Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Lower control unit

LCL lower control unit LMDPE hnear medium density polyethylene... [Pg.600]

The extract collection unit consists of a turntable with provision for holding 20 glass or polypropylene tubes. Two pneumatic pistons are used to raise and lower the probe and to rotate it through 90° to position it either over a tube for collection of extract or over a waste outlet for rinsing during the wash cycle. Both the rotation of the turntable and the movement of the probe are controlled by the central control unit. [Pg.129]

The data in Table 26.3 are CIE LCH DH values as measured against a reference standard for several consecutive production runs. The time order for these values is given by reading down each column, beginning with the column on the left. The DH average range R from previous runs of the same product is 0.158 units when this value is divided by d2 = 1.128, we get an estimated standard deviation of 0.14 DH units. The midpoint of the DH specification for this product is 0.0. If 0.0 is taken as the central line for a control chart for individual values, then this chart will have the following upper and lower control limits (LCL, UCL) ... [Pg.394]

Soluble insulin, preferably from the same species the patient has been using (never a sustained-release form), should be given by continuous i.v. infusion of a 1 unit/ml solution of insulin in isotonic sodium chloride. It is best to use a pump, which allows independent control of insulin and electrolyte administration more readily than an i.v. drip. If a pump is not available, the insulin should be added in a concentration of 1 unit/ml to 50-100 ml of sodium chloride in a burette. The infusion rate is determined by a sliding scale, as illustrated in Table 35.2. The rate is adjusted hourly using the same scale. If an i.v. drip is used instead of a pump the concentration should be lower (40 units/I). Stringent precautions against septicaemia are necessary in these patients. Continuous infusion i.m. (not s.c.) can also be equally effective, provided the patient is not in shock and provided there is not an important degree of peripheral vascular disease. [Pg.693]

Since the first phase seemed to respond so well as a single digester at most of the pH values in the normally productive range, the experiment was enlarged, and three digesters were set up. One was used as a control, and in the other two the pH was lowered in steps using HCl fed by automatic titrimeter in one and by an electrical control in the other. The pH was monitored by a timer every 15 minutes in all digesters, and each of the controlled units was automatically adjusted if needed to the desired level. [Pg.123]

Compaction simulators (Fig. 20) were designed to mimic the compression cycle of any prescribed shape by using hydraulic control mechanisms that are driving a set of two punches (upper and lower) in and out of the die. All hydraulic compaction simulators are similar in design and construction. A compaction simulator consists of several main units the load frame (column supports and crossheads with punches), the hydraulic unit (pumps and actuators that move the crossheads), and the control unit (electronic console and computer). Usually, a simulator accepts F tooling only, but can be retrofitted to use standard IPX B tooling. Under computer control, the hydraulic actuators maintain load, position, and strain associated with each punch. [Pg.3698]

The nylon machines, of course, must be well heated and insulated, but they can be lower pressure units, have lower injection rates and have less need for accurate ratio control. [Pg.158]

For bus systems there are several standard or quasi-standard bus structures available. For high-speed connection you can use the popular automotive CAN bus (control area network) or the SPI interface (serial peripheral interface) often used to connect the sensor to the microcontroller inside the control unit For lower speeds the LIN bus (local interconnect network) is available. In both cases a microcontroller inside the sensor unit is necessary, which works with a stable quartz clock frequency. [Pg.267]

The non-rotating lower platen of the measming assembly is fixed to a height-adjustable pneumatic ram which may be raised to provide the desired gap setting, with micrometer-fine adjustment. A temperatme control unit is... [Pg.50]

If the solvent concentration of a zone exceeds certain level, then the system becomes to be in danger of explosion due to the flammability of organic solvent vapor. This level of solvent concentration is called as lower explosive level (LEL), and the dryer should be operated below the LEL prior to any constraints. Thus each zone needs sufficient airflow rate to meet these needs. However, too much airflow rate results in waste of energy to heat the excess air, and it increases the load ofwaste gas facilities (e.g., VOC emission control units). Therefore the airflow rate of each zone and the ratio of recycled to fresh air should be optimized. The typical airflow system for a multiple zone dryer is shown in Figure 7.3.32. The supplying air of each zone is consisted of fresh and recycled (used or returned from the exit gas) air as shown in the figure. LEL can be calculated if we know the evaporation rate of solvent of a zone. The evaporation rate of solvent can be measured or calculated as we explained in previous sections. Thus we can distribute the fresh air to each zone to meet the LEL safety without substantial increase in the total exhaust air. [Pg.414]

A Matlab-oriented view is proposed in figure 7, here the upper part shows the normal communication path, similar to sensor —> processing —> actuators, the lower part shows input values which are preprocessed by an external Electronic Control Unit (ECU). The middle... [Pg.1440]

The liquid and gaseous emisapns jare better controlled and much lower per unit of production than in small local plants. [Pg.355]


See other pages where Lower control unit is mentioned: [Pg.610]    [Pg.99]    [Pg.314]    [Pg.99]    [Pg.50]    [Pg.330]    [Pg.39]    [Pg.1039]    [Pg.99]    [Pg.273]    [Pg.104]    [Pg.123]    [Pg.182]    [Pg.272]    [Pg.106]    [Pg.3928]    [Pg.16]    [Pg.152]    [Pg.99]    [Pg.343]    [Pg.9]    [Pg.316]    [Pg.496]    [Pg.99]    [Pg.144]    [Pg.421]    [Pg.1001]    [Pg.701]    [Pg.484]    [Pg.388]    [Pg.230]    [Pg.43]    [Pg.388]    [Pg.277]    [Pg.1185]    [Pg.1887]   
See also in sourсe #XX -- [ Pg.600 ]




SEARCH



Controls lower

© 2024 chempedia.info