Makeup water

Hydrating bentonite in fresh water before adding it to the mud greatly increases its efficiency when the makeup water is contaminated with salt and/or hardness. Prehydrated bentonite can be protected from dehydration by flgnosulfonate (70) or sulfomethylated tannin when used in saturated salt water. Salt water clays, such as sepioflte and attapulgite, provide no filtration control and are normally used with suitable filtration control agents. [Pg.180]

Demineralizers are often used to treat raw makeup water or condensate where high purity is required, such as in large central station boHers that operate at high steam pressures. Demineralizers employ a combination of cation and anion exchange to remove additional material, including sodium and ammonium cations. VirtuaHy aH salt anions, such as bicarbonate, sulfate, and chloride, are removed and replaced by hydroxide ions in the demineralizer. [Pg.7]

Makeup. Makeup water is the water suppHed to replenish the steam system for any losses. In most systems it is introduced into the condenser or the feed pump suction. In steam systems where the makeup is a small fraction of the total feedwater, its purity may be somewhat lower than the feedwater requirement because it is diluted by condensate. In systems where there is Httie condensate return, such as heating steam suppHes, the makeup purity must be essentially the same as the feedwater. [Pg.361]

Makeup. Makeup treatment depends extensively on the source water. Some steam systems use municipal water as a source. These systems may require dechlorination followed by reverse osmosis (qv) and ion exchange. Other systems use weUwater. In hard water areas, these systems include softening before further purification. Surface waters may require removal of suspended soHds by sedimentation (qv), coagulation, flocculation, and filtration. Calcium may be reduced by precipitation softening or lime softening. Organic contaminants can be removed by absorption on activated carbon. Details of makeup water treatment may be found in many handbooks (22—24) as well as in technical Hterature from water treatment chemical suppHers. [Pg.363]

Tar sand feed contains a certain portion of fine minerals that, if allowed to build up in concentration in the middlings, increases viscosity and eventually dismpts settling ia the separation cell. The drag stream is required as a purge in order to control the fines concentration in the middlings. The amounts of water that can enter with the feed and leave with the separation cell tailings and froth are relatively fixed. Thus, the size of the drag stream determines the makeup water requirement for the separation cell. [Pg.358]

The quahty of feed water required depends on boiler operating pressure, design, heat transfer rates, and steam use. Most boiler systems have sodium zeohte softened or demineralized makeup water. Feed-water hardness usually ranges from 0.01 to 2.0 ppm, but even water of this purity does not provide deposit-free operation. Therefore, good internal boiler water treatment programs are necessary. [Pg.263]

High Pressure Boiler Water Treatment. High pressure boilers usually have feed water composed of demineralized makeup water and a high percentage of condensate returns. Because of these conditions, high pressure boilers are prone to caustic and acid attack. Low pressure boilers that use dernineralized water and condensate as feed water are also susceptible to caustic and acid attack. [Pg.264]

Foulants enter a cooling system with makeup water, airborne contamination, process leaks, and corrosion. Most potential foulants enter with makeup water as particulate matter, such as clay, sdt, and iron oxides. Insoluble aluminum and iron hydroxides enter a system from makeup water pretreatment operations. Some well waters contain high levels of soluble ferrous iron that is later oxidized to ferric iron by dissolved oxygen in the recirculating cooling water. Because it is insoluble, the ferric iron precipitates. The steel corrosion process is also a source of ferrous iron and, consequendy, contributes to fouling. [Pg.271]

Removal of Particulate Matter. The amount of particulate entering a cooling system with the makeup water can be reduced by filtration and/or sedimentation processes. Particulate removal can also be accompHshed by filtration of recirculating cooling water. These methods do not remove all of the suspended matter from the cooling water. The level of fouling experienced is influenced by the effectiveness of the particular removal scheme employed, the water velocities in the process equipment, and the cycles of concentration maintained in the cooling tower. [Pg.271]

Cla.riGers. Pool water may occasionally contain metallic impurities such as copper, iron, or manganese which enter the pool with the makeup water or by corrosion of metallic parts in the circulation system. These dissolved metals can discolor the water and cause stains. Chlorine oxidizes soluble Fe and to the highly insoluble Fe(OH)3 and MnO which can be removed by filtration. Water-soluble, high molecular weight polymers can be... [Pg.302]

A float valve is provided to control the supply of makeup water to replace the water vapor that has flashed off, Tne flash tank should be insulated. [Pg.1122]

Example 4 Evaporative Cooling Air at 95 F dry-bulb temperature and 70 F wet-bulb temperature contacts a water spray, where its relative humidity is increased to 90 percent. The spray water is recirculated makeup water enters at 70 F. Determine exit dry-bulb temperature, wet-bulb temperature, change in enthalpy of the air, and quantity of moisture added per pound of dry air. [Pg.1153]

Solution. Figure 12-8 shows the path on a psychrometric chart. The leaving dry-bulb temperature is obtained directly from Fig. 12-2 as 72.2 F. Since the spray water enters at the wet-bulb temperature of 70 F and there is no heat added to or removed from it, this is by definition an adiabatic process and there will be no change in wet-bulb temperature. The only change in enthalpy is that from the heat content of the makeup water. This can be demonstrated as follows ... [Pg.1153]

Example 6 Cooling Tower Determine water consumption and amount of heat dissipated per 1000 ftVmin of entering air at 90 F drydsulb temperature and 70 F wet-bulb temperature when the air leaves saturated at 110 F and the makeup water is at 75 F. [Pg.1153]

Blowdown discards a portion of the concentrated circulating water due to the evaporation process in order to lower the system solids concentration. The amount of blowdown can be calculated according to the number of cycles of concentration required to limit scale formation. Cycles of concentration are the ratio of dissolved sohds in the recirculating water to dissolved solids in the makeup water. Since chlorides remain soluble on concentration, cycles of concentration are best expressed as the ratio of the chloride content of the circulating and makeup waters. Thus, the blowdown quantities required are determined from... [Pg.1165]

Example 13 Calculation of Makeup Water Determine the amount of makeup required for a cooling tower with the following conditions ... [Pg.1165]

Incineration with Heat Recovery Heat contained in the gases produced from the incineration of solid wastes can be recovered as steam. The low-level heat remaining in the gases after heat recoveiy can also be used to preheat the combustion air, boiler makeup water, or solid-waste fuel. [Pg.2243]

Wastage was caused by classic long-term underdeposit corrosion. The combined effects of oxygen concentration cells, low flow, and contamination of system water with high chloride- and sulfate-concentration makeup waters caused corrosion. [Pg.94]

Isolate and identify possible sources of in-leakage, such as perforated heat exchangers or makeup water contamination. [Pg.171]

Whatever the water composition, corrosivity can be increased by evaporation, which may elevate pH by increasing concentrations of ions in the remaining liquid. This is the reason that cooling systems that experience boiling and/or large evaporative losses without sufficient makeup water additions may be especially prone to attack. Cycling may also increase dissolved species concentrations. [Pg.187]

Knox has provided the following graphs for estimating the required vent steam from boiler feedwater deaerators. Vent steam rate depends upon the type of deaerator (spray or tray type) and the percentage of makeup water (in contrast to returning condensate). Low makeup water rates require relatively lower steam vent rates, but there is a minimum rate required to remove CO2 from the returning condensate. [Pg.144]

Concentration Cycles Comparison of dissolved solids in makeup water with solids concentration in the circulating water. [Pg.90]

A flare seal drum may also be used as a sour water disengaging drum, if economically advantageous. In such cases, special care should be given to ensure that the drum is adequately sized to simultaneously meet all design features required for both functions. Also a separate source of makeup water must still be provided to ensure continuity of the seal. [Pg.272]

Core damage can result most likely from heat imbalance. Figure 6.3-3 is an example from the Indian Point PRA that uses heat imbalance to approach completeness. This diagram shows that cote damage may result from either a loss of cooling or excess power (or both). The direct causes of insufficient heat removal may be loss of flow, makeup water, steam flow, or heat extraction by the turbine. Indirect causes are reactor trip or steam line break inside or outside of containment. Cau.ses of excess power production are rod withdrawal, boron removal, and cold water injection. [Pg.233]

Answer Figure 15.5.2-2 shows an automatic depressurization valve that opens on excessive conditions to release the steam which passes through a turbine to drive an electric generator to provide makeup water and operate other cooling equipment. After the steam has cooled in the low pressure turbine it discharges under water in the cooling reservoir and condensed. The reservoir cools by evaporation. [Pg.503]


See other pages where Makeup water is mentioned: [Pg.362]    [Pg.191]    [Pg.178]    [Pg.327]    [Pg.327]    [Pg.524]    [Pg.7]    [Pg.358]    [Pg.267]    [Pg.271]    [Pg.272]    [Pg.295]    [Pg.270]    [Pg.1149]    [Pg.1165]    [Pg.3]    [Pg.90]    [Pg.398]    [Pg.226]    [Pg.259]    [Pg.375]    [Pg.128]    [Pg.267]    [Pg.276]    [Pg.98]    [Pg.420]   
See also in sourсe #XX -- [ Pg.12 , Pg.13 ]




SEARCH



Aeration Towers for Makeup Water Pretreatment

Basin.Water Makeup System

Condensers makeup water

Cooling towers water makeup

Cooling water makeup

DEMINERALIZED WATER MAKEUP

Feedwater Contamination from Makeup Water

Makeup

Makeup water sources and their impurities

Makeup water to replace

Reactor makeup water storage tank

Sources of Water for Cooling System Makeup