Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Interruption effects

The double bond functions in a very analogous manner. It too interrupts effective chain length and determines the principal point of oxidative attack. In a manner quite analogous to the methyl group, through changes in the combustion velocity, the double bond also alters the octane number and critical compression ratio. [Pg.371]

Case 4 represents the deteriorated condition of Case 3 caused by stress cracking from differential thermal expansion of the large, single-thickness blocks that interrupts effective heat transfer through the carbon and thermal degradation of the ramming layer between the ceramic and the carbon. [Pg.213]

In any case, I eventually recovered (and so did Jerry), but my immune system must have suffered serious damage, which manifested itself three years later, when I collapsed in my office one day and was found to be bleeding internally from a form of rare stomach cancer, which necessitated major surgery but was fortunately localized. I again recovered and have had no further difficulties since. Whether weakening and knocking out my immune system to overcome the previous problems had any effect is not clear, but it could have been a factor. Despite my health problems I was able to continue my work without much interruption, and the scientific productivity of my group has not... [Pg.117]

Despite the use of explosion-pressure-resistant equipment for the full explosion pressure or other design measures outlined later, everything possible must be done to prevent effective ignition sources, because loss of product and interruption of production are equally undesirable. [Pg.2326]

It is for the user to choose the most appropriate circuit breaker to suit requirements, application and cost. Here we discuss briefly the philosophy of circuit interruption and the effect of insulating and quenching mediums on the arc extinction of these breakers. We also deal briefly with the constructional features and application of such breakers. For more details one may refer to the manufacturers catalogues and literature available on the subject. [Pg.629]

Interrupting fault currents that are mostly inductive (Section 13.4.1) and occur at very low power factors. They are excessive in magnitude, and cause high thermal effects and electromagnetic forces on the arc chamber, the contacts and the contact mounting supports. [Pg.632]

Similarly, at lower currents, the volume of arc plasma is loo small I ) and so is the clogging effect. The pressure and volume of the quenching gas can be adjusted to interrupt the current now also at current zero. All these adjustments are pre-set and sealed by the manu-facturer. [Pg.641]

Figure 19.27 Approximate representation of assumed voltage and current waveforms illustrating a current-chopping effect and its attenuation while interrupting a circuit having 0,3 p.f. Figure 19.27 Approximate representation of assumed voltage and current waveforms illustrating a current-chopping effect and its attenuation while interrupting a circuit having 0,3 p.f.
The impact of Ice Storm 98 can clearly be seen by realizing that the number of customer interruptions and the customer hours of interruption for all of Canada in 1997 were 24,280,244 and 38,130,783, respectively. The ice storm alone resulted in 12,332,950 customer interruptions and 282,576,829 customer hours of interruption in the utilities affected. Removing the ice storm incidents from the 1998 Canada-wide data results in a SAIFI of 2.46 and a SAIDI of 3.40. The lOR is 99.9612 percent. Ice Storm 98 had only a relatively moderate effect on SAIFI but a dominant effect on the customer hours of interruption and the SAIDI statistic due to the extremely long storm duration and the required restoration period. It is important to realize that the bulk transmission system retained its integrity according to NERC criteria, and the impact of the ice storm on Ontario Hydro facilities did not propagate into neighboring interconnected utilities. [Pg.427]

The proof of protection is more difficult to establish in this case for two reasons. First, the object is to restore passivity to the rebar and not to render it virtually immune to corrosion. Second, it is difficult to measure the true electrode potential of rebars under these conditions. This is because the cathodic-protection current flowing through the concrete produces a voltage error in the measurements made (see below). For this reason it has been found convenient to use a potential decay technique to assess protection rather than a direct potential measurement. Thus a 100 mV decay of polarisation in 4 h once current has been interrupted has been adopted as the criterion for adequate protection. It will be seen that this proposal does not differ substantially from the decay criterion included in Table 10.3 and recommended by NACE for assessing the full protection of steel in other environments. Of course, in this case the cathodic polarisation is intended to inhibit pit growth and restore passivity, not to establish effective immunity. [Pg.123]

In certain tests it is sometimes desirable to eliminate any effects of a mechanically achieved surface condition by chemical treatment or pickling of the surface prior to test. This may be done in a pickling solution alternatively, the test itself may be interrupted after sufficient corrosion has occurred to remove the original surface, the specimen then being cleaned and reweighed and the test started over again. Wesley found it to be desirable to pickle off about 0-008 mm from the surface of specimens in acid to improve the reproducibility of the tests. [Pg.980]

The extent of galvanic action in atmospheric exposure may also be restricted by the development of corrosion products of high electrical resistance between the contacting surfaces — this is especially likely to occur if one of the metals in the couple is an iron or steel that will rust. In long-time tests such possible interruptions in the galvanic circuit should be checked by resistance measurements from time to time so as to determine the actual periods in which galvanic effects could operate. [Pg.1071]


See other pages where Interruption effects is mentioned: [Pg.285]    [Pg.55]    [Pg.977]    [Pg.124]    [Pg.216]    [Pg.285]    [Pg.55]    [Pg.977]    [Pg.124]    [Pg.216]    [Pg.45]    [Pg.19]    [Pg.59]    [Pg.1008]    [Pg.75]    [Pg.133]    [Pg.354]    [Pg.570]    [Pg.570]    [Pg.574]    [Pg.576]    [Pg.631]    [Pg.632]    [Pg.634]    [Pg.634]    [Pg.665]    [Pg.730]    [Pg.850]    [Pg.235]    [Pg.385]    [Pg.67]    [Pg.885]    [Pg.428]    [Pg.4]    [Pg.125]    [Pg.143]    [Pg.122]    [Pg.540]    [Pg.320]    [Pg.125]    [Pg.212]   
See also in sourсe #XX -- [ Pg.300 , Pg.301 , Pg.302 , Pg.303 , Pg.304 , Pg.305 , Pg.306 , Pg.307 , Pg.308 ]




SEARCH



Effect of -Conjugation and Interruption

Interruptions

Periodic flow interruption in trickle-bed cycle split effects

© 2024 chempedia.info