Mass spectrometry hyphenated techniques

Spectrometry Chemical Ionization in Mass Spectrometry Chemical Structure Information from Mass Spectrometry Forensic Science, Applications of Mass Spectrometry Hyphenated Techniques, Applications of in Mass Spectrometry Laser Microprobe Mass Spectrometers MS-MS and MS" Peptides and Proteins Studied Using Mass Spectrometry Quadru-poles. Use of in Mass Spectrometry. [Pg.755]

Spectrochemical methods Higher yield ion sources for mass spectrometry Hyphenated techniques, gas or liquid chromatogr hy with inductively coupled plasma emission spectroscopy Minimization of sample preparation... [Pg.39]

Silberring, J., Ekman, R., Desiderio, D.M., and Nibbering, N. M., Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, Wiley Interscience, New York, 2002. [Pg.451]

Multidimensional or hyphenated instmments employ two or more analytical instmmental techniques, either sequentially, or in parallel. Hence, one can have multidimensional separations, eg, hplc/gc, identifications, ms/ms, or separations/identifications, such as gc/ms (see CHROMATOGRAPHY Mass spectrometry). The purpose of interfacing two or more analytical instmments is to increase the analytical information while reducing data acquisition time. For example, in tandem-mass spectrometry (ms/ms) (17,18), the first mass spectrometer appHes soft ionization to separate the mixture of choice into molecular ions the second mass spectrometer obtains the mass spectmm of each ion. [Pg.394]

The possibiHties for multidimensional iastmmental techniques are endless, and many other candidate components for iaclusion as hyphenated methods are expected to surface as the technology of interfacing is resolved. In addition, ternary systems, such as gas chromatography-mass spectrometry-iafrared spectrometry (gc/ms/ir), are also commercially available. [Pg.395]

Coupling of analytical techniques (detectors) to high-performance liquid chromatographic (HPLC) systems has increased in the last tree decades. Initially, gas chromatography was coupled to mass spectrometry (MS), then to infrai ed (IR) spectroscopy. Following the main interest was to hyphenate analytical techniques to HPLC. [Pg.342]

The combination of chromatography and mass spectrometry (MS) is a subject that has attracted much interest over the last forty years or so. The combination of gas chromatography (GC) with mass spectrometry (GC-MS) was first reported in 1958 and made available commercially in 1967. Since then, it has become increasingly utilized and is probably the most widely used hyphenated or tandem technique, as such combinations are often known. The acceptance of GC-MS as a routine technique has in no small part been due to the fact that interfaces have been available for both packed and capillary columns which allow the vast majority of compounds amenable to separation by gas chromatography to be transferred efficiently to the mass spectrometer. Compounds amenable to analysis by GC need to be both volatile, at the temperatures used to achieve separation, and thermally stable, i.e. the same requirements needed to produce mass spectra from an analyte using either electron (El) or chemical ionization (Cl) (see Chapter 3). In simple terms, therefore, virtually all compounds that pass through a GC column can be ionized and the full analytical capabilities of the mass spectrometer utilized. [Pg.19]

In the case of the low abundance of some compounds, there are difficulties with signal overlap. To overcome these difficulties, there have been developments involving NMR hyphenation with techniques such as HPLC and mass spectrometry. In LC/NMR methods of analysis, NMR is used as the detector following LC separation and this technique is capable of detecting low concentrations in the nanogram range. This technique has been reported for the detection and identification of flavanoids in fruit juices and the characterization of sugars in wine [17]. [Pg.479]

In the deformulation of PE/additive systems by mass spectrometry, much less fragmentation was observed with DCI-MS/MS using ammonia as a reagent gas, than with FAB-MS [69]. FAB did not detect all the additives in the extracts. The softness and the lack of matrix effect make ammonia DCI a better ionisation technique than FAB for the analysis of additives directly from the extracts. Applications of hyphenated FAB-MS techniques are described elsewhere low-flow LC-MS (Section 7.3.3.2) and CE-MS (Section 7.3.6.1) for polar nonvolatile organics, and TLC-MS (Section 7.3.5.4). [Pg.371]

This chapter deals mainly with (multi)hyphenated techniques comprising wet sample preparation steps (e.g. SFE, SPE) and/or separation techniques (GC, SFC, HPLC, SEC, TLC, CE). Other hyphenated techniques involve thermal-spectroscopic and gas or heat extraction methods (TG, TD, HS, Py, LD, etc.). Also, spectroscopic couplings (e.g. LIBS-LIF) are of interest. Hyphenation of UV spectroscopy and mass spectrometry forms the family of laser mass-spectrometric (LAMS) methods, such as REMPI-ToFMS and MALDI-ToFMS. In REMPI-ToFMS the connecting element between UV spectroscopy and mass spectrometry is laser-induced REMPI ionisation. An intermediate state of the molecule of interest is selectively excited by absorption of a laser photon (the wavelength of a tuneable laser is set in resonance with the transition). The excited molecules are subsequently ionised by absorption of an additional laser photon. Therefore the ionisation selectivity is introduced by the resonance absorption of the first photon, i.e. by UV spectroscopy. However, conventional UV spectra of polyatomic molecules exhibit relatively broad and continuous spectral features, allowing only a medium selectivity. Supersonic jet cooling of the sample molecules (to 5-50 K) reduces the line width of their... [Pg.428]

Gas and liquid chromatography directly coupled with atomic spectrometry have been reviewed [178,179], as well as the determination of trace elements by chromatographic methods employing atomic plasma emission spectrometric detection [180]. Sutton et al. [181] have reviewed the use and applications of ICP-MS as a chromatographic and capillary electrophoretic detector, whereas Niessen [182] has briefly reviewed the applications of mass spectrometry to hyphenated techniques. [Pg.456]

Further developments of this topic are in progress, both in developing theoretical models and in applying the procedures to real experimental cases. In particular, the methods can be extended to hyphenated techniques to investigate the complex signals obtained from mass spectrometry detection (Pietrogrande et al., 2006b). [Pg.88]

Hyphenated techniques like combination of optical detection methods based on reflectometry or refractometry and separation techniques are of future interest. The same is valid for the intention to couple SPR or RIfS with mass spectrometry like MALDI33. [Pg.235]

The identification of GC peaks other than through retention data, which are sometimes ambiguous or inconclusive, can be facilitated by the direct interfacing of GC with infrared spectrometry (p. 378 et seq.) or mass spectrometry (p. 426 etseq.), so-called coupled or hyphenated techniques. The general instrumental arrangement is shown in Figure 4.29(a). [Pg.114]

Figure 2.6. Schematic of an electrospray ionization (ESI) source. Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With permission of John Wiley Sons, Inc. Figure 2.6. Schematic of an electrospray ionization (ESI) source. Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With permission of John Wiley Sons, Inc.
Figure 2.9. Schematic of a matrix-assisted laser desorption/ionization (MALDI) event. The SEM micrograph depicts sinapinic acid-equine myoglobin crystal from a sample prepared according to the dried drop sample preparation method. In the desorption event neutral matrix molecules (M), positive matrix ions (M+), negative matrix ions (M-), neutral analyte molecules (N), positive analyte ions (+), and negative analyte ions (-) are created and/or transferred to the gas phase. Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With permission of John Wiley Sons, Inc. Figure 2.9. Schematic of a matrix-assisted laser desorption/ionization (MALDI) event. The SEM micrograph depicts sinapinic acid-equine myoglobin crystal from a sample prepared according to the dried drop sample preparation method. In the desorption event neutral matrix molecules (M), positive matrix ions (M+), negative matrix ions (M-), neutral analyte molecules (N), positive analyte ions (+), and negative analyte ions (-) are created and/or transferred to the gas phase. Reprinted from A. Westman-Brinkmalm and G. Brinkmalm (2002). In Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research, J. Silberring and R. Ekman (eds.) New York John Wiley Sons, 47-105. With permission of John Wiley Sons, Inc.

See other pages where Mass spectrometry hyphenated techniques is mentioned: [Pg.42]    [Pg.1249]    [Pg.42]    [Pg.1249]    [Pg.504]    [Pg.410]    [Pg.396]    [Pg.390]    [Pg.420]    [Pg.201]    [Pg.395]    [Pg.243]    [Pg.106]    [Pg.81]    [Pg.105]    [Pg.4]    [Pg.480]    [Pg.287]    [Pg.21]    [Pg.427]    [Pg.455]    [Pg.496]    [Pg.62]    [Pg.52]    [Pg.215]    [Pg.135]    [Pg.42]    [Pg.43]    [Pg.47]   
See also in sourсe #XX -- [ Pg.56 ]