Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Matrix referencing

The quantity of the hterature in the field of the nanocomposite polymeric materials has grown multiple times in recent years. The possibility to use almost all polymeric and polycondensated materials as a matrix is shown The nanocomposites from various organoclays and polymers have been synthesized. Here is just a small part of the compounds for being the matrix referenced in literature polyacrylate [83], polyamides [82,84,85], polybenzoxazine [86], polybutylene terephtalate [11,82,87], polyimides [88], polycarbonate [89], polymethylmetaciylate [90], polypropylene [91,92], poly-... [Pg.64]

At the time the experimental work referred to at the beginning of this series of examples [50] was undertaken, there was a belief that matrix referencing should remove the effect of the matrix and isolate the absorption of the analyte. The experimental data (reported in previous editions of this Handbook) showed unambiguously that, whether using/(Roo) or log(l/Roo) as the metric, the matrix referencing technique would not work in the way envisioned. However, when the experimental work was done, there was not a theory available that would predict the results that were obtained. [Pg.52]

A matrix referencing scheme in which a unique reference is made for each sample (marked Unique in Figure 3.8). These reference materials are assumed to have the same contribution of matrix absorption in the reference (uniquely made for this sample) as in the sample. Thus if the absorption fraction for a matrix layer is 0.05 (5%), and the particle fraction of the matrix is 0.5 (50%), then the contribution of the reference material to the absorption fraction of a single layer of the sample would be (0.05 x 0.5 = 0.025) or 2.5%. [Pg.53]

To subtract the matrix absorption successfully, two criteria must be fulfilled (a) the reference must match the absorption of the matrix and (b) the remission from the reference must remain constant at all concentrations. In this matrix-referencing scheme, we have assured that we have matched the absorption of the matrix and kept the remission/or a single layer constant at all concentrations. The remission of the reference will vary with concentration because the effective pathlength changes with absorption. [Pg.54]

From the preceding example, it can be seen that the representative layer theory predicts that the unique matrix referencing technique would not work. In this example, we will show that the shape of the experimental curves is predicted by the representative layer theory. In this study, log(l//i) and K-M matrix referenced data were obtained from three series of infinitely thick samples ... [Pg.54]

FIGURES.9 A unique matrix referencing scheme can yield a linear K-M plot only with a nonabsorbing matrix and when plotted against a volume based measure of concentration. The log(l/i oo) curves are in general not linear. From top to bottom, the lines in each chart represent 0, 1, and 5% absorption by matrix particles. The lines represent values calculated by the representative layer theory. (Reproduced from D. J. Dahm, NIR News, 15 6-10 (2007), by permission of NIR Publications Copyright 2007.)... [Pg.55]

Matrix referencing will cause a nonlinearity for both metrics (if the matrix has absorption). [Pg.61]

The determination of absolute reflectance is more important when using the K-M function as the metric for absorption than for log(l/R) data. If we define (/s//r) as the relative reflectance R, then log(l/R ) = log(/R//s) = log(/jj) - log(/s). The reference value log(/tef) is a constant offset at a particular wavelength. Furthermore, if the reference is the matrix in which the analyte is embedded, the measurement becomes a direct measure of the absorption of the analyte. However, the K-M function using relative reflectance is not linearly related to the K-M function using absolute reflectance, as shown in the examples in Section 3.6. Matrix referencing with the K-M function would require measuring the function for the matrix and the sample, each on an absolute scale and subtracting. [Pg.61]

Molecules with rings should always be given a dummy atom in the center of the ring. The atoms in the ring should then be referenced to the central dummy atom rather than each other. Here is a Z-matrix for a benzene molecule enforcing Dfih symmetry ... [Pg.75]

Pd removal was determined as follows. An aliquot of a representative liquid or solid sample was accurately weighed and subsequently digested by refluxing in nitric and/or hydrochloric acid using a closed vessel microwave procedure (CEM MARS5 Xpress or Milestone Ethos EZ). Cooled, digested samples were diluted, matrix matched to standards, and referenced to a linear calibration curve for quantitation an internal standard was employed to improve quantitation. All samples were analyzed by an Inductively Coupled Plasma Mass Spectrometer or ICP/MS (Perkin Elmer SCIEX Elan DRCII) operated in the standard mode. [Pg.54]

To solve the set of linear equations introduced in our previous chapter referenced as [1], we will now use elementary matrix operations. These matrix operations have a set of rules which parallel the rules used for elementary algebraic operations used for solving systems of linear equations. The rules for elementary matrix operations are as follows [2] ... [Pg.17]

A number of promising C02 sensors have been described13,33. The phase-fluorometric system employing dual luminophore referencing, which is rather complex (two dyes, internal buffer system, sol-gel polymer matrix), has demonstrated satisfactory working characteristics33. But it still has to prove its safety and cost-effectiveness, and requires extensive validation with real food samples. [Pg.511]

The individual elements of a matrix are often referenced as scalars, with subscripts referring to the row and column hence, in the matrix above, y2i = 6 which is the element in row 2 and column 1. [Pg.27]

CpWIr3(CO)n was prepared as previously described (2). Diphenylacetylene (Aldrich) was used as received. Preparative thin-layer chromatography was carried out on (20 x 20 cm) silica gel Si250F plates (J.T. Baker). Infrared spectra were recorded on a Perkin-Elmer 1750 FT-IR spectrophotometer. H NMR (360 MHz) spectra were obtained on a Nicolet NT-360 spectrometer. Fast atom bombardment (FAB) mass spectra were obtained by the staff of the Mass Spectrometry Laboratory of the School of Chemical Sciences on a VG ZAB-SE mass spectrometer, using a matrix of dithioerythritol/dithiothieitol calculated masses are referenced to 184W and 193Ir. Elemental analyses were performed by the School Microanalytical Laboratory. [Pg.131]


See other pages where Matrix referencing is mentioned: [Pg.28]    [Pg.21]    [Pg.53]    [Pg.54]    [Pg.54]    [Pg.61]    [Pg.62]    [Pg.392]    [Pg.395]    [Pg.395]    [Pg.396]    [Pg.397]    [Pg.28]    [Pg.21]    [Pg.53]    [Pg.54]    [Pg.54]    [Pg.61]    [Pg.62]    [Pg.392]    [Pg.395]    [Pg.395]    [Pg.396]    [Pg.397]    [Pg.61]    [Pg.13]    [Pg.101]    [Pg.32]    [Pg.22]    [Pg.95]    [Pg.147]    [Pg.11]    [Pg.4]    [Pg.76]    [Pg.402]    [Pg.427]    [Pg.465]    [Pg.25]    [Pg.17]    [Pg.304]    [Pg.65]    [Pg.241]    [Pg.240]    [Pg.594]   
See also in sourсe #XX -- [ Pg.52 , Pg.55 , Pg.61 ]




SEARCH



Referencing

© 2024 chempedia.info