Inlet floor

In some cases, it is impractical to use a plenum chamber under the constriction plate. This condition arises when a flammable or explosive mixture of gases is being introduced to the reactor. One solution is to pipe the gases to a multitude of individual gas inlets in the floor of the reactor. In this way it may be possible to maintain the gas velocities in the pipes above the flame velocity or to reduce the volume of gas in each pipe to the point at which an explosion can be safely contained. Another solution is to provide separate inlets for the different gases and depend on mixing in the fluidized bed. The inlets should be fairly close to one another, as lateral gas mixing in fluidized beds is poor. [Pg.1566]

It was found most advantageous to run in the liquid ammonia from the commercial cylinder, laid on the floor with the foot raised slightly, and connected to the gas inlet tube with rubber tubing approximately 1 cm. in diameter. The large excess of liquid ammonia used obviates the need of a dry ice-acetone cooling bath and permits a reasonably rapid formation of sodium amide. [Pg.69]

Local ventilation is often a very important part of the ventilation system, both in function and in construction, which makes a specific definition difficult. In addition to the above definitions it can be defined as ventilation of a separate volume inside a large room, as opposed to general ventilation, which is for the complete room or building. One problem with this definition is that local ventilation systems could function as localized ventilation in one surrounding and as general ventilation in another surrounding e.g., a ceiling inlet combined with floor exhaust is a local ventilation system in a... [Pg.809]

These systems can be inside large halls and may have no fixed limits for their influence, except for some parts of the system (inlet device surface, etc.) They can also be situated inside small rooms, where walls, floors, and ceilings are the natural boundaries. The systems usually consist of one exhaust hood and one supply inlet, which interact. There are also special combinations, as two or more inlets and one exhaust hood, or one supply inlet and two or more exhausts. All of these combinations need careful design and an accurate relation between supply and exhaust flow rates and velocities. Some systems also need stable temperature conditions to function properly. All combinations are dependent on having a defined contaminant concentration in the inlet air. This usually implies clean supply air, but some systems may use recirculated air with or without cleaning. [Pg.935]

A wide air curtain is usually directed downward from above. The air is blown along the width of the entire door and the jet has a large depth. The ex haust, which could be connected to the inlet (recirculation), is then situated in the floor. The supply air is usually heated, by a heat regenerator, to increase the comfort of people passing through the opening. [Pg.1009]

FIGURE 11.13 The total age. There are two inlets at the ceiling and two exits at the sidewalls near the floor. (Reprinted from Building and Environmem. vot. 32. S.-H. Peng. S. Hoimberg, and L Oar/idson. "On the Assessment of Ventilation Performance witfi the Aid of Numerical Simulations," pp. 497-SOB. 1997, with permission from Elsevier Science.)... [Pg.1047]

We have used H = 3 m, = 0.455 rnys. The inlet (height h) is located at the left-side wall adjacent to the ceiling, and a wall jet is formed below the ceiling. The exit is located at the right-side wall near the floor (height t). [Pg.1049]

If inlet weirs are used they should have at least two slots %-in. by 1-in. flush with the tray floor to aid in flushing out any trapped sediment or other material. There should also be weep or drain holes below the downcomer to drain the weir seal area. The size should be set by the type of service, but a minimum of M-in. is recommended. [Pg.134]

For trays with inlet weirs, seal values may be reduced if necessary for high flow conditions. A good tray design is centered about a 1.5-in. clearance distance between tray floor and bottom of downcomer edge. [Pg.168]

Inlet weir height above tray floor, 3 in. [Pg.171]

Cross-section flow area, minimum, of down-pipe clearance area between tray floor and down-pipe bottom edge, or up-flow area between outer circumference dotvn-pipe and any inlet tray w eir, in. Individual hole area per hole on sieve tray, in. Riser inside cross-section area per riser, in. Reversal area per cap assembly, in. ... [Pg.221]

Gas boosters may be fitted with motor enclosures or designed to operate at lower rotating speeds. Alternatively, they may be housed in an acoustic enclosure within the boiler house. The booster and drive unit can be supplied with anti-vibration mountings to isolate it from the floor or steelwork and flexible bellows fitted to the gas inlet and outlet connections. [Pg.367]

Unit heaters A unit with a large propeller or cenhifugal fan to give high air volume and wide throws. Louvers direct the air flow in the direction required. May be ceiling mounted, discharging vertically or horizontally or floor mounted. Can be used with fresh air Rapid response to conhol by individual thermostat by use of multi-speed motors rapid warm-up available on intermittent systems Altered fresh air inlet facility. Electric supply required for each individual unit. 3 to 300 kW. [Pg.414]

Make no excuse for checking whether the sun shines on the thermostats or someone has washed the floor. Another common occurrence is that while the room is not being controlled as specified, the plant appears to be operating correctly. Here a series of simultaneous readings of air flows and wet and dry bulb temperatures should be taken around the whole of the air circuit - on and off coil, condition after fan, condition at inlet grilles, etc. Referring these to a psychrometric chart will usually indicate where the fault or leak lies. [Pg.453]

The large scale of slurry ice storage system is installed in Kyoto station building. The building of 237,689 m2 floor area is air conditioned with 4 absorption chillers of 5,830 kW and slurry ice tank of 1,700 m3. Sub cooled water is projected into tube shape inlet where ice is made by release from sub cooling state. Slurry ice is conveyed to separate tanks through a pipe (Figure 192). [Pg.342]

Drainage patterns should minimize pooling of runoff near equipment and prevent drainage from unpaved areas from entering floor drain inlets in paved areas. [Pg.241]

Loading/ unloading freeze dryer Room no. Inlet and outlet of conveyor, P. D. door, tray, curtain Conveyor (five positions), tray, moving parts (two positions), each curtain, tray (five positions), P.D. door, inner floor 1 CPU... [Pg.776]

Notes 1) The structure, consisting of the plenum chamber filter, shall be of such design that it can be supported by means of four (4) steel columns, one (1) at each corner. 2) Plenun chamber shall be of sufficient strength bracing to prevent wall, floor or ceiling from pulsating or oscillating. 3) For ammonia/urea plants or other installations with ammonia in the atmosphere, no copper, alianinum or their alloys shall be used for parts exposed to the air. 4) Seals filter material shall be resistant to vapors present in the inlet air (ammonia, hydrocarbons, etc.). 5) Unit shall be completely assembled and shipped as one unit. 6) Instruments controls to be conpletely piped and wired. 7) Outlet connection screen (0.25 in.) (6 mm) wire mesh, with back up bars to withstand seven (7) psi/0.5 kg/cm Press, across the screen. [Pg.713]

Because of the physical size of the reactor, it is normally mounted with the top of the reactor at a mezzanine floor level. This allows easy access to the inlet ports. The reactor can be mounted at this point on a number of load cells. The load cells must be of such capacity to take the whole weight of the reactor when it is full of prepolymer. In this case, all connectors to the reactor must be flexible. [Pg.56]

The need for positively sealing the downcomer is determined in this phase. This could be achieved by installing an inlet weir, which is a weir installed at the tray inlet to keep the downcomer outlet immersed in liquid. A similar device, which extends below the tray floor, is a seal pan (Fig. 17). Both devices provide positive assurance against vapor rising up the downcomer, but they may also trap solids and dirt and cause blockage. A seal pan must always be used in the downcomer from the bottom tray otherwise there is nothing to prevent vapor from rising up the bottom downcomer. [Pg.26]

Ribbon blenders. Price includes standard floor-mounted support, baffled shell cover, antifriction pillow blocks mounted on outboard bearing shelves, stuffing box, flanged inlet opening, and lever-operated discharge gate. [Pg.557]


See other pages where Inlet floor is mentioned: [Pg.354]    [Pg.354]    [Pg.1589]    [Pg.1976]    [Pg.588]    [Pg.999]    [Pg.1005]    [Pg.1114]    [Pg.177]    [Pg.180]    [Pg.442]    [Pg.1282]    [Pg.545]    [Pg.36]    [Pg.114]    [Pg.114]    [Pg.252]    [Pg.9]    [Pg.20]    [Pg.241]    [Pg.416]    [Pg.98]    [Pg.52]    [Pg.1011]    [Pg.51]    [Pg.467]    [Pg.426]    [Pg.466]    [Pg.298]    [Pg.246]   
See also in sourсe #XX -- [ Pg.354 ]