Liquid chromatography MALDI

Zhang, N., Li, N. and Li, L. (2004a) Liquid chromatography MALDI MS/MS for membrane proteome... [Pg.380]

APCI, atmospheric pressure chemical ionization Cl, chemical ionization El, electron impact ESI, electrospray ionization FAB, fast atom bombardment GC, gas chromatography LC, liquid chromatography MALDI, matrix-assisted laser desorption ionization MS, mass spectrometry MS/MS, tandem mass spectrometry PAHs, polycyclic aromatic hydrocarbons PEG, polyethylene glycol PPG, polypropylene glycol. [Pg.2798]

The introduction and eventual commercialization of matrix-assisted laser desorption/ionization (MALDI) and electrospray (ESI) allowed biomarker status to be extended to proteins in 1996.15"17 With a few exceptions, ESI has been used in conjunction with extractions and high-pressure liquid chromatography (UPLC) interfaced with mass spectrometry. MALDI, on the other hand, has been widely adapted for rapid analysis of intact organisms, supported by bioinformatics.1819... [Pg.258]

Liquid chromatography (LC) encompasses several techniques, which includes HPLC and SEC (sometimes referred to as GPC). Many variants of and developments from these techniques exist, and are used in the study and analysis of polymer degradation/oxidation. As discussed earlier, SEC is often coupled with MALDI-ToF-MS to facilitate the identification of the products of polymer degradation. SEC has also been coupled with mid-infrared detection and similarly used for studies of polymer degradation. SEC/GPC is discussed further below. [Pg.443]

Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer... Figure 2.1 Mass spectrometric approach. Dl, direct inlet GC, gas chromatography HPLC, high performance liquid chromatography CZE, capillary zone electrophoresis El, electron ionization Cl, chemical ionization ESI, electrospray ionization DESI, desorption electrospray ionization APCI, atmospheric pressure chemical ionization MALDI, matrix assisted laser desorption ionization B, magnetic analyzer E, electrostatic analyzer...
The mass-selective instability mode of operation permits the selection and trapping of all ions created over a specified period with subsequent ejection to the detector.26 Ions with different m/z values can be confined within the ion trap and scanned singly by application of voltages that destabilize the orbits of the ions and eject them to the detector. Ion trap instruments interface readily with liquid chromatography, ESI,15 and MALDI.27 The motions of the ions and the dampening gas (e.g., helium) concentrate around the middle of the ion trap, thereby diminishing ion loss through collisions with electrodes. [Pg.382]

Atmospheric pressure ionization mass spectrometers, 13 468 Atmospheric pressure chemical ionization (APCI) liquid chromatography, 4 625 Atmospheric Pressure MALDI, 15 658 Atmospheric stability, of organic semiconductors, 22 210... [Pg.77]

Finke, B. Stahl, B. Pfenninger, A. Karas, M. Daniel, H. Sawatzki, G. Analysis of High-Molecular-Weight Oligosaccharides From Human Milk by Liquid Chromatography and MALDI-MS. Anal. Chem. 1999, 77,3755-3762. [Pg.436]

Nowadays, ESI is the leading member of the group of atmospheric pressure ionization (API) methods and the method of choice for liquid chromatography-mass spectrometry coupling (LC-MS, Chap. 12). [10-13] Currently, ESI and MALDI (Chap. 10) are the most commonly employed ionization methods and they opened doors to the widespread biological and biomedical application of mass spectrometry. [5,10,11,13-17] Moreover, ESI serves well for the analysis of ionic metal complexes [18,19] and other inorganic analytes. [20-22]... [Pg.441]

FAB and PD have been replaced by electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) in the analytical mass spectrometry laboratory, because both of these newer techniques have a wider mass range of analysis and have lower detection limits. ESI and MALDI have become invaluable ionization techniques for nonvolatile components. This is particularly true for a wide range of biological molecules including proteins, peptides, nucleic acids, etc. Samples can be analyzed by ESI using either direct injection or introduction through liquid chromatography. [Pg.204]


See other pages where Liquid chromatography MALDI is mentioned: [Pg.150]    [Pg.49]    [Pg.59]    [Pg.99]    [Pg.150]    [Pg.49]    [Pg.59]    [Pg.99]    [Pg.1030]    [Pg.128]    [Pg.129]    [Pg.239]    [Pg.185]    [Pg.29]    [Pg.105]    [Pg.181]    [Pg.240]    [Pg.370]    [Pg.571]    [Pg.398]    [Pg.45]    [Pg.162]    [Pg.551]    [Pg.63]    [Pg.680]    [Pg.769]    [Pg.73]    [Pg.117]    [Pg.166]    [Pg.324]    [Pg.875]    [Pg.4]    [Pg.236]    [Pg.77]    [Pg.128]    [Pg.139]    [Pg.210]    [Pg.114]    [Pg.12]    [Pg.32]    [Pg.416]    [Pg.241]    [Pg.4]   
See also in sourсe #XX -- [ Pg.221 , Pg.728 ]