Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Manipulating the numbers

Step 8 One method of solution is to solve all 12 equations simultaneously (the component material balances are nonlinear). By the following algebraic manipulations, the number of variables and equations can be reduced. Rearrange Eqs. (a)-(e). For example, for Eq. (a),... [Pg.322]

Of the 51 new drugs approved in fiscal year 1970, about 20 could be considered new entities —i.enew chemicals not previously marketed in the United States. However, many of these, although technically new entities, represented merely variations on familiar themes and in some cases nothing more than molecular manipulation. The number of new drugs approved in that period that could be considered as significant contributions to the pharmacopoeia is small indeed. [Pg.261]

A semi-systematic study of the hydrolysis of ethyl indole-2-carboxylate in aqueous media at high temperature indicated that decarboxylation of indole-2-carboxylic acid proceeded by an arenium ion mechanism and was inhibited by base. Because base facilitated hydrolysis of the ester, it was possible to obtain either the acid or indole from the ester merely by manipulating the number of equivalents of base present. [Pg.126]

By manipulating the number of aromatic ortAo-dihalide groups and catechols in the monomers, a PIM can be prepared either as an insoluble or soluble polymer network. For instance, a soluble PIM (PIM-1) is prepared from the reaction between 5,5, 6,6 -tetrahydro3gr-3,3,3, 3 -tetra-methyl-l,l -spirobisindane and tetrafluoroterephthalonitrile. On the other hand, HATN-network PIM is synthesized by the reaction between the readily available spiro-cyclic bis(catechol) monomer and hexachlorohexa-azatrinaphthylene. ... [Pg.41]

The supplier s laboratory has to design the assay and the respective OC curve in such a way that the OC curve fits between the points (0.05, 86) and (0.90, 95) as presented in Fig. 20.5. This can only be done by manipulating the number of replicates of the assay, because this is the only degree of freedom. The OC curve inclusive the number of replicates are derived from the limiting values LQL and a, AQL and p and not the other way around. [Pg.415]

The release process can be extended by manipulating the number of PE layers. [Pg.403]

The heat flow through the system can be manipulated by changing the number of stages. Figure 3.13c shows the effect of an increase from three to six stages. [Pg.87]

Equations 12.21 and 12.22 contain terms corresponding to column efficiency, column selectivity, and capacity factor. These terms can be varied, more or less independently, to obtain the desired resolution and analysis time for a pair of solutes. The first term, which is a function of the number of theoretical plates or the height of a theoretical plate, accounts for the effect of column efficiency. The second term is a function of a and accounts for the influence of column selectivity. Finally, the third term in both equations is a function of b, and accounts for the effect of solute B s capacity factor. Manipulating these parameters to improve resolution is the subject of the remainder of this section. [Pg.556]

Siace most fabricated elastomer products contain 10—50 vol % of filler, their physical properties and processing characteristics depend to a great extent on the nature and quaUty of the fillers. Rubber technologists manipulate the formula so as to optimize a large number of properties and keep costs down. [Pg.369]

Combinatorial Hbraries are limited by the number of sequences that can be synthesized. For example, a Hbrary consisting of one molecule each of a 60-nucleotide sequence randomized at each position, would have a mass of >10 g, weU beyond the capacity for synthesis and manipulation. Thus, even if nucleotide addition is random at all the steps during synthesis of the oligonucleotide only a minority of the sequences can be present in the output from a laboratory-scale chemical DNA synthesis reaction. In analyzing these random but incomplete Hbraries, the protocol is efficient enough to allow selection of aptamers of lowest dissociation constants (K ) from the mixture after a small number of repetitive selection and amplification cycles. Once a smaller population of oligonucleotides is amplified, the aptamer sequences can be used as the basis for constmcting a less complex Hbrary for further selection. [Pg.236]

Rules of matrix algebra can be appHed to the manipulation and interpretation of data in this type of matrix format. One of the most basic operations that can be performed is to plot the samples in variable-by-variable plots. When the number of variables is as small as two then it is a simple and familiar matter to constmct and analyze the plot. But if the number of variables exceeds two or three, it is obviously impractical to try to interpret the data using simple bivariate plots. Pattern recognition provides computer tools far superior to bivariate plots for understanding the data stmcture in the //-dimensional vector space. [Pg.417]

Distillation columns have four or more closed loops—increasing with the number of product streams and their specifications—all of which interact with each other to some extent. Because of this interaction, there are many possible ways to pair manipulated and controlled variables through controllers and other mathematical functions with widely differing degrees of effectiveness. Columns also differ from each other, so that no single rule of configuring control loops can be apphed successfully to all. The following rules apply to the most common separations. [Pg.747]

Often we will have data rather than a function and we wish to plot it, so that we can find a function that describes the data by analysis. In such cases we can manipulate the data by bringing it into a matrix form and then plotting it with ListPlot. We also can compare it to the behavior of functions that are meant to represent the data. The following is a typical set of data obtained from an experiment, appropriately named "data." (This could have been imported to Mathematica by any number of different means.) The first column is time and the second is the value of the measured variable in the system ... [Pg.30]

As you work with Fischer projections, you may notice that some routine strrrctural changes lead to pr edictable outcomes—outcomes that may r educe the number of manipulations you need to do to solve stereochemistry problems. Instead of listing these shortcuts, Problem 7.10 invites you to discover some of them for yourself. [Pg.294]

Besides the above-mentioned problems with step control, there are also other computational aspects which tend to make the straightforward NR problematic for many problem types. The true NR method requires calculation of the full second derivative matrix, which must be stored and inverted (diagonalized). For some function types a calculation of the Hessian is computationally demanding. For other cases, the number of variables is so large that manipulating a matrix the size of the number of variables squared is impossible. Let us address some solutions to these problems. [Pg.319]

An alternative approach to asymmetric synthesis that avoids covalent modification of the substrate is chiral modification of the active reagent. This not only streamlines the number of synthetic manipulations, but it simplifies the isolation of the desired product. In the case of zinc carbenoids, such modifications are feasible alternatives to the use of a standard chiral auxiliary. Two important factors combine... [Pg.115]


See other pages where Manipulating the numbers is mentioned: [Pg.65]    [Pg.397]    [Pg.895]    [Pg.476]    [Pg.183]    [Pg.53]    [Pg.364]    [Pg.73]    [Pg.135]    [Pg.65]    [Pg.397]    [Pg.895]    [Pg.476]    [Pg.183]    [Pg.53]    [Pg.364]    [Pg.73]    [Pg.135]    [Pg.356]    [Pg.1450]    [Pg.1671]    [Pg.243]    [Pg.575]    [Pg.228]    [Pg.247]    [Pg.60]    [Pg.72]    [Pg.75]    [Pg.103]    [Pg.724]    [Pg.1826]    [Pg.90]    [Pg.23]    [Pg.382]    [Pg.507]    [Pg.824]    [Pg.116]    [Pg.212]    [Pg.284]    [Pg.77]   
See also in sourсe #XX -- [ Pg.59 , Pg.60 , Pg.62 , Pg.70 , Pg.71 , Pg.97 ]




SEARCH



© 2024 chempedia.info