Infrared absorbance, integrated

Recent work in our laboratory has shown that Fourier Transform Infrared Reflection Absorption Spectroscopy (FT-IRRAS) can be used routinely to measure vibrational spectra of a monolayer on a low area metal surface. To achieve sensitivity and resolution, a pseudo-double beam, polarization modulation technique was integrated into the FT-IR experiment. We have shown applicability of FT-IRRAS to spectral measurements of surface adsorbates in the presence of a surrounding infrared absorbing gas or liquid as well as measurements in the UHV. We now show progress toward situ measurement of thermal and hydration induced conformational changes of adsorbate structure. The design of the cell and some preliminary measurements will be discussed. [Pg.435]

The infrared absorbance spectra were recorded at room temperature on a Fourier transform spectrophotometer (Biucker I.F.S. 110) with a resolution of 4 cm To compare the integrated adsorbances of the various samples the weight of the pellet and the Pd content were considered. The samples were placed in a heatable cell where the catalysts were treated "in situ". Different kinds of experiments were carried out ... [Pg.347]

Figure 27-7 Combustion analyzer that uses infrared absorbance to measure C02, H20, and S02 and thermal conductivity to measure N2. Three separate infrared cells in series are equipped with filters that isolate wavelengths absorbed by one of the products. Absorbance is integrated over time as the combustion product mixture is swept through each cell. [Courtesy Leco Corp., st. Joseph, Ml.)... Figure 27-7 Combustion analyzer that uses infrared absorbance to measure C02, H20, and S02 and thermal conductivity to measure N2. Three separate infrared cells in series are equipped with filters that isolate wavelengths absorbed by one of the products. Absorbance is integrated over time as the combustion product mixture is swept through each cell. [Courtesy Leco Corp., st. Joseph, Ml.)...
C02 in the gas phase can be determined by means of its significant infrared absorbance (Fig. 10) at wave lengths (A) < 15 pm, particularly at 4.3 pm [289], or by acoustic means. Integrated photoacoustic spectroscopy and magnetoacoustic (PAS/MA) technology for combined C02 and 02 analysis has rapid response time and a small sample volume is sufficient. The acoustic methods are accurate, stable over long periods and very simple to use. [Pg.13]

Fig. 28. Integrated infrared absorbance of the Si-H2 stretch and scissor modes as a function of (a) annealing temperature, and (b) time at 580 K [113],... Fig. 28. Integrated infrared absorbance of the Si-H2 stretch and scissor modes as a function of (a) annealing temperature, and (b) time at 580 K [113],...
Frequency-Modulation Spectroscopy. Frequency-modulation spectroscopy (tins) is a high sensitivity null-background infrared technique for measuring absorbances down to 10 with fast acquisition speeds. Fms involves frequency-modulating a laser source at COq to produce a carrier frequency having sidebands at cJq where is an integral multiple of the modulation frequency. Dye lasers and many other single-line sources can... [Pg.321]

One cm3 of the reactant/product/catalyst mixture was sampled periodically during the reaction for the transmission infrared analysis (Nicolet Magna 550 Series II infrared spectrometer with a MCT detector). The concentrations of reactants and products were obtained by multiplying integrated absorbance of each species by its molar extinction coefficient. The molar extinction coefficient was determined from the slope of a calibration curve, a plot of the peak area versus the number of moles of the reagent in the IR cell. The reaction on each catalyst was repeated and the relative error for the carbamate yield measured by IR is within 5%. [Pg.476]

Therefore quantum fluctuations in B<3) are accompanied by fluctuations in the transverse electric field. The ultraviolet divergence is probably unimportant [17] because of the co 2 dependence of the fluctuation. The infrared divergence is also damped statistically. The divergences in U(l) electrodynamics [6] can exist as a subset of 0(3) electrodynamics and can be absorbed into integrals that involve photon loop processes associated with quantum fluctuations in B(3 ... [Pg.155]

When light is directed onto a sample it may either be transmitted or reflected. Hence, one can obtain the spectra by either transmission or reflection. Since some of the light is absorbed and the remainder is reflected, study of the diffuse reflected light can be used to measure the amount absorbed. However, the low efficiency of this diffuse reflectance process makes it extremely difficult to measure 120) and it was speculated that infrared diffuse reflection measurements would be futile 120). Initially, an integrating sphere was used to capture all of the reflected light121) but more recently improved diffuse reflectance cells have been designed which allow the measurement of diffuse reflectance spectra using FT-IR instrumentation 122). [Pg.110]


See other pages where Infrared absorbance, integrated is mentioned: [Pg.171]    [Pg.299]    [Pg.230]    [Pg.778]    [Pg.57]    [Pg.435]    [Pg.290]    [Pg.1286]    [Pg.292]    [Pg.448]    [Pg.499]    [Pg.542]    [Pg.114]    [Pg.395]    [Pg.82]    [Pg.372]    [Pg.191]    [Pg.770]    [Pg.61]    [Pg.205]    [Pg.36]    [Pg.292]    [Pg.145]    [Pg.233]    [Pg.212]    [Pg.219]    [Pg.181]    [Pg.529]    [Pg.288]    [Pg.384]    [Pg.3808]    [Pg.292]    [Pg.311]    [Pg.140]    [Pg.1253]    [Pg.564]    [Pg.5]    [Pg.354]   