Local ion current

Norma Ii zat i on of the features is performed with respect to the sum of all peak heights ("total ion current ) C1411, or with respect to the sum of the squared peak heights (t.m. all spectra lie on a hypersphere) C59, 2353. A valuable preprocessing is "normalization to local ion current" C217, 250, 4133. Each peak height is divided by the sum of peak heights in a window of several mass units. [Pg.148]

Table 11 compares some preprocessing methods for mass spectra of steroids C2513. Normal spectra and spectra normalized to local ion current show the best classification- These results are valid only for a certain classification procedure and only for steroid mass spectra-Nevertheless, qualitative conclusions may be drawn also for other methods or other types of compounds-... [Pg.150]

Even though it is beyond the scope of this book, micropipette electrodes are also used as probes in the SICM to image local ion currents. Recently, the SICM operated with distance-modulated feedback allowed to record simultaneously topographical and local ion current images of ion... [Pg.264]

It is possible that the stationary-state situations leading to an active ion transport occur only in localized regions of the membrane, i.e., at ATPase molecule units with diameters of about 50 A and a length of 80 A. The vectorial ion currents at locations with a mixed potential and special equipotential lines would appear phenomenologically like ionic channels. If the membrane area where the passive diffusion occurs is large, it may determine the rest potential of the whole cell. [Pg.239]

Table V summarizes all the sharp absorptions due to local modes of vibration in proton and deuteron implanted GaP, GaAs and InP. It has to be noted that the results depend upon the reports. For instance, for GaP implanted with protons, Newman and Woodhead (1980) observed only one line at 1849 cm-1 whereas Sobotta et al. (1981) observed only one line at 2204 cm-1. These differences probably come from the differences in implantation conditions. However, unfortunately, these conditions are not always well described in the literature the ion energy and dose are usually given, but the ion current is specified only by Tatarkiewicz et al. (1987, 1988). This parameter is of importance as it contributes to control local temperature and therefore the defect creation and the binding of hydrogen to the lattice. [Pg.509]

Myelin facilitates conduction. Myelin is an electrical insulator, although its function of facilitating conduction in axons has no exact analogy in electrical circuitry [3], In unmyelinated fibers, impulse conduction is propagated by local circuits of ion current that flow into the active region of the axonal membrane, through the axon, and... [Pg.51]

The AChR consists of five subunits surrounding an ion-conducting channel (Fig. 28.2). Activation of the binding sites on the two a-subunits results in a conformational change. This allows the simultaneous inflow of Na+ and Ca++ and outflow of K+, with a net inflow of positive charge. The response to a spontaneously secreted quantum of ACh (that is, activation of several thousand AChRs) is seen as a miniature EPC. With nerve stimulation, many quanta are released synchronously to produce a fuU-sized EPC, which is the sum-mated response of the 200 or so individual miniature EPCs. The EPC is a local graded current that in normal conditions triggers an action potential in the adjacent muscle membrane (Fig. 28.1). [Pg.338]

Despite the continuing debate, there is much that is known about anesthetic action. It is clear that local anesthetics significantly change ion currents across neural membranes, that the ion channels through which they pass are composed of protein, and that these proteins are embedded in lipid [53]. However, there is little knowledge of the mechanism by which lipid soluble anesthetics of such widely different structures affect the ion... [Pg.44]

A gold chain driven by a synchronous motor passes over a coating block where the chain is wetted with the column eluent. The wetted chain then passes into an evaporator tunnel where the chain is heated and the solvent volatilized leaving any solute present in the eluent deposited on the chain. The chain passes out of the tunnel into the flame of an FID. During combustion of the solute, ions are produced in the expected manner and the ion current monitored by the detector electronics. Unfortunately, due to the occlusion of local, high concentrations of solute between the links of the chain, the detector output is extremely noisy and the overall system exhibits a relatively poor sensitivity. A chromatogram obtained with the chain detector is shown in figure 10. [Pg.288]

This quantity is independent of the surface profile and directly connected to the exchange frequencies oidep tink or diss,kink od can be considered as a system property giving a key to the kinetics of the metal ion transfer reaction. The local exchange current density as defined by eq. (2.23) is an imaginary quantity assuming a surface fully covered by kink sites. [Pg.27]

Other topical anesthetics can be delivered using iontophoresis—a therapy that uses a local electric current to introduce the ions of a medicine into the tissues—and anesthetic patch. [Pg.303]

Fig. 15 a Schematic principle showing the metal ion array on a graphite surface b and c show the results of the locally resolved current-induced tunneling spectroscopy (CITS) measurements of a [2 x 2] Co and [3 x 3] Mn indicating the position and arrangement of the respective metal ions. Adapted from [150]... [Pg.34]

It is necessary to exceed the critical anodic potential (23) bd for the electrochemical breakdown of passivation by pitting and consists of these factors (i) presence of halides at the interface (ii) induction time for the initiation of the breakdown process, leading to localized conditions that may increase the localized corrosion current density (iii) development of favorable conditions inside the pits for propagation when the local sites become immobile and localized at certain sites. Electrochemical breakdown of some metal oxides is possible in the case of copper, lead, and tin cathodically to metal while ferric oxide is reduced to the ferrous ion in aqueous solutions. Zinc and aluminum oxides are not cathodically reducible and in these cases hydrogen is reduced. The vigorous evolution of hydrogen assisted by electron conducting zinc oxide can accelerate the breakdown of passivity. [Pg.19]

Whereas auxiliary anodes need not be consumed in order to fulfill their purpose, sacrificial anodes are consumed not less than is required by Faraday s law in order to supply an equivalent electric current. In general, the observed rate of consumption is greater than the theoretical. For zinc the difference is not large, but for magnesium it is appreciable, with the cause being ascribed to local-action currents on the metal surface, to formation of colloidal metal particles [13, 14] or, perhaps more important, to initial formation of univalent magnesium ions [15], The latter ions are unstable and react in part with water in accord with... [Pg.259]

The identification of tobramycin and apramycin in samples from autopsy can be carried out by interfacing the TLC-sy stem to mass spectrometry (34). The extract (extraction with acetone/methanol [7 3]) and standard (0.5 mg/ml chloroform) are spotted in lOpl-quantities on silica gel plates, the spots of tobramycin are localized after separation in 30% aqueous ethanol, containing 2.5 M NaCl by spraying with a 3% NaOCl solution (/ /= 0.30). Apramycin is detected with Cd/12/starch (/ y= 0.45). For the modified Wick-Stick-technique the area of the spots is scraped from the plate, extracted with ethanol and the extract concentrated in the tip of a triangle-shaped prism pressed from NH4CI, after the prism had been immersed into the solution. After drying the tip was cut off powdered and introduced into the mass spectrometer (VG 7035, 20-70 eV electron energy, 500 iA ion current, 140 C source temperature, scan rate 0.5 s/decade while the probe temperature was raised fast to... [Pg.460]


See other pages where Local ion current is mentioned: [Pg.712]    [Pg.150]    [Pg.151]    [Pg.151]    [Pg.712]    [Pg.150]    [Pg.151]    [Pg.151]    [Pg.182]    [Pg.48]    [Pg.491]    [Pg.425]    [Pg.194]    [Pg.198]    [Pg.95]    [Pg.355]    [Pg.556]    [Pg.182]    [Pg.540]    [Pg.129]    [Pg.459]    [Pg.478]    [Pg.95]    [Pg.244]    [Pg.166]    [Pg.431]    [Pg.244]    [Pg.230]    [Pg.182]    [Pg.561]    [Pg.96]    [Pg.1598]    [Pg.1900]    [Pg.561]    [Pg.48]    [Pg.108]    [Pg.3]   
See also in sourсe #XX -- [ Pg.148 ]