Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Lower extremities applications

Stanethylium. When a strip of zinc is immeised in a solution of a salt of stanethylium (a solution of the chloride of stanethylium is the best for this purpose), it speedily becomes covered with dense oily drops of a yellow colour, which finally separate from the lower extremity of the zinc and accumulate at the bottom of the vessel the formation of the oily liquid is much favoured by the application of a gentle heat The yellow oil was separated from the supernatant liquid by means of a pipette, and well washed with successive large portions of cold water being then dried over chloride of calcium and submitted to analysis, it yielded the following results — ... [Pg.82]

The important role of risk assessment is to inform the public health decision process so that responsible decisions in the interest of public health can be made. Extreme application of the precautionary principle, whether motivated by public expectations or regulatory desire to achieve ever lower risk, can lead to a virtual zero tolerance policy it is the role of risk assessment founded on scientific principles to advise the reasonableness of these policy decisions. [Pg.21]

It is clear that the multilink systems of Figs. 7.4, 7.5, and 7.6 are applicable to many biodynamic scenarios. They can represent a torso with an upper or lower extremity, as well as several oilier combinations of multibody problems, as can be seen within the cited references. [Pg.193]

Polymers are used for biological applications in a variety of situations from drug carriers to components of artificial limbs, in an instance of replacement of live tissue, PTFE grafts are used to treat lower-extremity ischaemia when autologus saphenous veins are unavailable. As a step toward understanding the ensuing complications and tissue build-up, a graft was simulated in a flow device [49 ]. The con-... [Pg.150]

In the end, all these factors result in very high part cost and restrict the volume to relatively low numbers per day. This has driven continuing development to try and reduce the manufacturing costs, starting in the segments of lower performance applications where the extreme cost of autoclaves could not be warranted. The development made in these low end performance sectors has fundamentally changed the entire composites manufacturing market. [Pg.436]

Practical Applications and Case Histories of the Lower Extremities... [Pg.537]

Though there have been several studies about the modeling of the lower extremities [4,5], the application of this modeling to hip fracture reduction is not found. In this study, the musculoskeletal modeling method is introduced, and the model is applied to the hip fracture. Finally, the reduction force is simulated for two reduction paths. [Pg.116]

This Handbook is organized into three main sections. The first section, which consists of three chapters, reviews the basic scientific, engineering, and clinical foundations for UHMWPE. For example, in Chapter 2, we explain how UHMWPE must be formed into bulk components from the resin powder using extrusion or compression molding techniques. In Chapter 3, we review the techniques associated with sterilization and packaging of UHMWPE implants. Chapters 5-12 cover the basic clinical applications of UHMWPE in the lower extremities, upper extremities, and the spine. [Pg.6]

The topics outlined in this Handbook may be used as a resource in undergraduate, as well as graduate, courses in biomaterials and orthopedic biomechanics. Students in these disciplines can learn a great deal from exposure to the historical development of total joint replacements within the context of UHMWPE. The first main sections of this book, which cover the fundamentals of UHMWPE and clinical applications in the spine and upper and lower extremities, are intended as a resource for undergraduate instruction. [Pg.6]

In another case study involving a different foundry, a 90% AI2O3 brick was examined for evidence of corrosion after service in a ferrous foundry furnace hearth/lower sidewall application. The premature failure was in a skewback brick at the furnace hearth that was supporting the lower furnace sidewalls. A photograph of a brick after service is shown in Figure 12. Because of the extreme wear of the brick, it was suspected that corrosion was a cause of failure. [Pg.58]


See other pages where Lower extremities applications is mentioned: [Pg.505]    [Pg.567]    [Pg.507]    [Pg.817]    [Pg.1217]    [Pg.86]    [Pg.900]    [Pg.246]    [Pg.1392]    [Pg.246]    [Pg.253]    [Pg.629]    [Pg.309]    [Pg.62]    [Pg.150]    [Pg.30]    [Pg.311]    [Pg.229]    [Pg.506]    [Pg.541]    [Pg.543]    [Pg.547]    [Pg.321]    [Pg.986]    [Pg.464]    [Pg.160]    [Pg.1457]    [Pg.539]    [Pg.264]    [Pg.1474]    [Pg.730]    [Pg.102]    [Pg.16]    [Pg.83]    [Pg.191]    [Pg.725]    [Pg.1187]    [Pg.394]    [Pg.147]    [Pg.272]   
See also in sourсe #XX -- [ Pg.537 , Pg.538 , Pg.539 , Pg.540 , Pg.541 , Pg.542 , Pg.543 , Pg.544 ]




SEARCH



Extreme

Extremities

Extremizer

Lower extremities

© 2024 chempedia.info