Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass spectrometry coupling with inductively coupled

Mass Spectrometry Combined with Inductively Coupled Plasma... [Pg.290]

Seubert, A. Schminke, G. Nowack, M. Ahter, W. Buchberger, W. Comparison of on-line couphng of ion-chromatography with atmosphere pressure ionisation mass spectrometry and with inductively coupled plasma mass spectrometry as tools for the ultra-trace analysis of bromate in surface water samples. J. Chromatogr. 2000,884, 191-196. EC contract SMT4-CT96-2134, EUR report, European Commission, No. 1960, ISBN 92-828-9401-0 Brussels. 2000. [Pg.1217]

Inoue Y, Kawabata K (1993) Speciation of organotin compounds by inductively coupled plasma mass spectrometry combined with liquid chromatography. Journal of the Mass Spectrometry Society of Japan, 41 (4) 245-251. [Pg.47]

Method abbreviations D-AT-FAAS (derivative flame AAS with atom trapping), ETAAS (electrothermal AAS), GC (gas chromatography), HGAAS (hydride generation AAS), HR-ICP-MS (high resolution inductively coupled plasma mass spectrometry), ICP-AES (inductively coupled plasma atomic emission spectrometry), ICP-MS (inductively coupled plasma mass spectrometry), TXRF (total reflection X-ray fluorescence spectrometry), Q-ICP-MS (quadrapole inductively coupled plasma mass spectrometry)... [Pg.219]

The quasi-simultaneous separation and determination of lanthanides and actinides by ion chromatography inductively coupled plasma mass spectrometry combined with the isotope dilution technique and the further use of ion chromatography for the determination of fission products and actinides in nuclear applications are described by Betti et ul.10 48 68... [Pg.423]

Arsenic specks have been determined in soil using inductively coupled plasma mass spectrometry coupled with secondary ion mass spectrometry and by ion exclusion chromatography coupled with plasma mass spectrometry [4]. [Pg.147]

In principle, all powerful element-specific methods that are able to monitor continuously the effluents of separation processes commonly in the range of a few mimin-1 and in element concentrations of some Klpg liter-1. A well-suited method is based on modern element-specific quadrupole mass spectrometry (MS) with an inductively coupled plasma (ICP) interface to the separation unit [e.g., liquid chromatography (LC) or field-flow fractionation (FFF)].Tlie ICP-MS detection can also be used for continuously characterizing the effluent of any kind of packed column (Metreveli and Frimmel, 2007). By this, the transport and elution properties of... [Pg.375]

S. Yali, G. Xiyun, D. Andao, Determination of platinum group elements by inductively coupled plasma-mass spectrometry combined with nickel sulphide E>re assay and tellurium coprecipitation, Spectrochim. Acta, 53B (1998), 1463D1467. [Pg.378]

Determination of trace elements in power plant emissions by inductively coupled plasma mass spectrometry comparison with other spectrometric techniques. Microchem J 59 203-218. [Pg.783]

Hill SJ, Bloxham MJ and Worsfold PJ (1993) Chromatography coupled with inductively coupled plasma emission spectrometry and with inductively coupled plasma mass spectrometry. J Anal At Spectrom 8 499-515. [Pg.1670]

Haldimann, M., Baduraux, M., Eastgate, A., Froidevaux, P., O Donovan, S., Von Gunten, D., and Zoller, O. 2001. Determining picogram quantities of uranium in urine by isotope dilution inductively coupled plasma mass spectrometry. Comparison with alpha-spectrometry. J Anal Atom Spectrom 16(12), 1364—1369. [Pg.447]

Shazali 1, Van t Dack L, Gijbels R (1987) Determination of precious metals in ores and rocks by thermal neutron activation/y-spectrometry after preconcentration by nickel sulfide fire assay and coprecipitation with tellurium. Anal Chim Acta 196 49-58 Stembeck J, Sjodin A, Andreasson K (2002) Metal emissions from road traffic and the influence of resuspension—results from two tunnel studies. Atmos Env 36 4735-4744 Sun Y, Guan X, Du A (1998) Determination of platinum group elements by inductively coupled plasma-mass spectrometry combined with nickel sulfide fire assay and tellurium coprecipitation. Spectrochim Acta B 53 1463-1467... [Pg.233]

Okuda T, Kato J, Mori J, Tenmoku M, Suda Y, Tanaka S, He KB, Ma YL, Yang F, Yu XC, Duan FK, Eei Y (2004) Daily concentrations of trace metals in aerosols in Beijing, China, determined by using inductively coupled plasma mass spectrometry equipped with laser ablation analysis, and source identification of aerosols. Sci Total Environ 330 145-158... [Pg.243]

Okuda,T.,Tenmoku, M., Kato, I, Mori, I, Sato,T.,Yokochi, R.,Tanaka, S. (2006) Long-term observation of trace metal concentration in aerosols at a remote island, Rishiri, lapan by using inductively coupled plasma mass spectrometry equipped with laser ablation. Water, Air, Soil Pollution, 174,3-17. [Pg.1226]

Hirata, T. (1996) Lead isotopic analyses of NIST Standard Reference Materials using multiple collector inductively coupled plasma mass spectrometry coupled with a modified external correction... [Pg.108]

Orihashi, Y., Nakai, S., and Hirata, T. (2008) U-Pb age determination for seven standard zircons using inductively coupled plasma-mass spectrometry coupled with frequency quintupled Nd-YAG (k = 213 nm) laser ablation system comparison with LA-ICP-MS zircon analyses with a NIST glass reference material. Res. Geol, 58, 101-123. [Pg.111]

N.G. Beck, R.P. Franks, and K.W. Bruland. Analysis for Cd, Cu, Ni, Zn, and Mn in estuarine water by inductively coupled plasma mass spectrometry coupled with an automated flow injection system. Analytica Chimica Acta 455 11-22, 2002. [Pg.302]

Bettinelli, M., Spezia, S., Baroni, U., and Bizzarri, G. (1998). Determination of trace elements in power plant emissions by inductively coupled plasma mass spectrometry Comparison with other spectrometric techniques. Microchem.J. 59(2), 203. [Pg.197]

Dziewatkoski, M. P., Daniels, L. B., and 01esik,J.W. (1996).Time-resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction. Ana/. Chem. 68(7), 1101. [Pg.208]


See other pages where Mass spectrometry coupling with inductively coupled is mentioned: [Pg.177]    [Pg.253]    [Pg.34]    [Pg.199]    [Pg.515]    [Pg.199]    [Pg.515]    [Pg.6084]    [Pg.1444]    [Pg.177]    [Pg.375]    [Pg.158]    [Pg.796]    [Pg.6083]    [Pg.102]    [Pg.123]    [Pg.2796]    [Pg.2797]    [Pg.375]    [Pg.478]    [Pg.259]    [Pg.145]    [Pg.3]   


SEARCH



Coupled spectrometry

Coupling spectrometry

Coupling with Mass Spectrometry

Couplings mass spectrometry

Inductive coupling

Inductively coupled

Inductively coupled mass spectrometry

Inductively mass spectrometry

© 2024 chempedia.info