Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Laser desorption/ionization porous silicon

Laiko, V.V. Taranenko, N.I. Berkout, V.D. Musselman, B.D. Doroshenko, V.M. Atmospheric Pressure Laser Desorption/Ionization on Porous Silicon. Rapid Commun. Mass Spectrom. 2002,16, 1737-1742. [Pg.440]

Shen, Z., Thomas, J.J., Averbuj, C., Broo, K.M., Engelhard, M., Crowell, J.E., Einn, M.G., Siuzdak, G. Porous silicon as a versatile platform for laser desorption/ionization mass spectrometry. Anal. Chem. 2001, 73, 612-619. [Pg.300]

Matrix-free direct laser desorption ionization of analyte has been studied on different kinds of surfaces without real success because degradation of the sample is usually observed. However, good results were obtained with the method called surface-activated laser desorption ionization (SALDI) [43] which uses graphite as the surface. But the use of porous silicon as a new surface is more promising and has led to the development of a new method called desorption ionization on silicon (DIOS) [44], Unlike the other matrix-free laser desorption ionization methods, DIOS allows ion formation from analyte with little or no degradation. [Pg.38]

Desorption/ionization on silicon. Another matrix-free approach for the analysis of small molecules is to use modified porous silicon surfaces [61]. A separate name, desorption/ionization on silicon (DIOS), has been coined for this technique [62]. In this approach, the sample is dispensed directly onto a modified porous silicon surface (e.g., silylated porous silicon) and laser-desorbed from the surface. The silicon surface is prepared from flat crystalline silicon by galvanostatic etching. [Pg.43]

Lowe RD, Szili EJ, Kirkbride P, Thissen H, Siuzdak G, Voelcker NH (2010) Combined immunocapture and laser desorption/ionization mass spectrometry on porous silicon. Anal Chem 82 4201-4208... [Pg.86]

Arakawa R, Shimomae Y, Morikawa H, Ohara K, Okuno S (2004) Mass spectrometric analysis of low molecular mass polyesters by laser desorption/ionization on porous silicon. J Mass Spectrom JMS 39 961-965... [Pg.677]

Shmigol IV, Alekseev SA, Lavrynenko OY, Vasylieva NS, Zaitsev VN, Barbier D, Pokrovsky VA (2009) Chemically modified porous silicon for laser desorption/ionization mass spectrometry of ionic dyes. J Mass Spectrom JMS 44 1234—1240... [Pg.679]

Xu S, Pan C, Hu L, Zhang Y, Guo Z, Li X, Zou H (2004) Enz5maatic reaction of the immobilized enzyme on porous silicon studied by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry. Electrophoresis 25 3669-3676... [Pg.680]

Xu S, Zhou H, Pan C, Fu Y, Zhang Y, Li X, Ye M, Zou H (2006) Iminodiacetic acid derivatized porous silicon as a matrix support for sample pretreatment and matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry analysis. Rapid Commun Mass Spectrom 20 1769-1775... [Pg.680]

Kauppila TJ, Talaty N, Salo PK, Kotiaho T, Kostiainen R, Cooks RG (2006) New surfaces for desorption electrospray ionization mass spectrometry porous silicon and ultra-thin layer chromatography plates. Rapid Commun Mass Spectrom 20 2143-2150 Kebarle P, Tang L (1993) From ions in solution to ions in the gas phase - the mechanisms of electrospray mass spectrometry. Anal Chem 65 972A-986A Laiko W, Taranenko NI, Berkout VD, Musselman BD, Doroshenko VM (2002) Atmospheric pressure laser desorption/ionization on porous silicon. Rapid Commun Mass Spectrom 16 1737-1742... [Pg.777]

Law KP (2010) Laser desorption/ionization mass spectrometry on nanostructured semiconductor substrates DIOS (TM) and QuickMass (TM). Int J Mass Spectrom 290 72-84 Law KP, Larkin JR (2011) Recent advances in SALDI-MS techniques and their chemical and bioanalytical applications. Anal Bioanal Chem 399 2597-2622 Lewis WG, Shen Z, Finn MG, Siuzdak G (2003) Desorption/ionization on silicon (DIOS) mass spectrometry background and applications. Int J Mass Spectrom 226 107-116 Li Q, Alonso R, Renner SA, Winefordner JD, Powell DH (2005) Desorption/ionization on porous silicon mass spectrometry studies on pentose-borate complexes. Anal Chem 77 4503-4508 Lin Z, Zhang S, Zhao M, Yang C, Chen D, Zhang X (2008) Rapid screening of clenbuterol in urine samples by desorption electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom 22 1882-1888... [Pg.777]

Lowe RD, Guild GE, Harpas P, Kirkbride P, Hoffmann P, Voelcker NH, Kobus H (2009) Rapid drug detection in oral samples by porous silicon assisted laser desorption/ionization mass spectrometry. Rapid Commun Mass Spectrom 23 3543-3548 Lowe RD, Szili EJ, Kirkbride P, Thissen H, Siuzdak G, Voelcker NH (2010) Combined immunocapture and laser desorption/ionization mass spectrometry on porous silicon. Anal Chem 82 4201-4208... [Pg.777]

Okuno S, Nakano M, Matsubayashi GE, Arakawa R, Wada Y (2004) Reduction of organic dyes in matrix-assisted laser desorption/ionization and desorption/ionization on porous silicon. Rapid Commun Mass Spectrom 18 2811-2817... [Pg.778]

Lowe, R. D., G. E. Guild, P. Harpas, P. Kirkbride, P. Hoffmann, N. H. Voelcker, and H. Kobus. 2009. Rapid drug deteetion in oral samples by porous silicon assisted laser desorption/ionization mass speetrometry. RapidCommun. Mass Spectrom. 23 3543—3548. [Pg.331]

G. Porous silicon as a versatile platform for laser desorption/ionization mass spectrometry. Anal. Chem. 2001, 73, 612-619. [Pg.213]

Figure 7.5. Experimental configuration for the DIOS-MS experiments, (a) Four porous silicon plates are placed on a MALDI plate. Each of the porous silicon plates contains photopattemed spots or grids prepared through illumination of -type silicon with a 300-S tungsten filament through a mask and an 50 reducing lens, (b) Ibe silicon-based laser desorption/ionization process, in which the sample is placed on the porous silicon plate and allowed to dry, followed by laser-induced desorption/ionization mass spectrometry, (c) Cross section of porous silicon, and the surface functionalities after hydrosilylation R represents phenyl or alkyl chains. (Reproduced with permission from Wei, J. Buriak, J. Siuzdak, G. Desorption/ionization mass spectrometry on porous silicon. Nature 1999, 399, 243-246.)... Figure 7.5. Experimental configuration for the DIOS-MS experiments, (a) Four porous silicon plates are placed on a MALDI plate. Each of the porous silicon plates contains photopattemed spots or grids prepared through illumination of -type silicon with a 300-S tungsten filament through a mask and an 50 reducing lens, (b) Ibe silicon-based laser desorption/ionization process, in which the sample is placed on the porous silicon plate and allowed to dry, followed by laser-induced desorption/ionization mass spectrometry, (c) Cross section of porous silicon, and the surface functionalities after hydrosilylation R represents phenyl or alkyl chains. (Reproduced with permission from Wei, J. Buriak, J. Siuzdak, G. Desorption/ionization mass spectrometry on porous silicon. Nature 1999, 399, 243-246.)...
Kruse, R. Rubakhin, S. Romanova, E. Hohn, P. Sweedler, j. Direct assay of Aplysia tissues and cells with laser desorption/ionization mass spectrometry on porous silicon. JAfass Spectrom. 2001,36,1317-1322. [Pg.243]

Laiko, V. V Taranenko, N. I. Berkout, V. D. Musselman, B. D. Doroshenko, V. M. Atmospheric pressure laser desorption/ionization on porous silicon. [Pg.339]


See other pages where Laser desorption/ionization porous silicon is mentioned: [Pg.6]    [Pg.116]    [Pg.290]    [Pg.556]    [Pg.345]    [Pg.411]    [Pg.38]    [Pg.541]    [Pg.543]    [Pg.55]    [Pg.1480]    [Pg.3]    [Pg.374]    [Pg.674]    [Pg.674]    [Pg.679]    [Pg.777]    [Pg.779]    [Pg.779]    [Pg.78]    [Pg.119]    [Pg.199]    [Pg.291]   
See also in sourсe #XX -- [ Pg.237 ]




SEARCH



Desorption ionization

Laser desorption

Laser ionization

Laser ionizing

Silicon porous

© 2024 chempedia.info