Thermal inspection methods

X-ray residual stress determination was performed on the surface of the samples prepared by HIP sintering. The measured residual stress was compared with the results calculated by the finite element method (FEM). The electrical resistivity was measured by the four probes method on the slices cut from the cylinder samples. In order to inspect the thermal stability, the samples were annealed at 900 °C for 24 hour in vacuum. The microstructure on the section was observed by scanning electron microscope. [Pg.600]

General corrosion control, prevention, and monitoring should be planned for from the onset. To detect and monitor corrosion, various methods must be used, while corrosion protection would be done by the addition of inhibition and use of protection coatings [5]. Visual examination, laser methods, the replication microscopy liquid penetration testing method, magnetic particles testing, the eddy current inspection method, acoustic emission technique, thermal methods of inspection, and nondestructive methods are the various methods to be adopted when monitoring pipeline corrosion [5]. [Pg.658]

However, it appears that none of the non-destructive tests currently employed directly correlate with any critical failure property. Most industrial test techniques such as through-transmission and pulse-echo ultrasonics, sonic vibration techniques. X-ray radiography, thermal inspection methods, holography, liquid penetrants, etc. basically attempt to find defects in the joint. Such defects may arise from several sources. Some defects arise from porosity, cracks or voids in the adhesive layer or at the interface and are typically filled with air they will simply be referred to as voids in the present discussions. However, during the service life of the joint such voids may fill with water which makes them far more difficult to detect since, for example, water has a much higher acoustic, impedance than air. Also, zero-volume voids, or debonds, may occur when the adhesive and substrate are in contact but no... [Pg.250]

There are a number of thermal inspection methods based upon variations in thermal conductivity, thermal emissivity or thermal capacity and the most important are the infrared and liquid crystal methods. Although, in theory, such techniques will detect changes in the thickness and density of the adhesive layer, in practice they detect changes in the above properties that arise from the presence of relatively large voids. [Pg.255]

A new design of an old concept of thermal surface inspection permits the photothermal camera to be considered as an interesting alternative to NDT methods like penetrant or magnetic testing, particularly when the testing has to be made in a remote or automatic way. [Pg.398]

Other NDE Methods The following methods also have applications magnetic field testing, microwave inspection, thermal inspection, and holography. [Pg.168]

Recall that semiempirical methods were parameterized in such a way that the computed electronic energies were equated with heats of formation, not computed enthalpies. Thus, when a semiempirical electronic structure program reports a 298 K heat of formation for AMI, for instance, the reported value derives from adding the atomization energy AE to the experimental 298 K heats of formation of the atoms. Inspection of Figure 10.1 indicates that this will differ from the rigid-rotor-hannonic-oscillator computed result by ZPVE and the differential thermal contributions to the enthalpy of the molecule compared to the atoms. [Pg.375]

The unique mechanical and structural properties of crystals necessitate the application of special experimental methods for the investigation of thd chemical kinetics of solids. In principle, all the physical parameters of substances involved in a chemical process can be used to follow the kinetics. These processes normally occur at high temperatures since they need thermal activation. Conventionally, the outcome of a solid state reaction experiment is inspected only after quenching. However, the quenching process is prone to alter many properties of the system, which explains the ambiguous results often found in the studies of solid state kinetics. [Pg.393]

The phase equilibria and diagrammatic structures in a two-component system are illustrated in Figure 7 (12). The phase diagrams have often been determined by inspection with the naked eye. More exact methods include x-ray and NMR analysis, density measurements, separation by high-speed centrifugation or differential thermal analysis. [Pg.25]

Distillation is also a means by which the character, especially the sulfur content, of a residuum may be adjusted. For example, inspections of various crude oil residua (Table 7-4) show that, for any particular crude oil, the vacuum residuum is virtually always higher in sulfur than an atmospheric residuum from the same crude oil. Thus, although distillation is the usual primary means by which a crude oil is processed, it may be completely bypassed in the case of an extremely heavy crude oil in favor of whole-crude processing by any of the more suitable thermal methods. [Pg.271]

Among the numerous well-known aging methods, such as the oxygen-uptake test, the U-tube test, the use of differential thermal analyses to indicate the oxidation exotherm, oven aging proved to be one of the most versatile methods. Not only can many specimens of any size and shape be tested simultaneously, but samples can also be withdrawn at convenient intervals for inspection. [Pg.254]

Thermal transmission methods are relatively new techniques for adhesive inspection. Heat flow is determined by monitoring the surface temperature of a test piece a short time immediately after external heating or cooling has been applied. Subsurface anomalies alter the heat flow pattern and, thereby, affect the surface temperature. The surface temperature difference can be detected by thermometers, thermocouples, or heat-sensitive coatings. Liquid crystals applied to the joint can make voids visible if the substrate is heated. [Pg.459]

It is easily seen by inspection that the biorthogonal basis set definition (3.55) cmnddes with the definifion (3.18) ven in the discussion of the Lanczos method. We recall that the dynamics of operators (liouville equations) or probabilities (Fokker-Planck equations) have a mathematical structure similar to Eq. (3.29) and can thus be treated with the same techniques (see, e.g., Chapter 1) once an appropriate generalization of a scalar product is performed. For instance, this same formalism has been successfully adopted to model phonon thermal baths and to include, in principle, anharmonicity effects in the interesting aspects of lattice dynamics and atom-solid collisions. ... [Pg.156]

Reaction of 216 with ethoxycarbonylmethylidene triphenylphosphorane gave 233, which was successfully cyclized to 238 (81MI2 87H2101) (Scheme 49). This reaction is a general method for synthesizing pyridazi-nones. The stereochemical outcome of the reaction of 216 with the phosphorane was found to afford the trans isomer 233, as anticipated from a Wittig reaction. Inspection of models indicated this isomer could not be cyclized. Its cyclization could be achieved experimentally as a consequence of the thermal preisomerization of 233 into the cis isomer 236, which led to its facile cyclization to 238. [Pg.287]

Thus, we take advantage of the accuracy, robustness and efficiency of the direct problem solution, to tackle the associated inverse heat transfer problem analysis [26, 27] towards the simultaneous estimation of momentum and thermal accommodation coefficients in micro-channel flows with velocity slip and temperature jump. A Bayesian inference approach is adopted in the solution of the identification problem, based on the Monte Carlo Markov Chain method (MCMC) and the Metropolis-Hastings algorithm [28-30]. Only simulated temperature measurements at the external faces of the channel walls, obtained for instance via infrared thermography [30], are used in the inverse analysis in order to demonstrate the capabilities of the proposed approach. A sensitivity analysis allows for the inspection of the identification problem behavior when the external wall Biot number is also included among the parameters to be estimated. [Pg.40]


See other pages where Thermal inspection methods is mentioned: [Pg.9]    [Pg.9]    [Pg.153]    [Pg.236]    [Pg.259]    [Pg.259]    [Pg.265]    [Pg.1200]    [Pg.798]    [Pg.419]    [Pg.34]    [Pg.357]    [Pg.66]    [Pg.179]    [Pg.40]    [Pg.897]    [Pg.418]    [Pg.75]    [Pg.510]    [Pg.136]    [Pg.425]    [Pg.149]    [Pg.149]    [Pg.150]    [Pg.581]    [Pg.394]    [Pg.897]    [Pg.1472]    [Pg.885]    [Pg.538]    [Pg.476]   