Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Magnesium detection

FIGURE 32. Magnesium concentration as a function of argon ion bombardment dose for the various pretreated alloys (a) degreased (note no magnesium detected in the EIC oxide layer) (b) phosphoric acid anodized. Reprinted with permission from Reference 36. Copyright 1982 Gordon and Breach Science Publishers. [Pg.198]

C12H9N3O4. A brownish-red powder, soluble in sodium hydroxide. Used for the detection and estimation of magnesium, with which it forms a blue lake in alkaline solutions. [Pg.246]

Other methods for analyzing combustion products can be substituted for chromatography. Gravimetry can be used, for example, after a series of absorption on different beds, as in the case of water absorption in magnesium perchlorate or CO2 in soda lime infra-red spectrometry can be used for the detection of CO2 and water. [Pg.29]

Glyoxylic acid solution (protein detection) cover 10 g of magnesium powder with water and slowly add 250 mL of a saturated oxalic solution, keeping the mixture cool filter off the magnesium oxalate, acidify the filtrate with acetic acid and make up to a liter with water. [Pg.1191]

Significant vapor pressure of aluminum monofluoride [13595-82-9], AIF, has been observed when aluminum trifluoride [7784-18-1] is heated in the presence of reducing agents such as aluminum or magnesium metal, or is in contact with the cathode in the electrolysis of fused salt mixtures. AIF disproportionates into AIF. and aluminum at lower temperatures. The heat of formation at 25°C is —264 kJ/mol(—63.1 kcal/mol) and the free energy of formation is —290 kJ/mol(—69.3 kcal/mol) (1). Aluminum difluoride [13569-23-8] h.3.s been detected in the high temperature equihbrium between aluminum and its fluorides (2). [Pg.140]

Magnesium, calcium, barium, and strontium can also be deterrnined by ion chromatography with y -phenylenediamine in perchloric acid as the eluent. Ion chromatography by conductimetric detection has been described, and appHcations to environmental waters have been discussed (1,22—23). [Pg.231]

This procedure was tested in the analysis of pharmaceutical products Poltava s bishofite (series Elite and Profi ) and a brine of bischofite with rusty precipitate. The data bear out the sufficient accuracy and reproducibility of the proposed procedure which allows to perform the determination magnesium, iron, copper and zinc ions at concentrations above 10 M. It was found that the content of Mg ion in the studied brine decreases in comparison with Poltava s bishofite . The Fe, Cu and Zn ions were not detected in the brine. [Pg.396]

Cathodic protection with impressed current, aluminum or magnesium anodes does not lead to any promotion of germs in the water. There is also no multiplication of bacteria and fungi in the anode slime [32,33]. Unhygienic contamination of the water only arises if anaerobic conditions develop in the slurry deposits, giving rise to bacterial reduction of sulfate. If this is the case, HjS can be detected by smell in amounts which cannot be detected analytically or by taste. Remedial measures are dealt with in Section 20.4.2. [Pg.462]

B. Back-titration. Many metals cannot, for various reasons, be titrated directly thus they may precipitate from the solution in the pH range necessary for the titration, or they may form inert complexes, or a suitable metal indicator is not available. In such cases an excess of standard EDTA solution is added, the resulting solution is buffered to the desired pH, and the excess of the EDTA is back-titrated with a standard metal ion solution a solution of zinc chloride or sulphate or of magnesium chloride or sulphate is often used for this purpose. The end point is detected with the aid of the metal indicator which responds to the zinc or magnesium ions introduced in the back-tit ration. [Pg.311]

Addilion of benzophenone to the lithium derivative 2 (M = Li) proceeds in a stereorandom fashion, which is attributed to the participation of radicals, detected by ESR and produced by single-electron transfer (SET)12. The magnesium derivative reacts with 90% diastereoselectivity with no SET being recorded. Benzaldehyde as the carbonyl compound affords the [1/, 1(1S)]-and [15,1(1/ )]-diastereomers in a 70 30 mixture, with 40% de12. Enhanced selectivities are achieved with camphor-derived 2-(2-oxazolyl)isoquinolines12a. [Pg.202]

Fhtients with hypomagnesemia (low magnesium plasma levels) are at increased risk for digitalis toxicity. If low magnesium levels are detected, die primary care provider may prescribe magnesium replacement dierapy. [Pg.364]

The alkaline earth metals can be detected in burning compounds by the colors that they give to flames. Calcium burns orange-red, strontium crimson, and barium yellow-green. Fireworks are often made from their salts (typically nitrates and chlorates, because the anions then provide an additional supply of oxygen) together with magnesium powder. [Pg.714]

If the bacterial content of an inanimate suspension, i.e. a medicine such as milk of magnesia, is being examined both bacteria and magnesium hydroxide particles will be detected, although here again methods of distinguishing the two types of particle have been developed. [Pg.24]

Other electrolytes of importance include calcium (especially if the patient is receiving a calcium channel blocker, such as nicardipine) and magnesium, as hypomagnesemia may predispose the patient to seizures, further complicating the ICP management. If the patient received intravenous iodinated contrast as part of their stroke evaluation, then careful monitoring of the blood urea nitrogen (BUN) and creatinine levels is necessary to detect contrast nephropathy. [Pg.166]

In the OH series, two phases were detectable by XRD in the dried precipitate. One was a phase with the pyroaurite structure, carbonate having presumably arisen from atmospheric CO2, and the other brucite, Mg(OH)2, 0 which pyroaurite is closely related structurally. For both the CCP and IP series, the only structure identifiable in the dried precipitate was that of magnesium hydroxy carbonate. X-ray analysis of the calcined precursors showed MgO together with y-Fe203 in the case of the OH series and HT, but -Fe203 with the CCP and IP series. MgFe204 spinel was also detectable in some cases. [Pg.260]

Shi, H., Zhang, R., Chandrasekher, G., and Ma, Y., Simultaneous detection and quantitation of sodium, potassium, calcium and magnesium in ocular lenses by high-performance capillary electrophoresis with indirect photometric detection, ]. Chromatogr. A, 680, 653 1994. [Pg.422]

A method for determining the caffeine content of regular and decaffinated green and roasted coffee beans and of regular and decaffeinated coffee extract powders, using HPLC, is specified in a British Standard Instruction.34 Caffeine is extracted from the sample with water at 90°C in the presence of magnesium oxide. The mixture is filtered and an aliquot purified on a silica microcolumn modified with phenyl groups. The caffeine content is then determined by HPLC with UV detection.35... [Pg.34]

The photophysical properties of magnesium(II) tetra-(i-butyl)phthalocyanine (27) have been studied in solution, in micelles and in liposomes cation radical formation (CBr4 as electron acceptor) has been detected with UV excitation, or by a two-photon excitation using a pulsed laser in the therapeutic window at 670 nm.118 The Mg11 complex of octa(tri-z -propylsilylethy-nyl)tetra[6,7]quinoxalinoporphyrazine (28) has been prepared as a potential PDT sensitizer. The synthesis is shown in Figure 8. Compound (28) has Amax 770 nm (e = 512,000 M-1 cm-1), d>f = 0.46 and d>A = 0.19 (all in THF, under air).119... [Pg.969]


See other pages where Magnesium detection is mentioned: [Pg.5596]    [Pg.5596]    [Pg.611]    [Pg.275]    [Pg.332]    [Pg.439]    [Pg.387]    [Pg.410]    [Pg.306]    [Pg.4]    [Pg.61]    [Pg.108]    [Pg.109]    [Pg.912]    [Pg.142]    [Pg.283]    [Pg.105]    [Pg.454]    [Pg.402]    [Pg.53]    [Pg.118]    [Pg.10]    [Pg.42]    [Pg.112]    [Pg.299]    [Pg.328]    [Pg.292]    [Pg.253]    [Pg.51]    [Pg.78]    [Pg.210]    [Pg.520]    [Pg.319]    [Pg.144]   
See also in sourсe #XX -- [ Pg.78 , Pg.79 , Pg.80 ]




SEARCH



Magnesium analysis detection limits

© 2024 chempedia.info