Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Maintenance cleaning corrosion

They should be checked regularly for precision and accuracy of delivery volumes. Instructions on how to do this are usually included with the pipets If not, ask the manufaeturer how they are to be checked. Limited maintenance of the pipets should be made with attention to the plimgers in multichannel pipets, which get contaminated. Care should be taken to make sure that liquids are not pulled into the pipet if so, they must be cleaned. Corrosion ean occur when, e.g., sulfuric acid stopping reagent is taken into the body of a pipet. [Pg.78]

A development of interest to the chemical industiy is the tubular precipitator of reinforced-plastic construction (Wanner, Gas Cleaning Plant after T1O2 Rotary Kilns, technical bulletin, Lurgi Corp., Frankfurt, Germany, 1971). Tubes made of polyvinyl chloride plastic are reinforced on the outside with polyester-fiber glass. The use of modern economical materials of construction to replace high-maintenance materials such as lead has been long awaited for corrosive applications. [Pg.1616]

Emission of toxic, flammable or corrosive vapors when equipment is opened for clean-ing/maintenance or during charging of hazardous material. Possibility for operator exposure. [Pg.52]

This chapter deals with the essential factors in the selection of systems and equipment during the design stage principles of controls, noise-reduction systems, and problems such as erosion, corrosion, maintenance and equipment cleaning, etc. [Pg.679]

The manuals provided by the equipment manufacturers should indicate the recommended preventive maintenance tasks and the frequency they should be performed covering such aspects as cleaning, adjustments, lubrication, replacement of filters and seals, inspections for wear, corrosion, leakage, damage, etc. [Pg.361]

Operating and Maintenance Costs mechanical details must account for the peculiarities of the system fluids (coking, suspended particles, immiscible fluids, etc.) and accommodate the requirements for drainage, cleaning (chemical or mechanical), corrosion, etc., in order to keep the daily costs of operation and downtime to a minimum. [Pg.126]

Excessive particulate contamination of the fluid indicates that the filters are not keeping the system clean. This can result from improper filter maintenance, inadequate filters, or excessive ongoing corrosion and wear. [Pg.604]

All the foregoing has been concerned with the initial protection of steelwork, but there is far more maintenance painting than new work. The same principles apply to maintenance painting, with the exception that it is often only in isolated patches and in complicated situations, such as around flanges, etc. that the steelwork is bare of paint, and then it is frequently heavily contaminated with corrosion products. The first necessity, therefore, is to clean down these areas to bare steel, but often it is not possible to use blasting methods. Often hand cleaning is all that can be done. Careful supervision is needed, and the cleaned areas must be primed without delay and then brought forward with a suitable anti-corrosive system. [Pg.643]

Control of foulants and corrosion debris Because of the very large volume in these HW systems, there is an obvious reluctance to unnecessarily drain them down because of the development of waterside problems. Therefore, it is important to ensure that before regular operation they are provided with a proper precommission cleaning procedure. This process removes silt, mill-scale, grease, and other foulants, thus enabling passivation and subsequent maintenance inhibition to take place. [Pg.187]

Online passivation involves elevating the corrosion inhibitor concentration as high as three times normal maintenance levels. At higher concentrations, the rate at which the protective film forms is accelerated. This, in turn, reduces the degree of initial corrosion on clean but unprotected metal surfaces. The rate at which corrosion protection takes place depends on the temperature, pH and inhibitor used. [Pg.189]

During an on-line clean, the quality of the clean will normally be enhanced by the use of an initial chlorine dosing procedure at a pH of 7.2 to 7.6. This practice is to be recommended, irrespective of whether the current cooling system maintenance biocide program employs chlorine. With severely fouled cooling systems, it may be necessary to provide many hundreds of ppm of HOC1 in order to satisfy the oxidation demand. This in turn may require the use of a temporary, supplementary corrosion inhibitor, and almost certainly the use of some antifoam. [Pg.347]

Good care and maintenance of a firearm are the best protection against corrosion. There is a wide range of commercial gun cleaning and maintenance products available. [Pg.100]


See other pages where Maintenance cleaning corrosion is mentioned: [Pg.248]    [Pg.362]    [Pg.287]    [Pg.291]    [Pg.207]    [Pg.2435]    [Pg.410]    [Pg.416]    [Pg.226]    [Pg.147]    [Pg.127]    [Pg.76]    [Pg.288]    [Pg.799]    [Pg.10]    [Pg.21]    [Pg.192]    [Pg.16]    [Pg.6]    [Pg.41]    [Pg.53]    [Pg.207]    [Pg.10]    [Pg.129]    [Pg.136]    [Pg.25]    [Pg.91]    [Pg.253]    [Pg.321]    [Pg.83]    [Pg.362]    [Pg.2190]    [Pg.22]    [Pg.714]   
See also in sourсe #XX -- [ Pg.23 , Pg.77 ]




SEARCH



Maintenance Cleaning