Mass spectrometry sample inlets

Beckmann, K., Messinger, J., Badger, M.R., Wydrzynski, T., Hillier, W. On-line mass spectrometry membrane inlet sampling. Photosynth. Res. 102, 511-522 (2009)... [Pg.429]

The advent of atmospheric-pressure ionization (API) provided a method of ionizing labile and nonvolatile substances so that they could be examined by mass spectrometry. API has become strongly linked to HPLC as a basis for ionizing the eluant on its way into the mass spectrometer, although it is also used as a stand-alone inlet for introduction of samples. API is important in thermospray, plasmaspray, and electrospray ionization (see Chapters 8 and 11). [Pg.61]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

Few of the naturally occurring elements have significant amounts of radioactive isotopes, but there are many artificially produced radioactive species. Mass spectrometry can measure both radioactive and nonradioactive isotope ratios, but there are health and safety issues for the radioactive ones. However, modem isotope instmments are becoming so sensitive that only very small amounts of sample are needed. Where radioactive isotopes are a serious issue, the radioactive hazards can be minimized by using special inlet systems and ion pumps in place of rotary pumps for maintaining a vacuum. For example, mass spectrometry is now used in the analysis of Pu/ Pu ratios. [Pg.354]

Mass Spectrometry. The mass spectra were obtained on a CEC 21-llOB mass spectrometer with the batch inlet system maintained at 250°C to assure complete vaporization of the samples. Sensitivity factors for quantitative analysis were obtained from standards of di-, tetra-, hexa-, and octa-chlorodibenzo-p-dioxin. The factors for the intermediate chlorinated species were estimated by interpolation. The analyses were based... [Pg.5]

For non-volatile sample molecules, other ionisation methods must be used, namely desorption/ionisation (DI) and nebulisation ionisation methods. In DI, the unifying aspect is the rapid addition of energy into a condensed-phase sample, with subsequent generation and release of ions into the mass analyser. In El and Cl, the processes of volatilisation and ionisation are distinct and separable in DI, they are intimately associated. In nebulisation ionisation, such as ESP or TSP, an aerosol spray is used at some stage to separate sample molecules and/or ions from the solvent liquid that carries them into the source of the mass spectrometer. Less volatile but thermally stable compounds can be thermally vaporised in the direct inlet probe (DIP) situated close to the ionising molecular beam. This DIP is standard equipment on most instruments an El spectrum results. Techniques that extend the utility of mass spectrometry to the least volatile and more labile organic molecules include FD, EHD, surface ionisation (SIMS, FAB) and matrix-assisted laser desorption (MALD) as the last... [Pg.359]

Also, direct determination of additives by means of laser desorption in solid polymeric materials rather than in polymer extracts has been reported [266], Takayama et al. [267] have described the direct detection of additives on the surface of LLDPE/(Chimassorb 944 LD and Irgafos P-EPQ) after matrix (THAP)-coating. As shown in Scheme 7.13, direct inlet mass spectrometry is also applicable to transfer TLC-MS and TLC-MS/MS analyses without the need for prior analysis. For direct sample introduction a small amount of the selected... [Pg.413]

In addition to GC/MS, high performance liquid chromatography (HPLC/MS) has been used to analyse natural resins in ancient samples, particularly for paint varnishes containing mastic and dammar resins [34]. A partial limitation of chromatographic techniques is that they do not permit the analysis of the polymeric fraction or insoluble fraction that may be present in the native resins or formed in the course of ageing. Techniques based on the direct introduction of the sample in the mass spectrometer such as direct temperature resolved mass spectrometry (DTMS), direct exposure mass spectrometry (DE-MS) and direct inlet mass spectrometry (DI-MS), and on analytical pyrolysis (Py-GC/MS), have been employed as complementary techniques to obtain preliminary information on the... [Pg.217]

Caldecourt, V.J. Heated Sample Inlet System for Mass Spectrometry. Anal. Chem. 1955, 27, 1670. [Pg.221]

Mass spectrometry is a sensitive analytical technique which is able to quantify known analytes and to identify unknown molecules at the picomoles or femto-moles level. A fundamental requirement is that atoms or molecules are ionized and analyzed as gas phase ions which are characterized by their mass (m) and charge (z). A mass spectrometer is an instrument which measures precisely the abundance of molecules which have been converted to ions. In a mass spectrum m/z is used as the dimensionless quantity that is an independent variable. There is still some ambiguity how the x-axis of the mass spectrum should be defined. Mass to charge ratio should not lo longer be used because the quantity measured is not the quotient of the ion s mass to its electric charge. Also, the use of the Thomson unit (Th) is considered obsolete [15, 16]. Typically, a mass spectrometer is formed by the following components (i) a sample introduction device (direct probe inlet, liquid interface), (ii) a source to produce ions, (iii) one or several mass analyzers, (iv) a detector to measure the abundance of ions, (v) a computerized system for data treatment (Fig. 1.1). [Pg.4]

Mass spectrometry. Reaction of OH to form an ion, HS04, which can be measured by mass spectrometry was first demonstrated by Eisele and Tanner (1991). Figure 11.45 is a schematic diagram of this approach (Tanner et al., 1997). Air is sampled through an inlet system described in detail by Eisele et al. (1997) and mixed with isotopically labeled 34SOz, forming H24S04 via reactions discussed in Chapter 8.C.2 ... [Pg.601]

The metal balance for all the elements analyzed by mass spectrometry is good, but on the average shows a negative imbalance of 20%. Metals showing high imbalance, i.e., mercury, arsenic, and selenium, probably were in the gaseous state at the sample points. For example, a precipitator outlet sample of mercury showed a flow of 0.02 g min"1. At this sampling point the particulates are much cooler than the fly ash at the precipitator inlet. [Pg.90]


See other pages where Mass spectrometry sample inlets is mentioned: [Pg.1229]    [Pg.83]    [Pg.2]    [Pg.670]    [Pg.55]    [Pg.97]    [Pg.277]    [Pg.277]    [Pg.353]    [Pg.321]    [Pg.310]    [Pg.351]    [Pg.409]    [Pg.104]    [Pg.43]    [Pg.78]    [Pg.98]    [Pg.126]    [Pg.121]    [Pg.72]    [Pg.78]    [Pg.423]    [Pg.612]    [Pg.233]    [Pg.444]    [Pg.22]    [Pg.216]    [Pg.305]    [Pg.396]    [Pg.204]    [Pg.222]    [Pg.135]    [Pg.321]    [Pg.7]    [Pg.98]    [Pg.542]   