Leakage testing

Fig. 1. Schematic of magnetic flux leakage tests where H,B represents an external appHed magnetic field. See text, (a) Saturated material having no crack,... Fig. 1. Schematic of magnetic flux leakage tests where H,B represents an external appHed magnetic field. See text, (a) Saturated material having no crack,...
Tlie indi ddual cells are assembled into batteries after a leakage test to check for faulty welding joints in steel containers or cracks and improper seals in the plastic encased cells. Cells that are to be delivered without electroltye are emptied after the fomiation cycles. Tlie steel-cased cells hav e to be separated by mechanical means to prevent intercell shorts and are often assembled into wooden crates. Tlie cells in plastic cases can be cemented together or strapped with tape. [Pg.547]

Fig. 6. Temperature—humidity—bias leakage testing of encapsulants at 85°C, 85% rh, and 180 V bias. Fig. 6. Temperature—humidity—bias leakage testing of encapsulants at 85°C, 85% rh, and 180 V bias.
Watertightness and air leakage test for isolated phase bus systems. [Pg.954]

Dry face seal leakage test under static and dynamic conditions... [Pg.341]

Dry Face Seal Leakage Test Under Static and Dynamic Conditions... [Pg.347]

HEPA filters consist of a filter pack sealed into a case. The filter pack or core is made by pleating a continuous web of fiberglass paper back and forth over corrugated separators. The filter pack is sealed into a full-depth wood or steel casing using a elastomeric sealant. Gasketing is a critical item to ensure that the filter passes the air leakage tests. [Pg.1243]

The question of relative rates of seal leakage and permeation (cf. points 1 and 3) has been considered by MERE. For the sealing of HPHT (5000 psi, ca. 345 bar, or 34.5 MPa 100°C) fluids with chevron seal-stack systems used at the bottom of oil wells in intermittently dynamic conditions, high-pressure permeation and seal-leakage tests using the equipment outlined in Section 23.3.1.2 have been conducted it has been shown that methane gas permeation rate was only ca. 1 % of the rate... [Pg.633]

Leakage testing must be done with 30 second or one minute smoke candles placed approximately 20 centimeters inside the hood. Any visible escape of smoke should be considered indicative of unacceptable performance. [Pg.222]

M. Bram et al., Deformation Behavior and Leakage Tests of Alternate Sealing Materials for SOFC Stacks, Journal of Power Sources, 138, pp. 111-119 (2004). [Pg.236]

Magnetic flux density, 15 434 exponents of dimensions, 8 585t Magnetic flux leakage tests, 17 419-420 Magnetic flux leakage technique, in... [Pg.544]

As a result of KU s know-how in this field, the guaranteed shutdown period for converting a 340 000 metric tonne per year NaOH plant from mercury to membrane technology was as short as 8 weeks. This was made possible by a new conversion concept the individual elements were assembled in an adjoining assembly hall and installed in cell racks of 72 elements each. In this way, more than 2600 elements were assembled and installed in 18 two-rack electrolysers, and pressure and leakage tested. As soon as part of the mercury electrolysis plant was dismantled, the completed electrolysers were placed onto the vacated area and connected to the piping already installed beneath the cell rows (Fig. 16.6). [Pg.215]

Leak test pressure The specified inlet static pressure at which a quantitative seat leakage test is performed in accordance with a standard procedure (e.g. API 527, see Section 4.2). [Pg.40]

An in vitro compatibility study ( leakage test ) had been performed beforehand ... [Pg.713]

Leakage test for ampules, vials, sachets, aerosols, strips, tubes, and so... [Pg.207]

Leakage Test This test is mandatory for ophthalmic ointments, which evaluates the intactness of the ointment tube and its seal. Ten sealed containers are selected, and their exterior surfaces are cleaned.They are horizontally placed over absorbent blotting paper and maintained at 60 3 °C for 8 h. The test passes if leakage is not observed from any tube. If leakage is observed, the test is repeated with an additional 20 tubes. The test passes if not more than 1 tube shows leakage out of 30 tubes [15]. [Pg.284]

Filter leakage tests (To verify filter integrity) All classes 24 months Filter penetration tests to be carried out by a recognized authority to demonstrate filter media and filter seal integrity. Only required on HEPA filters. In accordance with ISO 14644-3 Annex B6 ... [Pg.83]


See other pages where Leakage testing is mentioned: [Pg.988]    [Pg.953]    [Pg.957]    [Pg.340]    [Pg.249]    [Pg.213]    [Pg.231]    [Pg.76]    [Pg.76]    [Pg.185]    [Pg.185]    [Pg.186]    [Pg.187]    [Pg.351]    [Pg.361]    [Pg.369]    [Pg.47]    [Pg.250]    [Pg.299]    [Pg.605]    [Pg.73]    [Pg.223]    [Pg.249]    [Pg.2138]    [Pg.155]    [Pg.176]    [Pg.194]   