Laser ablation comparisons

Fullerenes are described in detail in Chapter 2 and therefore only a brief outline of their structure is presented here to provide a comparison with the other forms of carbon. The C o molecule, Buckminsterfullerene, was discovered in the mass spectrum of laser-ablated graphite in 1985 [37] and crystals of C o were fust isolated from soot formed from graphite arc electrodes in 1990 [38]. Although these events are relatively recent, the C o molecule has become one of the most widely-recognised molecular structures in science and in 1996 the codiscoverers Curl, Kroto and Smalley were awarded the Nobel prize for chemistry. Part of the appeal of this molecule lies in its beautiful icosahedral symmetry - a truncated icosahedron, or a molecular soccer ball, Fig. 4A. [Pg.9]

Poitrasson, X.L., Mao, S.S., Freydier, R., Russo, R.E. 2003. Comparison of ultraviolet femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry analysis in glass, monazite, and zircon. Analytical Chemistry, 75, 6184-6190. [Pg.298]

Young ED, Ash RD, Galy A, Belshaw NS (2002) Mg isotope heterogeneity in the Allende meteorite measured by UV laser ablation-MC-ICPMS and comparisons with O isotopes. Geochim Cosmochim Acta 66 683-698... [Pg.64]

Jackson SE, Gunther D (2003) The nature and sources of laser induced isotopic fractionation in laser ablation-multicollector-inductively coupled plasma-mass spectrometry. J Anal At Spectrom 18 205-212 Jiang S-J, Houk RS, Stevens MA (1988) Alleviation of overlap interferences for determination of potassium isotope ratios by Inductively-Coupled Plasma Mass Spectrometry. Anal Chem 60 1217-1220 Lam JWH, Horlick G (1990) A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry. Spectrochim Acta Part B 45 1313-1325 Langmuir I, Kingdon KH(1925) Thermionic effects caused by vapours of alkali metals. Phil Trans R Soc A107 61-79... [Pg.148]

Table 4. Tabulation of A Mg vs. A O for various chondrite components. A O laser ablation data are shown explicitly to demonstrate that averages are reflective of the bulk objects. Where data are few, the objects are small in comparison to laser beam diameter. Table 4. Tabulation of A Mg vs. A O for various chondrite components. A O laser ablation data are shown explicitly to demonstrate that averages are reflective of the bulk objects. Where data are few, the objects are small in comparison to laser beam diameter.
Calibration and quantification procedures are easier in LA-ICP-MS compared to other solid-state mass spectrometric techniques because the laser ablation and the ICP ion source operate at normal pressure and the laser ablation of solid samples and ionization of analytes are separated in space and time. Therefore the advantage of solution calibration in ICP-MS can be applied in this solid-state analytical technique. The introduction of solution based calibration, which is only possible in LA-ICP-MS, was an innovative step in the development of this sensitive mass spectrometric technique. A number of different calibration approaches using aqueous standard solutions in the dual gas flow technique have been discussed by various authors.74 75 In the dual gas flow injection technique , the nebulized standard solution and the laser ablated sample material are mixed in the -piece and the two gas flows from the nebulizer (e.g. ultrasonic nebulizer) and laser ablation chamber are added. Using solution based calibration with the addition of a standard solution, Leach et alP determined minor elements in steel reference materials with a relative accuracy of a few %. In comparison to the so-called dual gas flow technique proposed in the literature, where the argon flow rates through the nebulizer and ablation cell add up to 11 min-1 (e.g. 0.451 min-1 and... [Pg.201]

On line additions of aqueous standard solutions for the calibration of LA-ICP-MS including a comparison of wet and dry plasma conditions are discussed by O Connor et al.ls For solution calibration of standard solutions the authors used a 100 (xl PFA nebulizer together with a cyclonic spray chamber or a MCN-6000 sample introduction system with desolvator, to study the wet and dry plasma, respectively. A polypropylene Y piece was applied to mix the laser ablated material and the nebulized standard solutions. The authors found that the on line addition of water is the preferred mode of operation for quantification by LA-ICP-MS, i.e., wet plasma is more stable (improved standard deviation of sensitivity ratios). [Pg.204]

Use of inductively coupled plasma-mass spectrometry (1CP-MS) coupled to a laser-ablation sample introduction system (LA-ICP-MS) as a minimally destructive method for chemical characterization of archaeological materials has gained favor during the past few years. Although still a relatively new analytical technique in archaeology, LA-ICP-MS has been demonstrated to be a productive avenue of research for chemical characterization of obsidian, chert, pottery, painted and glazed surfaces, and human bone and teeth. Archaeological applications of LA-ICP-MS and comparisons with other analytical methods are described. [Pg.275]

Gholap D, Izmer A, Samber B, van Elteren J, Selih V, Evens R, Schamphelaere K, Janssen C, Balcaen L, Lindemann I, Vincze L, Vanhaecke F (2010) Comparison of laser ablation-induc-tively coupled plasma-mass spectrometry and micro-X-ray fluorescence spectrometry for elemental imaging. Anal Chim Acta 664 19-26. doi 10.1016/j.aca.2010.01.052... [Pg.419]

Combustion of coal produces ash that can be transported through the air. Slagging and fouling problems can also be predicted from elemental analysis. Therefore, elemental analysis of both the coal as well as the ash are important. Procedures for dissolution and analysis of coal and combustion products of coal have been reported [334-336]. Laser ablation sampling has been successfully used for coal and combusted materials [337,338]. The direct introduction of slurries has also been used [339]. Comparison of ICP-MS and PIXE analysis of coal combustion aerosols showed that analysis errors can occur in ICP-MS if particle vaporization is incomplete in the ICP [340]. [Pg.135]

Table 2 Comparison of Isotopic Compositions Measured by Laser Ablation Multiple-Collector Inductively Coupled Plasma Mass Spectrometry and Those Measured by Other Methods... Table 2 Comparison of Isotopic Compositions Measured by Laser Ablation Multiple-Collector Inductively Coupled Plasma Mass Spectrometry and Those Measured by Other Methods...

See other pages where Laser ablation comparisons is mentioned: [Pg.112]    [Pg.531]    [Pg.144]    [Pg.408]    [Pg.441]    [Pg.55]    [Pg.369]    [Pg.135]    [Pg.201]    [Pg.209]    [Pg.406]    [Pg.611]    [Pg.40]    [Pg.204]    [Pg.7]    [Pg.5]    [Pg.43]    [Pg.151]    [Pg.152]    [Pg.349]    [Pg.362]    [Pg.428]    [Pg.108]    [Pg.347]    [Pg.321]    [Pg.321]    [Pg.338]    [Pg.5]    [Pg.43]    [Pg.151]    [Pg.152]    [Pg.201]    [Pg.349]    [Pg.362]    [Pg.428]   
See also in sourсe #XX -- [ Pg.456 , Pg.457 , Pg.458 , Pg.459 ]