence methods. Meth. Enzyntol. 299, 3-14 (1999). [Pg.273]

Since the radioactive sample material from most methods of sample preparation is in intimate contact or in actual solution with the phosphor, the detection of emitted particles or radiation is highly efficient and may even approach 100%. Problems of self-absorption of the emissions are thus absent, or considerably smaller than those associated with planchette counting of solid samples. This is of particular importance for the measurement of low energy beta emitters such as tritium and carbon-14. On the other hand, the measurement method has intrinsic drawbacks such as quenching and chemiluminescence. [Pg.185]

The high correlation coefficient indicated that the measurement of chemiluminescence intensity provides a quantitative measurement of the toxicity of an analyte. Furthermore, the calculation of the partial charge change by the computational chemical method can be used to estimate the rat oral LD50. [Pg.398]

Selected scaled ks results have been presented in Table VII. A more extensive listing follows in Appendix B. Many thermal hydrogen abstraction and olefinic addition reactions have been tabulated that are too fast to be characterized using the available direct measurement methods. Based on comparisons with the scaled MNR data, the HF chemiluminescence (52), electron spin resonance (53,66), and laser pulse decay (54,67), absolute teclmiques apparently involve large systematic errors. [Pg.222]

The combination of e.p.r. spectrometry with the fixed observation point method (section 4.4.4) has permitted the extension of kinetic measurements of atom decay rates to elevated temperatures. The results of such studies on the reactions O + H2 OH + H and Cl + Ha -> HCl + H are in good agreement with measurements using chemiluminescence and titration. The rate constant for the recombination reaction H + H + M- Hg + M using e.p.r. spectrometry has also been reported. ... [Pg.264]

Reference methods for criteria (19) and hazardous (20) poUutants estabHshed by the US EPA include sulfur dioxide [7446-09-5] by the West-Gaeke method carbon monoxide [630-08-0] by nondispersive infrared analysis ozone [10028-15-6] and nitrogen dioxide [10102-44-0] by chemiluminescence (qv) and hydrocarbons by gas chromatography coupled with flame-ionization detection. Gas chromatography coupled with a suitable detector can also be used to measure ambient concentrations of vinyl chloride monomer [75-01-4], halogenated hydrocarbons and aromatics, and polyacrylonitrile [25014-41-9] (21-22) (see Chromatography Trace and residue analysis). [Pg.384]

Clinical Analysis. A wide range of clinically important substances can be detected and quantitated using chemiluminescence or bioluminescence methods. Coupled enzyme assay protocols permit the measurement of kinase, dehydrogenase, and oxidases or the substrates of these enzymes as exemplified by reactions of glucose, creatine phosphate, and bile acid in the following ... [Pg.275]

Luminol chemiluminescence has also been recommended for measuring bacteria populations (304,305). The luminol—hydrogen peroxide reaction is catalyzed by the iron porphyrins contained in bacteria, and the light intensity is proportional to the bacterial concentration. The method is rapid, especially compared to the two-day period required by the microbiological plate-count method, and it correlates weU with the latter when used to determine bacteria... [Pg.275]

Ozone can be analyzed by titrimetry, direct and colorimetric spectrometry, amperometry, oxidation—reduction potential (ORP), chemiluminescence, calorimetry, thermal conductivity, and isothermal pressure change on decomposition. The last three methods ate not frequently employed. Proper measurement of ozone in water requites an awareness of its reactivity, instabiUty, volatility, and the potential effect of interfering substances. To eliminate interferences, ozone sometimes is sparged out of solution by using an inert gas for analysis in the gas phase or on reabsorption in a clean solution. Historically, the most common analytical procedure has been the iodometric method in which gaseous ozone is absorbed by aqueous KI. [Pg.503]

The biological and medical sciences are ripe for iastmmentation advances. Whereas most immunoassays (qv) use radioactive materials, the implementation of chemiluminescent methods, enzyme techniques, and electrochemical methods is expected to become more important. New and better noninvasive methods of iavestigation are expected to become more routine. In addition, real-time measurements, whereby analyses of a number of... [Pg.397]

A method of detecting herbicides is proposed the photosynthetic herbicides act by binding to Photosystem II (PS II), a multiunit chlorophyll-protein complex which plays a vital role in photosynthesis. The inhibition of PS II causes a reduced photoinduced production of hydrogen peroxide, which can be measured by a chemiluminescence reaction with luminol and the enzyme horseradish peroxidase (HRP). The sensing device proposed combines the production and detection of hydrogen peroxide in a single flow assay by combining all the individual steps in a compact, portable device that utilises micro-fluidic components. [Pg.332]

The principal method used for measuring NO2 is also based on chemiluminescence (Fig. 14-3) (5). NO2 concentrations are determined indirectly from the difference between the NO and NO (NO -I- NO2) concentrations in the atmosphere. These concentrations are determined by measuring the tight emitted from the chemiluminescent reaction of NO with 03 (similar to the reaction of O3 with ethylene noted for the measurement of O3), except that O3 is supplied at a high constant concentration, and the light output is proportional to the concentration of NO present in the ambient air stream. [Pg.199]

Describe the potential interferences (a) in the nondispersive infrared (NDIR) method for measuring CO and (b) in the chemiluminescent method for measuring NO2. [Pg.214]

A note on the assays of coelenterazine and luciferase activity. The methods for measuring coelenterazine and the corresponding luciferases are given in Appendix C5. Special attention must be paid to the fact that coelenterazine in aqueous buffer solutions spontaneously emits a low level of chemiluminescence in the absence of any luciferase, which is greatly enhanced by the presence of various substances, including egg yolk, BSA and various surfactants (especially, hexadecyltrimethylammonium bromide). Therefore, the utmost care must be taken in the detection and measurement of a low level of... [Pg.164]


See other pages where Measurement methods chemiluminescence is mentioned: [Pg.276]    [Pg.1104]    [Pg.569]    [Pg.582]    [Pg.847]    [Pg.434]    [Pg.853]    [Pg.48]    [Pg.389]    [Pg.404]    [Pg.326]    [Pg.92]    [Pg.117]    [Pg.873]    [Pg.264]    [Pg.275]    [Pg.276]    [Pg.276]    [Pg.395]    [Pg.395]    [Pg.157]    [Pg.197]    [Pg.494]    [Pg.58]    [Pg.361]    [Pg.1]    [Pg.154]    [Pg.954]    [Pg.301]    [Pg.599]    [Pg.742]    [Pg.15]    [Pg.452]   