Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Line regulation

Petroleum pipe hues before 1969 were built to ASA (now ANSI) Standard B31.4 for liquids and Standard B31.8 for gas. These standards were seldom mandatoiy because few states adopted them. The U.S. Department of Transportation (DOT), which now has responsi-bihty for pipe-line regulation, issued Title 49, Part 192—Transportation of Natural Gas and Other Gas by Pipeline Minimum Safety Standards, and Part 195—Transportation of Liquids by Pipehne. These contain considerable material from B31.4 and B31.8. They allow generally higher stresses than the ASME Pressure Vessel Code would allow for steels of comparable strength. The enforcement of their regulations is presently left to the states and is therefore somewhat uncertain. [Pg.1020]

Line regulation Percentage change in the output voltage(s) in response to a change in the input voltage. [Pg.7]

Operators also need to test flame failure controls, check the fuel delivery equipment (pumps, fuel lines, regulators, etc.), and keep adequate fuel consumption records. [Pg.121]

Eckmann, C., Jung, EEC., Schurer-Maly, C., Panja, A., Wroblewska, E.M. and Kagnoff, M. (1993) Differential cytokine expression by human intestinal epithelial cell lines regulated expression of IL-8. Gastroenterology 105, 1689-1697. [Pg.368]

Split vent. The sample vapors that do not enter the column are ejected through the split vent. A needle valve on this line regulates the total flow of carrier gas into and from the inlet, generating the split ratio, which determines the portion of sample that enters the column. The split ratio is the ratio of the split vent flow to the column flow and provides a measure of the amount of sample that actually enters the column from the injection. A split ratio of 100 1 indicates that a lpl injection from the syringe results in approximately 10 ml of liquid sample reaching the column. [Pg.463]

The prostaglandins produced by the COX enzyme have uses in the body in addition to their role in pain response, including maintaining the health of the stomach lining, regulating blood flow to the kidneys, and enabling specialized blood cells called platelets to initiate the process of blood clotting. Because the COX enzyme is responsible for all of these other functions, there are some potentially harmful side effects of NSAIDs, as will be discussed below. [Pg.24]

In-line service requires the use of an in-line regulator. This is any regulator without a CGA cylinder connection. The in-line regulators are used at any point needed in the hydrogen generating system to reduce system pressure. [Pg.67]

Most in-line regulators are single stage as there is usually not much pres-t- sure difference between inlet and outlet. In-line regulators connected to lim-... [Pg.68]

The only regulator used in this system is a line regulator rated for hydrogen. It is brass and thus has to be watched for corrosion. A better regulator would be nickel plated brass or stainless steel. Because this was an experimental unit destined only for seasonal work, this was not a particular issue with us. [Pg.83]

Line Regulator 0-30 psi Operating Pressure, 0-60 psi Gauge McMaster- Carr 7864A11 1... [Pg.222]

What does this tell us If the output of the buck-boost is independent of the input voltage, clearly we must have inherent line regulation. And it is for free ... [Pg.448]

So how did we manage to achieve automatic line regulation As the input voltage increases, the feedback loop of the regulated buck converter commands its duty cycle to decrease to maintain output regulation. It just so happens that this decrease in duty cycle is exactly what was required by the discontinuous mode buck-boost to regulate its own output almost perfectly. [Pg.448]

Determine which products of this description meet or exceed the requirements for line regulation, load r ulation, temperature coefficient of output voltage TC of Vo > and operating ambient temperature range. [Pg.1034]

Ripple rejection in decibels. This specihcation is for the line regulation, indicating the regulator s attenuation of the line voltage ripple. It is predicated on particular AC input signal levels and frequencies with a specified value of bypass capacitor. [Pg.1041]

Current mode control In this method, as shown in Fig. 10.79, a second inner control loop compares the peak inductor current with the control voltage, which provides improved open-loop line regulation. All of the problems of the direct duty cycle control method (1) and (2) are corrected with this method. An additional advantage of this method is that the two pole second-order filter is reduced to a single pole (the filter capacitor) first-order filter resulting in simpler compensation networks. There are several current mode control ICs available in the market. [Pg.1082]

DTI engineering inspectors the notification of specified events (such as death caused by systems covered by the Regulations) and certain interruptions of supply exemptions from the Regulations breaches and offences and the revocation of the previous Electricity Supply Regulations and the Electricity (Overhead Lines) Regulations 1970. [Pg.118]

Kiss, H., Schneeberger, C., Tschugguel, W., Lass, H., Huber, J.C., Husslein, R, and Knofler, M. (1998). Expression of endothelial (type 111) nitric oxide synthase in cytotrophoblastic cell lines regulation by hypoxia and inflammatory cytokines. Rlacenta 79(8), 603-611. [Pg.36]


See other pages where Line regulation is mentioned: [Pg.622]    [Pg.185]    [Pg.44]    [Pg.305]    [Pg.305]    [Pg.220]    [Pg.5]    [Pg.185]    [Pg.469]    [Pg.159]    [Pg.33]    [Pg.207]    [Pg.193]    [Pg.364]    [Pg.132]    [Pg.1082]    [Pg.513]    [Pg.521]    [Pg.533]    [Pg.107]    [Pg.111]    [Pg.228]    [Pg.85]    [Pg.89]   
See also in sourсe #XX -- [ Pg.5 , Pg.448 ]




SEARCH



Lines system voltage regulation

© 2024 chempedia.info