The proposal that PVAc also has non-hydrolyzable long chain branches stems from the finding that PVA also possesses long chain branches. No/akura et a/.171 "07 suggested, on the basis of kinetic measurements coupled with chemical analysis, that chain transfer to PVAc involves preferential abstraction of backbone (methine) hydrogens (ca 5 1 v,v the acetate methyl hydrogens at 60 °C). [Pg.324]

Almost all kinetic investigations on azo coupling reactions have been made using spectrophotometric methods in very dilute solutions. Uelich et al. (1990) introduced the method of direct injective enthalpimetry for such kinetic measurements. This method is based on the analysis of the zero-current potential-time curves obtained by the use of a gold indicator electrode with a surface which is periodically restored (Dlask, 1984). The method can be used for reactions in high (industrial) concentrations. [Pg.354]

Direct kinetic measurements from the changes in diffracted beam intensities with time during heating of the reactant are illustrated in the work of Haber et al. [255]. Gam [126] has reviewed the apparatus used to obtain X-ray diffraction measurements in thermal analysis. Wiedemann [256] has designed equipment capable of giving simultaneous thermo-gravimetric and X-ray data under high vacuum. X-Ray diffraction studies enable the presence, or absence, of topotactic relationships between reactant and product to be detected [92,102,257—260], Results are sometimes considered with reference to the pseudomorphic shape of residual crystallites. [Pg.27]

The concentration of the transferred ion in organic solution inside the pore can become much higher than its concentration in the bulk aqueous phase [15]. (This is likely to happen if r <5c d.) In this case, the transferred ion may react with an oppositely charged ion from the supporting electrolyte to form a precipitate that can plug the microhole. This may be one of the reasons why steady-state measurements at the microhole-supported ITIES are typically not very accurate and reproducible [16]. Another problem with microhole voltammetry is that the exact location of the interface within the hole is unknown. The uncertainty of and 4, values affects the reliability of the evaluation of the formal transfer potential from Eq. (5). The latter value is essential for the quantitative analysis of IT kinetics [17]. Because of the above problems no quantitative kinetic measurements employing microhole ITIES have been reported to date and the theory for kinetically controlled CT reactions has yet to be developed. [Pg.383]

Such techniques imply analysis of chemical products of photolysis. Application of mass-spectrometers of various types is often hampered by a number of circumstances. These difficulties will be discussed later on. The EPR method, which is currently the most extensively employed technique, features low sensitivity and is usually used for analysis of primary fragments of photolysis. For this purpose, the radicals produced are frozen on the walls of a quartz pin and are thus accumulated inside the device. On one hand, this approach allows one to overcome the sensitivity threshold of the device. However, on the other hand, this excludes the possibility of direct kinetic measurements. The SS technique permits the use of weak light sources for detecting active particles under... [Pg.226]

Gas-phase Kinetics. A better appreciation of the experiments to be discussed later will be obtained after a review of some experimental aspects of the transient method. Here we deal with experiments at atmospheric pressure. A flow sheet for kinetic measurements is given in Fig. 1, a descendant of that first given by Bennett et al. (15). Chemical analysis of the gases during transients is ideally done by a mass spectrometer, although Kobayashi and Kobayashi (4 ) used a number of gas chromatographs in order to get samples sufficiently frequently. [Pg.2]

In addition, careful kinetic measurements and product analysis has revealed that the activation of the catalyst precursor 26b during the induction period occurs by hydrogenation of the coordinated maleic anhydride to succinic anhy-... [Pg.389]

Most of the techniques discussed above are typically used ex situ for catalyst characterization before and after reaction. This is normally the easiest way to carry out the experiments, and is often sufficient to acquire the required information. However, it is known that the reaction environment plays an important role in determining the structure and properties of working catalysts. Consequently, it is desirable to also try to perform catalytic studies under realistic conditions, either in situ [113,114,157, 191-193] or in the so-called operando mode, with simultaneous kinetics measurements [194-196], In addition, advances in high-throughput (also known as combinatorial) catalysis call for the fast and simultaneous analysis of a large number of catalytic samples [197,198], This represents a new direction for further research. [Pg.27]

To conclude, kinetic measurements and structural analysis of the copolymers have allowed a quantitative and self-consistent description of the reaction of RCI Li species on PMMA taking into account PMMA chain reactivity through the simplified model of the nearest neighbouring group effects. Two main features are particularly relevant the definite influence of tacticity, and the independance of the reaction process on the total charge of the copolymer. In this sense, the R-C Li/PMMA systems are closed to the PMMA basic hydrolysis in presence of excess base. (29,31). [Pg.127]

Recently, the steady-state reaction kinetics of CO oxidation at high pressure over Ru , Rh " , Pt, Pd, and Ir single crystals have been studied in our laboratory. These studies have convincingly demonstrated the applicability and advantages of model single crystal studies, which combine UHV surface analysis techniques with high pressure kinetic measurements, in the elucidation of reaction mechanisms over supported catalysts. [Pg.162]

Detailed kinetic measurements and kinetic analysis (by dynamic modeling) of chymotrypsin-containing POPC vesicles. [Pg.220]

A time-of-flight spectrometer can be used as a mass analyzer, an ion kinetic energy analyzer, and an ion reaction time analyzer. We will consider here only what factors affect the resolution of the system in mass analysis.74 The same consideration can easily be extended to find the resolution in other analyses. There are at least two kinds of mass resolution. One refers to the ability of the system to separate two ion species of nearly equal masses in the same mass spectrum. This is related to the sharpness of the mass lines, or the full width at half maximum (FWHM) of the mass lines. The other refers to the ability of the system to distinguish two ion species of nearly identical masses, but not necessarily in the same mass spectrum. This latter mass resolution is related to the sharpness of reference points in the mass lines such as the onset flight times of the ion species, and the overall long-term stability of the system. This latter resolution determined also how accurately the instrument can measure the mass of ion species. Although this latter resolution is more closely related to ion kinetic energy analysis and is as important as the former one, we will consider here only the former kind, or the conventional kind, of mass resolution. [Pg.147]

In the present study we investigated energy transfer between the Zn-porphyrin units in a sequence of dendrimers varying in size from 4 to 64 porphyrin units (Fig. 1). Reference measurements were performed on the monomer, P1D1. In order to follow energy transfer within the dendrimers, the fluorescence anisotropy decay were analysed. To determine the lifetime of the dendrimers, additional analysis of the kinetics measured at magic angle was performed. The fluorescence anisotropy is defined by... [Pg.495]


See other pages where Kinetic measurements, analysis is mentioned: [Pg.70]    [Pg.1014]    [Pg.70]    [Pg.1014]    [Pg.634]    [Pg.17]    [Pg.99]    [Pg.140]    [Pg.384]    [Pg.211]    [Pg.444]    [Pg.519]    [Pg.379]    [Pg.272]    [Pg.267]    [Pg.452]    [Pg.145]    [Pg.81]    [Pg.257]    [Pg.3]    [Pg.222]    [Pg.64]    [Pg.204]    [Pg.219]    [Pg.160]    [Pg.181]    [Pg.215]    [Pg.220]    [Pg.335]    [Pg.355]    [Pg.186]    [Pg.702]    [Pg.508]    [Pg.143]    [Pg.144]    [Pg.203]    [Pg.702]    [Pg.723]    [Pg.475]   